Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 339

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

The Effect of Allograft Meniscal Replacement on Intraarticular Contact Area and Pressures in the Human Knee: A Biomechanical Study

Paletta, George A., Manning, Tim, Snell, Edward, Parker, Richard, Bergfeld, John·1997·The American Journal of Sports Medicine

Abstract

To define the biomechanical effects of total lateral meniscectomy and of subsequent lateral meniscal al lograft replacement on load transmission and distribu tion across the human knee, we mounted 10 fresh- frozen, young human cadaveric knees on a mechanical testing system. Peak pressure and contact area profiles were determined at 0°, 30°, and 60° of knee flexion using pressure-sensitive film and a den sitometer. Load transmission profiles were determined for each knee in a sequential test order: 1)intact knee, 2) after lateral meniscectomy, 3) after implantation of size-matched meniscal allograft fixed with bone plugs, and 4) after release of the anterior and posterior horn attachments of the allograft. Total lateral meniscec tomy resulted in a 45% to 50% decrease in total con tact area. Allograft replacement increased total contact area by 42% to 65% as compared with total meniscec tomy at all flexion angles. After release of the anterior and posterior horn attachments, contact area was identical to that after total meniscectomy. Total lateral meniscectomy resulted in a 235% to 335% increase in peak local contact pressure. Allograft replacement de creased these pressures by 55% to 65% at all flexion angles, but they remained significantly greater than those in the intact state. After release of the anterior and posterior horn attachments, contact pressures were identical to those after total meniscectomy. Com pared with total meniscectomy, meniscal allograft transplantation significantly increases contact area and decreases peak local contact pressures, but any bio mechanical advantages are lost without bone plug fix ation of the anterior and posterior horns.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/036354659702500519

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

Metadata

Authors
Paletta, G. A., Manning, T., Snell, E., Parker, R., & Bergfeld, J.
Venue
The American Journal of Sports Medicine
Published
1997-09
Volume
25
Issue
5
Pages
692-698
ISSN
  • 0363-5465 (ISSN-L)
  • 1552-3365
OpenAlex
W2144456209
Cited by
339
References
31
FWCI
8.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effect of Allograft Meniscal Replacement on Intraarticular Contact Area and Pressures in the Human Knee: A Biomechanical Study. https://app.cochat.ai/papers/10.1177/036354659702500519
The paper
Paletta, G. A., Manning, T., Snell, E., Parker, R., & Bergfeld, J. (1997). The Effect of Allograft Meniscal Replacement on Intraarticular Contact Area and Pressures in the Human Knee: A Biomechanical Study. The American Journal of Sports Medicine. https://doi.org/10.1177/036354659702500519

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.