Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 166

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Platelet-Rich Plasma for Arthroscopic Repair of Medium to Large Rotator Cuff Tears: A Randomized Controlled Trial

Jo, Chris Hyunchul, Shin, Ji Sun, Shin, Won Hyoung, Lee, Seung Yeon, Yoon, Kang Sup, Shin, Sue · 2015 · The American Journal of Sports Medicine

Abstract

Background: Two main questions about the use of platelet-rich plasma (PRP) for regeneration purposes are its effect on the speed of healing and the quality of healing. Despite recent numerous studies, evidence is still lacking in this area, especially in a representative patient population with medium to large rotator cuff tears. Purpose: To assess the efficacy of PRP augmentation on the speed and quality of healing in patients undergoing arthroscopic repair for medium to large rotator cuff tears. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: A total of 74 patients scheduled for arthroscopic repair of medium to large rotator cuff tears were randomly assigned to undergo either PRP-augmented repair (PRP group) or conventional repair (conventional group). In the PRP group, 3 PRP gels (3 × 3 mL) were applied to each patient between the torn end and the greater tuberosity. The primary outcome was the Constant score at 3 months after surgery. Secondary outcome measures included the visual analog scale (VAS) for pain, range of motion (ROM), muscle strength, overall satisfaction and function, functional scores, retear rate, and change in the cross-sectional area (CSA) of the supraspinatus muscle. Results: There was no difference between the 2 groups in the Constant score at 3 months ( P > .05). The 2 groups had similar results on the VAS for pain, ROM, muscle strength, overall satisfaction and function, and other functional scores (all P > .05) except for the VAS for worst pain ( P = .043). The retear rate of the PRP group (3.0%) was significantly lower than that of the conventional group (20.0%) ( P = .032). The change in 1-year postoperative and immediately postoperative CSAs was significantly different between the 2 groups: –36.76 ± 45.31 mm 2 in the PRP group versus −67.47 ± 47.26 mm 2 in the conventional group ( P = .014). Conclusion: Compared with repairs without PRP augmentation, the current PRP preparation and application methods for medium to large rotator cuff repairs significantly improved the quality, as evidenced by a decreased retear rate and increased CSA of the supraspinatus, but not the speed of healing. However, further studies may be needed to investigate the effects of PRP on the speed of healing without risking the quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0363546515587081

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Jo, C. H., Shin, J. S., Shin, W. H., Lee, S. Y., Yoon, K. S., & Shin, S.
Venue
The American Journal of Sports Medicine
Published
2015-05-26
Volume
43
Issue
9
Pages
2102-2110
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2123394378
Cited by
166
References
2
FWCI
16.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Platelet-Rich Plasma for Arthroscopic Repair of Medium to Large Rotator Cuff Tears: A Randomized Controlled Trial. https://app.cochat.ai/papers/10.1177/0363546515587081
The paper
Jo, C. H., Shin, J. S., Shin, W. H., Lee, S. Y., Yoon, K. S., & Shin, S. (2015). Platelet-Rich Plasma for Arthroscopic Repair of Medium to Large Rotator Cuff Tears: A Randomized Controlled Trial. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546515587081

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.