Latitudinal Clines in the Properties of a Circadian Pacemaker
Open accessThe DOI matches its Crossref record.
Abstract
The circadian rhythm of eclosion activity and its pacemaker were analyzed in a series of latitudinal races of Drosophila auraria ranging from 34.2° to 42.9°N in Japan. The phase of the rhythm (Ψ EL) to the daily photoperiod (PP) changes as daylength is increased, and the slope of Ψ EL (PP) changes with latitude. Is is sufficiently greater in the north to cause a phase reversal of northern and southern races on long versus short photoperiods. This reversal is found in assays of the pacemaker's phase (Ψ PL) as well as that of the rhythm (Ψ EL). Assay of the pacemaker shows that its period (τ) is longer in northern than in southern races, and that the amplitude of its phase response curve (PRC) is lower in the north. The period of the rhythm in all latitudinal races is longer than 24 hr in short photoperiods (LD 1:23), but is probably less than 24 hr (as an aftereffect of photoperiod) in longer days such as LD 14:10. The observed north-south differences in the phase relation of both pacemaker and rhythm to the light cycle are explained by the latitudinal clines in pacemaker properties and a postulated aftereffect of photoperiod on τ. It is suggested that the latitudinal cline in PRC amplitude has functional significance in conserving the amplitude of the pacemaker's signal to the rest of the system it times. Computer simulation shows that without such a reduction in the perceived light intensity, pacemaker amplitude will be lowered by the increase in duration of the daily light at higher latitudes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Enhanced Fitness Conferred by Naturally Occurring Variation in the Circadian Clock
Michael, T. P., Salomé, P. A., Yu, H. J., Spencer, T. R., Sharp, E. L., McPeek, M. A., Alonso, J. M., Ecker, J. R., & McClung, C. R. (2003) · Science · doi:10.1126/science.1082971 · Cited by 457
Nelson, D. E., & Takahashi, J. S. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018660 · Cited by 316
Evidence for the adaptive significance of circadian rhythms
Yerushalmi, S., & Green, R. M. (2009) · Ecology Letters · doi:10.1111/j.1461-0248.2009.01343.x · Cited by 308
Latitudinal clines: an evolutionary view on biological rhythms,
Hut, R. A., Paolucci, S., Dor, R., Kyriacou, C. P., & Daan, S. (2013) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.2013.0433 · Cited by 241
A Molecular Basis for Natural Selection at the timeless Locus in Drosophila melanogaster
Sandrelli, F., Tauber, E., Pegoraro, M., Mazzotta, G., Cisotto, P., Landskron, J., Stanewsky, R., Piccin, A., Rosato, E., Zordan, M., et al. (2007) · Science · doi:10.1126/science.1138426 · Cited by 205
Metadata
- Authors
- Pittendrigh, C. S., & Takamura, T.
- Venue
- Journal of Biological Rhythms
- Publisher
- SAGE Publications
- Published
- 1989-06
- Volume
- 4
- Issue
- 2
- Pages
- 105-123
- ISSN
- 0748-7304 (ISSN-L)
- 1552-4531
- OpenAlex
- W2075789582
- Cited by
- 89
- References
- 0
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Latitudinal Clines in the Properties of a Circadian Pacemaker. https://app.cochat.ai/papers/10.1177/074873048900400209
- The paper
- Pittendrigh, C. S., & Takamura, T. (1989). Latitudinal Clines in the Properties of a Circadian Pacemaker. Journal of Biological Rhythms. https://doi.org/10.1177/074873048900400209
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.