A comparative study of bovine and porcine pericardium to highlight their potential advantages to manufacture percutaneous cardiovascular implants
The DOI matches its Crossref record.
Abstract
Rationale: Prosthetic heart valves designed to be implanted percutaneously must be loaded within delivery catheters whose diameter can be as low as 18 F (6 mm). This mandatory crimping of the devices may result in deleterious damages to the tissues used for valve manufacturing. As bovine and porcine pericardial tissue are currently given preference because of their excellent availability and traceability, a preliminary comparative study was undertaken to highlight their potential advantages. Materials and methods: Bovine and pericardium patches were compared morphologically (light microscopy, scanning electron microscopy and transmission electron microscopy). The acute thrombogenicity of both materials was measured in term of platelet uptake and observed by scanning electron microscopy, porcine intact and injured arteries being used as controls. The pericardium specimens were also subjected to uniaxial tensile tests to compare their respective mechanical characteristics. Results: Both pericardiums showed a layered architecture of collagen bundles presenting some interstitial cells. They displayed wavy crimps typical of an unloaded collagenous tissue. The collagen bundles were not bound together and the fibrils were parallel with characteristic periodicity patterns of cross striations. The mesothelial cells found in vivo on the serous surface were no longer present due to tissue processing, but the adjacent structure was far more compacted when compared to the fibrous side. The fibrinocollagenous surfaces were found to be more thrombogenic for both bovine and porcine tissues and the serous side of the porcine pericardium retained more platelets when compared to the bovine samples, making the acute thrombogenicity more important in the porcine pericardium. Conclusion: Both bovine and porcine pericardium used in cardiovascular implantology can be selected to manufacture percutaneous heart valves. The selection of one pericardium preferably to the other should deserve additional testing regarding the innocuousness of crimping when loaded in delivery catheters and the long-term durability after percutaneous deployment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A sterilization method for decellularized xenogeneic cardiovascular scaffolds
Fidalgo, C., Iop, L., Sciro, M., Harder, M., Mavrilas, D., Korossis, S., Bagno, A., Palù, G., Aguiari, P., & Gerosa, G. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.11.035 · Cited by 71
Transcatheter Heart Valves: A Biomaterials Perspective
Bui, H. T., Khair, N., Yeats, B., Gooden, S., James, S. P., & Dasi, L. P. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100115 · Cited by 36
Mammalian Pericardium‐Based Bioprosthetic Materials in Xenotransplantation and Tissue Engineering
Grebenik, E. A., Gafarova, E. R., Istranov, L. P., Istranova, E. V., Ma, X., Xu, J., Guo, W., Atala, A., & Timashev, P. S. (2020) · Biotechnology Journal · doi:10.1002/biot.201900334 · Cited by 30
Metadata
- Authors
- Gauvin, R., Marinov, G., Mehri, Y., Klein, J., Li, B., Larouche, D., Guzman, R., Zhang, Z., Germain, L., & Guidoin, R.
- Venue
- Journal of Biomaterials Applications
- Publisher
- SAGE Publications
- Published
- 2012-11-08
- Volume
- 28
- Issue
- 4
- Pages
- 552-565
- ISSN
- 0885-3282 (ISSN-L)
- 1530-8022
- OpenAlex
- W2078034298
- Cited by
- 91
- References
- 0
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparative study of bovine and porcine pericardium to highlight their potential advantages to manufacture percutaneous cardiovascular implants. https://app.cochat.ai/papers/10.1177/0885328212465482
- The paper
- Gauvin, R., Marinov, G., Mehri, Y., Klein, J., Li, B., Larouche, D., Guzman, R., Zhang, Z., Germain, L., & Guidoin, R. (2013). A comparative study of bovine and porcine pericardium to highlight their potential advantages to manufacture percutaneous cardiovascular implants. Journal of Biomaterials Applications. https://doi.org/10.1177/0885328212465482
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.