A Simpler Model of the Human Circadian Pacemaker
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Numerous studies have used the classic van der Pol oscillator, which contains a cubic nonlinearity, to model the effect of light on the human circadian pacemaker. Jewett and Kronauer demonstrated that Aschoff's rule could be incorporated into van der Pol type models and used a van der Pol type oscillator with higher order nonlinearities. Kronauer, Forger, and Jewett have proposed a model for light preprocessing, Process L, representing a biochemical process that converts a light signal into an effective drive on the circadian pacemaker. In the paper presented here, the authors use the classic van der Pol oscillator with Process L and Jewett and Kronauer's model of Aschoff's rule to model the human circadian pacemaker. This simpler cubic model predicts the results of a three-pulse human phase response curve experiment and a two-pulse amplitude reduction study with as much, or more, accuracy as the models of Jewett and Kronauer and Kronauer, Forger, and Jewett, which both employ a nonlinearity of degree 7. This suggests that this simpler cubic model should be considered as a potential alternative to other models of the human circadian system currently available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stability, precision, and near-24-hour period of the human circadian pacemaker
Czeisler, C. A., Duffy, J. F., Shanahan, T. L., Brown, E. N., Mitchell, J. F., Rimmer, D. W., Ronda, J. M., Silva, E. J., Allan, J. S., Emens, J. S., et al. (1999) · Science · doi:10.1126/science.284.5423.2177 · Cited by 1,705 · cited 8×
“Jewett et al. (1994) have shown that the human circadian pacemaker acts as a limit cycle oscillator.”
BackgroundMethodResultInfluentialSelf-citationExogenous and Endogenous Components in Circadian Rhythms
Aschoff, J. (1960) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1960.025.01.004 · Cited by 1,479 · cited 3×
“First, to model Aschoff’s rule, we have added an effect of light on the circadian period, following the method outlined in Jewett and Kronauer (1998). Second, to accurately predict the circadian response to brief pulses of light, we have incorporated the dynamic stimulus model (Process L) described in Kronauer et al.…”
MethodInfluentialAveraging Methods in Nonlinear Dynamical Systems
(2007) · Applied Mathematical Sciences · doi:10.1007/978-0-387-48918-6 · Cited by 1,450
Averaging Methods in Nonlinear Dynamical Systems
Sanders, J. A., & Verhulst, F. (1985) · Applied Mathematical Sciences · doi:10.1007/978-1-4757-4575-7 · Cited by 1,366 · cited 1×
“These curves were calculated using the method of averaging (Sanders and Verhulst, 1985).”
MethodMathematical model of the human circadian system with two interacting oscillators
Kronauer, R. E., Czeisler, C. A., Pilato, S. F., Moore-Ede, M. C., & Weitzman, E. D. (1982) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1982.242.1.r3 · Cited by 298 · cited 1×
“For example, Wever (1972) and Kronauer et al. (1982) used one and two van der Pol oscillators, respectively, to model human entrainment to external time cues (zeitgebers).”
MethodSelf-citationLight-induced suppression of endogenous circadian amplitude in humans
Jewett, M. E., Kronauer, R. E., & Czeisler, C. A. (1991) · Nature · doi:10.1038/350059a0 · Cited by 253 · cited 4×
“This is about half of the additional error of Kronauer et al.’s (1999) model (0.”
BackgroundMethodInfluentialSelf-citationKronauer, R. E., Forger, D. B., & Jewett, M. E. (1999) · Journal of Biological Rhythms · doi:10.1177/074873099129001073 · Cited by 185
Self-citationRevised Limit Cycle Oscillator Model of Human Circadian Pacemaker
Jewett, M. E., Forger, D. B., & Kronauer, R. E. (1999) · Journal of Biological Rhythms · doi:10.1177/074873049901400608 · Cited by 172 · cited 9×
“22 h) and less than half of the additional error of Jewett and Kronauer’s (1998) model (0.27 h). Thus, the conventional van der Pol model presented here provides a better fit to the three-pulse PRC data than either higher order model (Jewett and Kronauer, 1998; Kronauer et al., 1999). One reason that Kronauer and Jewe…”
BackgroundMethodInfluentialSelf-citationPhase-Amplitude Resetting of the Human Circadian Pacemaker via Bright Light: A Further Analysis
Jewett, M. E., Kronauer, R. E., & Czeisler, C. A. (1994) · Journal of Biological Rhythms · doi:10.1177/074873049400900310 · Cited by 149 · cited 9×
“Using the cubic model proposed here, we have simulated the two-pulse amplitude reduction experiment (Jewett et al., 1994) against which Jewett and Kronauer (1998) tested their higher order model.”
