Selection of a Cutoff Value for Real-Time Polymerase Chain Reaction Results to Fit a Diagnostic Purpose: Analytical and Epidemiologic Approaches
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Diagnostic laboratories frequently select a subjective cutoff value for real-time amplification assays, above which a threshold cycle (Ct) value is deemed false. Commonly, higher Ct values are interpreted as amplification or fluorescence artifacts, or cross contaminations. Although the implementation of Ct cutoff might be reasonable, its justification and selection should be based on evidence. The current article reviewed evidence-based strategies to select Ct cutoffs grouped in analytical and epidemiologic approaches. Analytical strategies use criteria gathered during the assay development and include fluorescence threshold, reaction end-cycle, limit of detection, and artifact investigation. Variability in amplification efficacy across test runs may induce some instability in an intended Ct cutoff and requires some standardization or normalization procedures. Epidemiologic strategies use criteria based on either the probability or the cost of a false test result associated with a specified cutoff. Cutoffs, depending on the intended purpose of the test, can be selected graphically to minimize the probability of either false-positive or false-negative results by using two-graph receiver operating characteristics curves. The assay's diagnostic sensitivity and specificity may vary with the tested population, thus, the estimated two-graph receiver operating characteristics curve is population dependent and should be established for the targeted population. Although the selection of a cutoff based on misclassification cost depends on infection prevalence, the selection based on predictive values does not. To optimize the test average diagnostic performance, the Ct cutoff should be selected when diagnostic odds ratio is maximal. Epidemiologic approaches were illustrated by selecting Ct cutoffs for a real-time assay for Infectious salmon anemia virus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261
Predictive Value of a Single Diagnostic Test in Unselected Populations
Vecchio, T. J. (1966) · New England Journal of Medicine · doi:10.1056/nejm196605262742104 · Cited by 941 · cited 1×
“Alternatively, the negative predictive value (NPV) corresponds to the probability that an individual is D2 given that its specimen tested negative.(21) Predictive values depend on DSe, DSp, and the prevalence of D+ within the sample population (P), as shown in the following equations:”
BackgroundArmbruster, D. A., Tillman, M. D., & Hubbs, L. M. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.7.1233 · Cited by 483
Yerushalmy, J. (1947) · Public Health Reports (1896-1970) · doi:10.2307/4586294 · Cited by 465
Modelling the limit of detection in real-time quantitative PCR
Burns, M., & Valdivia, H. (2008) · European Food Research and Technology · doi:10.1007/s00217-007-0683-z · Cited by 181 · cited 7×
“Two approaches were suggested to estimate the ASe of qPCR.(7) The first, referred to as ‘‘experimental’’ ASe (ASeexp), determines the last investigated serial dilution where at least 95% of the samples tested positive.”
BackgroundMethodInfluential
Cited by
Test sensitivity is secondary to frequency and turnaround time for COVID-19 screening
Larremore, D. B., Wilder, B., Lester, E., Shehata, S., Burke, J. M., Hay, J. A., Tambe, M., Mina, M. J., & Parker, R. (2021) · Science Advances · doi:10.1126/sciadv.abd5393 · Cited by 1,216
Yong, F. L., Law, C. W., & Wang, C. W. (2013) · BMC Cancer · doi:10.1186/1471-2407-13-280 · Cited by 176
“A Ct value of 35 was set as the cut-off value for defining as non-de tected [45,46].”
MethodKim, E., Yang, S.-M., Lim, B., Park, S. H., Rackerby, B., & Kim, H.-Y. (2020) · BMC Microbiology · doi:10.1186/s12866-020-01781-z · Cited by 98
A Multicenter Study To Evaluate the Performance of High-Throughput Sequencing for Virus Detection
Khan, A. S., Ng, S. H. S., Vandeputte, O., Aljanahi, A., Deyati, A., Cassart, J.-P., Charlebois, R. L., & Taliaferro, L. P. (2017) · mSphere · doi:10.1128/msphere.00307-17 · Cited by 38
Metadata
- Authors
- Caraguel, C. G. B., Stryhn, H., Gagné, N., Dohoo, I. R., & Hammell, K. L.
- Venue
- Journal of Veterinary Diagnostic Investigation
- Publisher
- SAGE Publications
- Published
- 2011-01
- Volume
- 23
- Issue
- 1
- Pages
- 2-15
- ISSN
- 1040-6387 (ISSN-L)
- 1943-4936
- OpenAlex
- W2169607526
- Cited by
- 240
- References
- 5
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selection of a Cutoff Value for Real-Time Polymerase Chain Reaction Results to Fit a Diagnostic Purpose: Analytical and Epidemiologic Approaches. https://app.cochat.ai/papers/10.1177/104063871102300102
- The paper
- Caraguel, C. G. B., Stryhn, H., Gagné, N., Dohoo, I. R., & Hammell, K. L. (2011). Selection of a Cutoff Value for Real-Time Polymerase Chain Reaction Results to Fit a Diagnostic Purpose: Analytical and Epidemiologic Approaches. Journal of Veterinary Diagnostic Investigation. https://doi.org/10.1177/104063871102300102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.