Glucose Sensing in the Peritoneal Space Offers Faster Kinetics Than Sensing in the Subcutaneous Space

Open access

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

The paramount goal in the treatment of type 1 diabetes is the maintenance of normoglycemia. Continuous glucose monitoring (CGM) technologies enable frequent sensing of glucose to inform exogenous insulin delivery timing and dosages. The most commonly available CGMs are limited by the physiology of the subcutaneous space in which they reside. The very same advantages of this minimally invasive approach are disadvantages with respect to speed. Because subcutaneous blood flow is sensitive to local fluctuations (e.g., temperature, mechanical pressure), subcutaneous sensing can be slow and variable. We propose the use of a more central, physiologically stable body space for CGM: the intraperitoneal space. We compared the temporal response characteristics of simultaneously placed subcutaneous and intraperitoneal sensors during intravenous glucose tolerance tests in eight swine. Using compartmental modeling based on simultaneous intravenous sensing, blood draws, and intraarterial sensing, we found that intraperitoneal kinetics were more than twice as fast as subcutaneous kinetics (mean time constant of 5.6 min for intraperitoneal vs. 12.4 min for subcutaneous). Combined with the known faster kinetics of intraperitoneal insulin delivery over subcutaneous delivery, our findings suggest that artificial pancreas technologies may be optimized by sensing glucose and delivering insulin in the intraperitoneal space.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2337/db13-1649

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 A: Sample raw data from an intravenous (IV) glucose challenge in one pig. Unfiltered data were collected every second (1 Hz). B: Calculation of latency (time to half-maximum) and recovery (percent return to baseline at 35 min) for a sample intraperitoneal (IP) trace. Data are filtered using a 1-min sliding window average. Baseline is determined by the average reading for the 3 min before the onset of the glucose challenge. As with the baseline, the value at 35 min is also determined by a 3-min average (33.5 to 36.5 min). IA, intraarterial; SQ, subcutaneous.
Figure 1 A: Sample raw data from an intravenous (IV) glucose challenge in one pig. Unfiltered data were collected every second (1 Hz). B: Calculation of latency (time to half-maximum) and recovery (percent return to baseline at 35 min) for a sample intraperitoneal (IP) trace. Data are filtered using a 1-min sliding window average. Baseline is determined by the average reading for the 3 min before the onset of the glucose challenge. As with the baseline, the value at 35 min is also determined by a 3-min average (33.5 to 36.5 min). IA, intraarterial; SQ, subcutaneous.CC BY-NC-ND · PubMed Central
Figure 2 Comparison of response speed between intraperitoneal and subcutaneous sensors. A: Latency (time to half-maximum) is plotted for intraperitoneal (IP) vs. subcutaneous (SQ) for all 13 challenges across eight pigs. The diagonal line represents intraperitoneal = subcutaneous; thus, points below the line indicate intraperitoneal is faster than subcutaneous. B: Recovery (percent return to baseline at 35 min, see Fig. 1B for definition) is plotted for intraperitoneal vs. subcutaneous for all 13 challenges across eight pigs. The diagonal line of identity represents intraperitoneal = subcutaneous; thus, points above the line indicate intraperitoneal sensor readings returning to baseline by a greater amount than subcutaneous sensors returned to baseline for the same IVGTT challenge.
Figure 2 Comparison of response speed between intraperitoneal and subcutaneous sensors. A: Latency (time to half-maximum) is plotted for intraperitoneal (IP) vs. subcutaneous (SQ) for all 13 challenges across eight pigs. The diagonal line represents intraperitoneal = subcutaneous; thus, points below the line indicate intraperitoneal is faster than subcutaneous. B: Recovery (percent return to baseline at 35 min, see Fig. 1B for definition) is plotted for intraperitoneal vs. subcutaneous for all 13 challenges across eight pigs. The diagonal line of identity represents intraperitoneal = subcutaneous; thus, points above the line indicate intraperitoneal sensor readings returning to baseline by a greater amount than subcutaneous sensors returned to baseline for the same IVGTT challenge.CC BY-NC-ND · PubMed Central
Figure 3 Sample of compartmental modeling fit to data. This plot shows an example of the model-fitting process for a single challenge, using glucometer measurements as the input. Shown on the plot are the experimental measurements made by the intraperitoneal (IP) and subcutaneous (SQ) sensors, as well as the model predicted output for each sensor model. The goodness-of-fit values for the intraperitoneal and subcutaneous models shown were 89% and 90%, with time constants of 1.7 and 13.1 min, respectively.
Figure 3 Sample of compartmental modeling fit to data. This plot shows an example of the model-fitting process for a single challenge, using glucometer measurements as the input. Shown on the plot are the experimental measurements made by the intraperitoneal (IP) and subcutaneous (SQ) sensors, as well as the model predicted output for each sensor model. The goodness-of-fit values for the intraperitoneal and subcutaneous models shown were 89% and 90%, with time constants of 1.7 and 13.1 min, respectively.CC BY-NC-ND · PubMed Central
Figure 4 Comparison of kinetic modeling–based response speed between intraperitoneal and subcutaneous sensors for all 13 challenges. The diagonal line represents intraperitoneal = subcutaneous; thus, points below the line indicate intraperitoneal time constants smaller (faster) than subcutaneous.
Figure 4 Comparison of kinetic modeling–based response speed between intraperitoneal and subcutaneous sensors for all 13 challenges. The diagonal line represents intraperitoneal = subcutaneous; thus, points below the line indicate intraperitoneal time constants smaller (faster) than subcutaneous.CC BY-NC-ND · PubMed Central
Figure 5 Comparison of kinetic time constants between subcutaneous (SQ) and intraperitoneal (IP) sensors from models fit using three different input sources for vascular glucose concentration. The average ratio is shown, with error bars indicating the standard error. The number above the bar specifies the number of challenges that had a usable signal from that particular type of input. For each type of input, the average intraperitoneal time constant was less than half of the subcutaneous time constant from the same challenge. IA, intraarterial; IV, intravenous.
Figure 5 Comparison of kinetic time constants between subcutaneous (SQ) and intraperitoneal (IP) sensors from models fit using three different input sources for vascular glucose concentration. The average ratio is shown, with error bars indicating the standard error. The number above the bar specifies the number of challenges that had a usable signal from that particular type of input. For each type of input, the average intraperitoneal time constant was less than half of the subcutaneous time constant from the same challenge. IA, intraarterial; IV, intravenous.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 47 references