BackgroundMethodInfluentialSelf-citationKlerman, E. B., Dijk, D. J., Kronauer, R. E., & Czeisler, C. A. (1996) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1996.270.1.r271 · Cited by 120 · cited 3×
“Although many other cubic and higher order van der Pol models have used a stiffness of 0.13 (including Kronauer, 1990; Klerman et al., 1996; Jewett and Kronauer, 1998), other reports lead us to believe that a larger stiffness is acceptable.”
BackgroundMethodInfluentialSelf-citation
Cited by
Walch, O., Huang, Y., Forger, D., & Goldstein, C. (2019) · Sleep · doi:10.1093/sleep/zsz180 · Cited by 240
“In an effort to incorporate longitudinal, personalized information about the subjects’ circadian clocks, such as their phase at the time of sleep onset, we also computed the clock proxy feature using well-validated mathematical model of the circadian clock [35].”
MethodSelf-citationA global quantification of “normal” sleep schedules using smartphone data
Walch, O. J., Cochran, A., & Forger, D. B. (2016) · Science Advances · doi:10.1126/sciadv.1501705 · Cited by 226
“The mathematical model of the circadian clock takes light as its input andprovides an estimate of the circadian contribution to sleep andwake at different points in time (11, 12).”
BackgroundSelf-citationSkeldon, A. C., Derks, G., & Dijk, D.-J. (2016) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.05.011 · Cited by 165
“[91] Forger DB, Jewett ME, Kronauer RE.”
BackgroundSkeldon, A. C., Phillips, A. J. K., & Dijk, D.-J. (2017) · Scientific Reports · doi:10.1038/srep45158 · Cited by 155
“This dependence of the intrinsic period on light intensity is controlled by the parameter k in equation (4).”
BackgroundMethodSt. Hilaire, M. A., Klerman, E. B., Khalsa, S. B. S., Wright, K. P., Czeisler, C. A., & Kronauer, R. E. (2007) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2007.04.001 · Cited by 109
“Model predictions of 1-cycle/3-cycle pulses of bright light on the pacemaker— Previous models (Forger et al., 1999; Jewett et al., 1999; Kronauer et al., 1999, 2000) have accurately predicted the results of 3-pulse PRC experiments, which report the response of the pacemaker to 3 consecutive cycles…”
ResultSelf-citationKatori, M., Shi, S., Ode, K. L., Tomita, Y., & Ueda, H. R. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2116729119 · Cited by 75
Swaminathan, K., Klerman, E. B., & Phillips, A. J. K. (2017) · Journal of Biological Rhythms · doi:10.1177/0748730417699310 · Cited by 45
“Each of these model components has previously been fit and tested against human data, both individually and in combination (Forger et al., 1999; Jewett et al., 1999; Kronauer et al., 1999; Phillips and Robinson, 2007, 2008; Phillips et al., 2010).”
MethodInfluentialTime optimal entrainment control for circadian rhythm
Julius, A. A., Yin, J., & Wen, J. T. (2019) · PLOS ONE · doi:10.1371/journal.pone.0225988 · Cited by 34
“Empirical models, such as variants of the well-known JewettForger-Kronauer (JFK) model [7, 8], are simpler and capture the essential behavior of the human core body temperature oscillation and the effect of light on the phase and amplitude of this oscillation.”
MethodThe real-world association between digital markers of circadian disruption and mental health risks
Lee, M. P., Kim, D. W., Fang, Y., Kim, R., Bohnert, A. S. B., Sen, S., & Forger, D. B. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01348-6 · Cited by 29
Self-citationWearable Data Assimilation to Estimate the Circadian Phase
Kim, D. W., Lee, M. P., & Forger, D. B. (2024) · SIAM Journal on Applied Mathematics · doi:10.1137/22m1509680 · Cited by 12
Self-citation
Metadata
- Authors
- Forger, D. B., Jewett, M. E., & Kronauer, R. E.
- Venue
- Journal of Biological Rhythms
- Publisher
- SAGE Publications
- Published
- 1999-12
- Volume
- 14
- Issue
- 6
- Pages
- 533-538
- ISSN
- 0748-7304 (ISSN-L)
- 1552-4531
- OpenAlex
- W2145348595
- Cited by
- 163
- References
- 13
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.