Artificial Tissues in Perfusion Culture
The DOI matches its Crossref record.
Abstract
In the stagnant environment of traditional culture dishes it is difficult to generate long term experiments or artificial tissues from human cells. For this reason a perfusion culture system with a stable supply of nutrients was developed. Human chondrocytes were seeded three-dimensionally in resorbable polymer fleeces. The cell-polymer tissues were then mounted in newly developed containers (W. W. Minuth et al, Biotechniques, 1996) and continuously perfused by fresh medium for 40 days. Samples from the effluate were analyzed daily, and the pH of the medium and glucose concentration remained stable during this period. The lactid acid concentration increased from 0,17 mg/ml to 0,35 mg/ml, which was influenced by the degradation of the resorbable polymer fibers used as three dimensional support material for the cells. This perfusion system proved to be reliable especially in long term cultures. Any components in the culture medium of the cells could be monitored without disturbances as caused by manual medium replacement. These results suggest the described perfusion culture system to be a valuable and convenient tool for many applications in tissue engineering, especially in the generation of artificial connective tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Perfusion Improves Tissue Architecture of Engineered Cardiac Muscle
Carrier, R. L., Rupnick, M., Langer, R., Schoen, F. J., Freed, L. E., & Vunjak-Novakovic, G. (2002) · Tissue Engineering · doi:10.1089/107632702753724950 · Cited by 323
Bioreactor design for tissue engineering
Pörtner, R., Nagel-Heyer, S., Goepfert, C., Adamietz, P., & Meenen, N. M. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.235 · Cited by 305
Tissue engineering: advances in in vitro cartilage generation
Risbud, M. V., & Sittinger, M. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)02016-4 · Cited by 268
Self-citationWu, M.-H., Chang, Y.-H., Liu, Y.-T., Chen, Y.-M., Wang, S.-S., Wang, H.-Y., Lai, C.-S., & Pan, T.-M. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.11.027 · Cited by 42
“Conversely, a perfusion cell culture can tackle this issue by continuously providing a cell culture system for nutrient supply andwaste removal, and hence can maintain a stable culture environment [21,22].”
Background
Metadata
- Authors
- Sittinger, M., Schultz, O., Keyszer, G., Minuth, W. W., & Burmester, G. R.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 1997-01
- Volume
- 20
- Issue
- 1
- Pages
- 57-62
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W2211464868
- Cited by
- 95
- References
- 0
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Artificial Tissues in Perfusion Culture. https://app.cochat.ai/papers/10.1177/039139889702000111
- The paper
- Sittinger, M., Schultz, O., Keyszer, G., Minuth, W. W., & Burmester, G. R. (1997). Artificial Tissues in Perfusion Culture. The International Journal of Artificial Organs. https://doi.org/10.1177/039139889702000111
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.