Best Practices for Determining Resting Energy Expenditure in Critically Ill Adults
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Indirect calorimetry (IC) is the gold standard for measuring resting energy expenditure (REE) in the critically ill patient. The use of predictive equations to develop nutrition regimens can be problematic in the critical care setting, because the effects that disease, injury, and stress have on REE are often varied and unpredictable. IC testing ensures that the specific conditions of the critically ill patient are taken into account, thereby preventing potential complications from over‐ and underfeeding. The clinical indications for and appropriate applications of IC testing are discussed. In addition, 3 case studies are presented that highlight the application of IC. The clinician can face numerous obstacles in implementing IC testing, including lack of equipment, staff shortages, and lack of knowledge regarding application and interpretation of the IC study. Recommendations for addressing these challenges are discussed. In addition, guidelines on ordering and interpreting the IC study are provided. Best practices for predictive equations in critically and acutely ill patients are also presented, since IC testing is not feasible in certain situations. Given the importance of predicting REE in the critically ill patient, it is paramount that more healthcare professionals incorporate IC testing into practice. A multidisciplinary approach is helpful in developing a well‐established clinical practice. Nutrition support clinicians can promote optimal nutrition management by being well‐informed and able to provide evidence‐based recommendations for the use of IC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New methods for calculating metabolic rate with special reference to protein metabolism
Weir, J. B. D. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004363 · Cited by 5,603
McClave, S. A., Taylor, B. E., Martindale, R. G., Warren, M. M., Johnson, D. R., Braunschweig, C., McCarthy, M. S., Davanos, E., Rice, T. W., Cresci, G. A., et al. (2016) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115621863 · Cited by 3,982
A new predictive equation for resting energy expenditure in healthy individuals
Mifflin, M., St Jeor, S., Hill, L., Scott, B., Daugherty, S., & Koh, Y. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.2.241 · Cited by 2,544
A biometric study of human basal metabolism
Harris, J. A., & Benedict, F. G. (1918) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.4.12.370 · Cited by 1,980
McClave, S. A., Martindale, R. G., Vanek, V. W., McCarthy, M., Roberts, P., Taylor, B., Ochoa, J. B., Napolitano, L., Cresci, G., the A.S.P.E.N. Board of Directors, et al. (2009) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607109335234 · Cited by 1,873
Hospital Malnutrition: Prevalence, Identification and Impact on Patients and the Healthcare System
Barker, L. A., Gout, B. S., & Crowe, T. C. (2011) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph8020514 · Cited by 985
Compher, C., Frankenfield, D., Keim, N., & Roth-Yousey, L. (2006) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2006.02.009 · Cited by 923
Singer, P., Anbar, R., Cohen, J., Shapiro, H., Shalita-Chesner, M., Lev, S., Grozovski, E., Theilla, M., Frishman, S., & Madar, Z. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2146-z · Cited by 566
Organ-tissue mass measurement allows modeling of REE and metabolically active tissue mass
Gallagher, D., Belmonte, D., Deurenberg, P., Wang, Z., Krasnow, N., Pi-Sunyer, F. X., & Heymsfield, S. B. (1998) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1998.275.2.e249 · Cited by 470
Effect of age on body composition and resting metabolic rate
Fukagawa, N. K., Bandini, L. G., & Young, J. B. (1990) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1990.259.2.e233 · Cited by 261
Analysis of Estimation Methods for Resting Metabolic Rate in Critically Ill Adults
Frankenfield, D. C., Coleman, A., Alam, S., & Cooney, R. N. (2009) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607108322399 · Cited by 248
Accurate Determination of Energy Needs in Hospitalized Patients
Boullata, J., Williams, J., Cottrell, F., Hudson, L., & Compher, C. (2007) · Journal of the American Dietetic Association · doi:10.1016/j.jada.2006.12.014 · Cited by 201
The Measurement of Energy Expenditure
Branson, R. D., & Johannigman, J. A. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019006622 · Cited by 111
Cited by
McClave, S. A., Taylor, B. E., Martindale, R. G., Warren, M. M., Johnson, D. R., Braunschweig, C., McCarthy, M. S., Davanos, E., Rice, T. W., Cresci, G. A., et al. (2016) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115621863 · Cited by 3,982
“Variables in the ICU that affect the timing and accuracy of IC measurements include the presence of air leaks or chest tubes, supplemental oxygen (eg, nasal cannula, bilevel positive airway pressure), ventilator settings (fractional inspiratory oxygen and positive end-expiratory pressure), continuous renal replacement…”
BackgroundTaylor, B. E., McClave, S. A., Martindale, R. G., Warren, M. M., Johnson, D. R., Braunschweig, C., McCarthy, M. S., Davanos, E., Rice, T. W., Cresci, G. A., et al. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001525 · Cited by 1,476
“Variables in the ICU that affect the timing and accuracy of IC measurements include the presence of air leaks or chest tubes, supplemental oxygen (eg, nasal cannula, bilevel positive airway pressure), ventilator settings (fractional inspiratory oxygen and positive end-expiratory pressure), continuous renal replacement…”
BackgroundACG Clinical Guideline: Nutrition Therapy in the Adult Hospitalized Patient
McClave, S. A., DiBaise, J. K., Mullin, G. E., & Martindale, R. G. (2016) · American Journal of Gastroenterology · doi:10.1038/ajg.2016.28 · Cited by 281
Zusman, O., Kagan, I., Bendavid, I., Theilla, M., Cohen, J., & Singer, P. (2019) · Clinical Nutrition · doi:10.1016/j.clnu.2018.04.020 · Cited by 143
Vest, A. R., DiDomenico, R. J., Lichtenstein, L., Slater, T., Ekpo, E., Damluji, A. A., Bohula, E., Alviar, C. L., on behalf of the American Heart Association Acute Cardiac Care and General Cardiology Committee of the Council on Clinical Cardiology, & Council on Cardiovascular and Stroke Nursing (2026) · Circulation · doi:10.1161/cir.0000000000001405 · Cited by 23
Metadata
- Authors
- Schlein, K. M., & Coulter, S. P.
- Venue
- Nutrition in Clinical Practice
- Publisher
- Wiley
- Published
- 2013-12-12
- Volume
- 29
- Issue
- 1
- Pages
- 44-55
- ISSN
- 0884-5336 (ISSN-L)
- 1941-2452
- OpenAlex
- W2112241931
- Cited by
- 90
- References
- 13
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.