CoChat

Graft Diameter as a Predictor for Revision Anterior Cruciate Ligament Reconstruction and KOOS and EQ-5D Values: A Cohort Study From the Swedish National Knee Ligament Register Based on 2240 Patients

Snaebjörnsson, Thorkell, Hamrin Senorski, Eric, Ayeni, Olufemi R., Alentorn-Geli, Eduard, Krupic, Ferid, Norberg, Fredrik, Karlsson, Jón, Samuelsson, Kristian · 2017 · The American Journal of Sports Medicine
Cited by 183

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Background: Anterior cruciate ligament (ACL) reconstruction (ACLR) using a hamstring tendon (HT) autograft is an effective and widespread method. Recent studies have identified a relationship between the graft diameter and revision ACLR. Purpose: To evaluate the influence of the graft diameter on revision ACLR and patient-reported outcomes in patients undergoing primary ACLR using HT autografts. Study Design: Cohort study; Level of evidence, 2. Methods: A prospective cohort study was conducted using the Swedish National Knee Ligament Register (SNKLR) involving all patients undergoing primary ACLR using HT autografts. Patients with graft failure who needed revision surgery (cases) were compared with patients not undergoing revision surgery (controls). The control group was matched for sex, age, and graft fixation method in a 3:1 ratio. Conditional logistic regression was performed to produce odds ratios and 95% CIs. Univariate linear regression analyses were performed for patient-related outcomes. The Knee injury and Osteoarthritis Outcome Score (KOOS) and EuroQol 5 dimensions questionnaire (EQ-5D) values were obtained. Results: A total of 2240 patients were included in which there were 560 cases and 1680 controls. No significant differences between the cases and controls were found for sex (52.9% male), mean age (21.7 years), and femoral and tibial fixation. The mean graft diameter for the cases was 8.0 ± 0.74 mm and for the controls was 8.1 ± 0.76 mm. In the present cohort, the likelihood of revision surgery for every 0.5-mm increase in the HT autograft diameter between 7.0 and 10.0 mm was 0.86 (95% CI, 0.75-0.99; P = .03). Univariate linear regression analysis found no significant regression coefficient for the change in KOOS or EQ-5D values. Conclusion: In a large cohort of patients after primary ACLR with HT autografts, an increase in the graft diameter between 7.0 and 10.0 mm resulted in a 0.86 times lower likelihood of revision surgery with every 0.5-mm increase. This study provides further evidence of the importance of the HT autograft size in intraoperative decision making.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/0363546517704177

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 183

Metadata

Authors
Snaebjörnsson, T., Hamrin Senorski, E., Ayeni, O. R., Alentorn-Geli, E., Krupic, F., Norberg, F., Karlsson, J., & Samuelsson, K.
Venue
The American Journal of Sports Medicine
Published
2017-05-01
Volume
45
Issue
9
Pages
2092-2097
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2611558877
Cited by
183
References
23
FWCI
13.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Graft Diameter as a Predictor for Revision Anterior Cruciate Ligament Reconstruction and KOOS and EQ-5D Values: A Cohort Study From the Swedish National Knee Ligament Register Based on 2240 Patients. https://app.cochat.ai/papers/10.1177/0363546517704177
The paper
Snaebjörnsson, T., Hamrin Senorski, E., Ayeni, O. R., Alentorn-Geli, E., Krupic, F., Norberg, F., Karlsson, J., & Samuelsson, K. (2017). Graft Diameter as a Predictor for Revision Anterior Cruciate Ligament Reconstruction and KOOS and EQ-5D Values: A Cohort Study From the Swedish National Knee Ligament Register Based on 2240 Patients. The American Journal of Sports Medicine. https://doi.org/10.1177/0363546517704177

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.