Non-Invasive Blood Glucose Monitoring by Means of near Infrared Spectroscopy: Methods for Improving the Reliability of the Calibration Models
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The feasibility of using near infrared reflection spectroscopy for non-invasive blood glucose monitoring is discussed. Spectra were obtained using a diode-array spectrometer with a fiberoptic measuring head with a wavelength ranging from 800 nm to 1350 nm. Calibration was performed using partial least-squares regression and radial basis function networks. The results of different methods used to evaluate the quality of the recorded spectra in order to improve the reliability of the calibration models, are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Regression and Outlier Detection
Rousseeuw, P. J., & Leroy, A. M. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/0471725382 · Cited by 5,609
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Reichard, P., Nilsson, B.-Y., & Rosenqvist, U. (1993) · New England Journal of Medicine · doi:10.1056/nejm199307293290502 · Cited by 1,202
Research works printed but not linked: 26
- 10.1007/BF01228130 · DOI · Paper page
- 10.1056/NEJM199309303291401 · DOI · Paper page
- Bott U., 1993, Diabetic Med, 11, 326
- 10.1007/BF00404077 · DOI
- 10.1177/039139889101400210 · DOI
- Jansson P.A., 1988, Amer J Physiol, 88, E118
- 10.1007/BF02221686 · DOI
- Kayashima S., 1991, IEEE Trans (BME), 38, 752
- 10.1023/A:1018926215306 · DOI
- 10.1007/BF02446645 · DOI
- Duncan A., A portable noninvasive blood glucose monitor
- Spanner G., 1996, Fresenius J Anal Chem, 3, 306, 10.1007/s0021663540306 · doi:10.1007/s0021663540306
- 10.1093/clinchem/38.9.1618 · DOI · Paper page
- Marbach R., 1993, VDI Reihe, 8
- 10.1366/0003702934415354 · DOI · Paper page
- Martens H., 1989, Multivariate calibration.
- Scholz V., 1992, Behandlungs- und Schulungsprogramm für Typ-I-Diabetiker.
- Heinemann L., 1993, Pharmakokinetik und Pharmakodynamik verschiedener Insulinpräparationen und Insulin-Analoga.
- MATLAB 4.3 for Windows.
- Demuth H., 1994, Neural network Toolbox 2 for use with Matlab, User's Guide.
- 10.1021/ac00162a020 · DOI · Paper page
- 10.1109/72.80341 · DOI · Paper page
- 10.1016/0169-7439(95)80039-C · DOI
- 10.1162/neco.1995.7.3.606 · DOI · Paper page
- 10.1524/zpch.1995.191.Part_2.179 · DOI
- Stone M., 1974, J Roy Stat Soc, 36, 111, 10.1111/j.2517-6161.1974.tb00994.x · DOI · Paper page
Cited by
Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy
Yadav, J., Rani, A., Singh, V., & Murari, B. M. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.01.005 · Cited by 374
Spectroscopic and Clinical Aspects of Noninvasive Glucose Measurements
Khalil, O. S. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.2.165 · Cited by 331
Near-infrared oximetry of the brain
Madsen, P. L., & Secher, N. H. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00093-8 · Cited by 315
Sensors for glucose monitoring: technical and clinical aspects
Koschinsky, T., & Heinemann, L. (2001) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.188 · Cited by 288
Near-Infrared Spectroscopy—Its Versatility in Analytical Chemistry
Ozaki, Y. (2012) · Analytical Sciences · doi:10.2116/analsci.28.545 · Cited by 283
Metadata
- Authors
- Müller, U. A., Mertes, B., Fischbacher, C., Jageman, K. U., & Danzer, K.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 1997-05
- Volume
- 20
- Issue
- 5
- Pages
- 285-290
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W2410905290
- Cited by
- 65
- References
- 3
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.