Cited by

See all 52

Metadata

Authors
Burnett, D. R., Huyett, L. M., Zisser, H. C., Doyle, F. J., & Mensh, B. D.
Affiliations
  • Theranova (United States) (US)
  • University of California, Santa Barbara (US)
  • Howard Hughes Medical Institute (US)
Corresponding author
Mensh, Brett D.
Venue
Diabetes
Published
2014-06-14
Volume
63
Issue
7
Pages
2498-2505
ISSN
  • 0012-1797 (ISSN-L)
  • 1939-327X
OpenAlex
W2162507602
Cited by
52
References
46
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 8 · 2018: 6 · 2017: 8 · 2016: 5 · 2015: 6 · 2014: 1
FWCI
5.37
Type
journal article
Language
en
Open access
Locations
  • Diabetes (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (R43DK093140, R43-DK-93140)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Pancreatic function and diabetes
Keywords
continuous glucose monitoring, type 1 diabetes, glucose kinetics, intravenous glucose tolerance test, compartmental modeling, artificial pancreas, pigs
MeSH terms
Animals, Ascitic Fluid, Diabetes Mellitus, Female, Glucose, Glucose Tolerance Test, Insulin, Insulin Infusion Systems, Kinetics, Peritoneal Cavity, Swine, Blood Glucose Self-Monitoring, Biosensing Techniques, Pancreas, Artificial, Subcutaneous Tissue

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glucose Sensing in the Peritoneal Space Offers Faster Kinetics Than Sensing in the Subcutaneous Space. https://app.cochat.ai/papers/10.2337/db13-1649
The paper
Burnett, D. R., Huyett, L. M., Zisser, H. C., Doyle, F. J., & Mensh, B. D. (2014). Glucose Sensing in the Peritoneal Space Offers Faster Kinetics Than Sensing in the Subcutaneous Space. Diabetes. https://doi.org/10.2337/db13-1649

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.