Determination of Time Delay between Blood and Interstitial Adipose Tissue Glucose Concentration Change by Microdialysis in Healthy Volunteers
The DOI matches its Crossref record.
Abstract
For the development and use of subcutaneous glucose sensors it is important to know the time lag between changes in blood glucose and subcutaneous interstitial glucose concentration. To determine the time lag we inserted a microdialysis probe into the abdominal subcutaneous adipose tissue of healthy volunteers (n =19) and performed oral glucose tolerance tests (n=39) over a 7-day period. After correction for the microdialysis system time lag, we compared the change in dialysate glucose concentration with the capillary blood glucose concentration. We found no significant delay time between a change in capillary blood glucose concentration and subcutaneous interstitial fluid glucose concentration using the Mann-Whitney test. The substantial interindividual variation of glucose recovery and the changing recovery in time makes it difficult to draw unambiguous conclusions about the exact physiological time lag. Based on the present experimental findings and theoretical calculations of glucose transport in adipose tissue, the physiological lag time is short and negligible compared to the system delay time of a glucose sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“fall in IG would precede fall in BG [196], [212].”
Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234
The artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
Burnett, D. R., Huyett, L. M., Zisser, H. C., Doyle, F. J., & Mensh, B. D. (2014) · Diabetes · doi:10.2337/db13-1649 · Cited by 52
Alternative-Site Blood Glucose Measurement at the Abdomen
van der Valk, P. R., van der Schatte Olivier-Steding, I., Wientjes, K.-J. C., Schoonen, A. J., & Hoogenberg, K. (2002) · Diabetes Care · doi:10.2337/diacare.25.11.2114 · Cited by 15
Self-citation
Metadata
- Authors
- Wientjes, K. J. C., & Schoonen, A. J. M.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 2001-12
- Volume
- 24
- Issue
- 12
- Pages
- 884-889
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W2411531654
- Cited by
- 42
- References
- 0
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Time Delay between Blood and Interstitial Adipose Tissue Glucose Concentration Change by Microdialysis in Healthy Volunteers. https://app.cochat.ai/papers/10.1177/039139880102401213
- The paper
- Wientjes, K. J. C., & Schoonen, A. J. M. (2001). Determination of Time Delay between Blood and Interstitial Adipose Tissue Glucose Concentration Change by Microdialysis in Healthy Volunteers. The International Journal of Artificial Organs. https://doi.org/10.1177/039139880102401213
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.