Abstract

The feasibility of using near infrared reflection spectroscopy for non-invasive blood glucose monitoring is discussed. Spectra were obtained using a diode-array spectrometer with a fiberoptic measuring head with a wavelength ranging from 800 nm to 1350 nm. Calibration was performed using partial least-squares regression and radial basis function networks. The results of different methods used to evaluate the quality of the recorded spectra in order to improve the reliability of the calibration models, are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/039139889702000509

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Research works printed but not linked: 26

  1. 10.1007/BF01228130 · DOI · Paper page
  2. 10.1056/NEJM199309303291401 · DOI · Paper page
  3. Bott U., 1993, Diabetic Med, 11, 326
  4. 10.1007/BF00404077 · DOI
  5. 10.1177/039139889101400210 · DOI
  6. Jansson P.A., 1988, Amer J Physiol, 88, E118
  7. 10.1007/BF02221686 · DOI
  8. Kayashima S., 1991, IEEE Trans (BME), 38, 752
  9. 10.1023/A:1018926215306 · DOI
  10. 10.1007/BF02446645 · DOI
  11. Duncan A., A portable noninvasive blood glucose monitor
  12. Spanner G., 1996, Fresenius J Anal Chem, 3, 306, 10.1007/s0021663540306 · doi:10.1007/s0021663540306
  13. 10.1093/clinchem/38.9.1618 · DOI · Paper page
  14. Marbach R., 1993, VDI Reihe, 8
  15. 10.1366/0003702934415354 · DOI · Paper page
  16. Martens H., 1989, Multivariate calibration.
  17. Scholz V., 1992, Behandlungs- und Schulungsprogramm für Typ-I-Diabetiker.
  18. Heinemann L., 1993, Pharmakokinetik und Pharmakodynamik verschiedener Insulinpräparationen und Insulin-Analoga.
  19. MATLAB 4.3 for Windows.
  20. Demuth H., 1994, Neural network Toolbox 2 for use with Matlab, User's Guide.
  21. 10.1021/ac00162a020 · DOI · Paper page
  22. 10.1109/72.80341 · DOI · Paper page
  23. 10.1016/0169-7439(95)80039-C · DOI
  24. 10.1162/neco.1995.7.3.606 · DOI · Paper page
  25. 10.1524/zpch.1995.191.Part_2.179 · DOI
  26. Stone M., 1974, J Roy Stat Soc, 36, 111, 10.1111/j.2517-6161.1974.tb00994.x · DOI · Paper page

Cited by

Metadata

Authors
Müller, U. A., Mertes, B., Fischbacher, C., Jageman, K. U., & Danzer, K.
Venue
The International Journal of Artificial Organs
Published
1997-05
Volume
20
Issue
5
Pages
285-290
ISSN
  • 0391-3988 (ISSN-L)
  • 1724-6040
OpenAlex
W2410905290
Cited by
65
References
3
FWCI
5.54
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.