The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Factors affecting the region of most isometric femoral attachments: Part I: The posterior cruciate ligament
Abstract
We measured how the distance between selected tibial and femoral attachments of the PCL changes with knee flexion in six intact cadaver knees. The femoral location was the primary determinant of whether the distance increased, decreased, or remained nearly constant. The proximal-distal location of a fiber's femoral attachment had a stronger effect than had the anterior-posterior location. The tibial location had only a small statistically significant effect. These results suggest that the func tion of fibers within the PCL is determined primarily by their femoral attachment location. We determined all femoral attachments whose tibio femoral distance changed 0, 2, 4, 6, 8, and 10 mm during flexion from 0° to 90°. No absolutely isometric point existed. Attachments whose separation distance changed less than 2 mm formed a bullet-shaped region whose base was against the roof of the intercondylar notch and whose nose pointed posteriorly and slightly distally. The axis of the "bullet" was near the proximal edge of the femoral insertion of the PCL. Along the axis, anterior attachments, located near the roof of the intercondylar notch, were more isometric than were posterior attachments, located near the cartilage. At tachments located distal to the axis moved away from the tibial insertion of the PCL when the knee was flexed. The more distal the femoral attachment, the larger the increase in tibiofemoral distance that occurred with flexion. The opposite was true of attachments proximal to the 2 mm region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Prime Static Stabilizer of the Medial Side of the Knee
WARREN, L. F., MARSHALL, J. L., & GIRGIS, F. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456040-00002 · Cited by 278
Cited by
Hefzy, M. S., Grood, E. S., & Noyes, F. R. (1989) · The American Journal of Sports Medicine · doi:10.1177/036354658901700210 · Cited by 450
Self-citationRace, A., & Amis, A. A. (1998) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.80b1.7453 · Cited by 265
Li, G., DeFrate, L. E., Sun, H., & Gill, T. J. (2004) · The American Journal of Sports Medicine · doi:10.1177/0363546503262175 · Cited by 182
Metadata
- Authors
- Grood, E. S., Hefzy, M. S., & Lindenfield, T. N.
- Venue
- The American Journal of Sports Medicine
- Publisher
- SAGE Publications
- Published
- 1989-03
- Volume
- 17
- Issue
- 2
- Pages
- 197-207
- ISSN
- 0363-5465 (ISSN-L)
- 1552-3365
- OpenAlex
- W3170610168
- Cited by
- 174
- References
- 1
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors affecting the region of most isometric femoral attachments: Part I: The posterior cruciate ligament. https://app.cochat.ai/papers/10.1177/036354658901700209
- The paper
- Grood, E. S., Hefzy, M. S., & Lindenfield, T. N. (1989). Factors affecting the region of most isometric femoral attachments: Part I: The posterior cruciate ligament. The American Journal of Sports Medicine. https://doi.org/10.1177/036354658901700209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.