Selection of a Cutoff Value for Real-Time Polymerase Chain Reaction Results to Fit a Diagnostic Purpose: Analytical and Epidemiologic Approaches
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Diagnostic laboratories frequently select a subjective cutoff value for real-time amplification assays, above which a threshold cycle (Ct) value is deemed false. Commonly, higher Ct values are interpreted as amplification or fluorescence artifacts, or cross contaminations. Although the implementation of Ct cutoff might be reasonable, its justification and selection should be based on evidence. The current article reviewed evidence-based strategies to select Ct cutoffs grouped in analytical and epidemiologic approaches. Analytical strategies use criteria gathered during the assay development and include fluorescence threshold, reaction end-cycle, limit of detection, and artifact investigation. Variability in amplification efficacy across test runs may induce some instability in an intended Ct cutoff and requires some standardization or normalization procedures. Epidemiologic strategies use criteria based on either the probability or the cost of a false test result associated with a specified cutoff. Cutoffs, depending on the intended purpose of the test, can be selected graphically to minimize the probability of either false-positive or false-negative results by using two-graph receiver operating characteristics curves. The assay's diagnostic sensitivity and specificity may vary with the tested population, thus, the estimated two-graph receiver operating characteristics curve is population dependent and should be established for the targeted population. Although the selection of a cutoff based on misclassification cost depends on infection prevalence, the selection based on predictive values does not. To optimize the test average diagnostic performance, the Ct cutoff should be selected when diagnostic odds ratio is maximal. Epidemiologic approaches were illustrated by selecting Ct cutoffs for a real-time assay for Infectious salmon anemia virus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Multivariate Statistical Analysis.
Madow, W. G., & Anderson, T. W. (1959) · The American Mathematical Monthly · doi:10.2307/2308777 · Cited by 3,878
Veterinary Epidemiologic Research
Dohoo, I. R., Martin, S. W., & Stryhn, H. (2009) · Medical Entomology and Zoology · Cited by 3,034
Self-citationInhibition and facilitation of nucleic acid amplification
Wilson, I. G. (1997) · Applied and Environmental Microbiology · doi:10.1128/aem.63.10.3741-3751.1997 · Cited by 2,266 · cited 2×
“False-positive results that yield a Ct value might be explained, for instance, by cross contamination.(23) Therefore, the profile of the DSp curve might also change dramatically because of increased contamination pressure when handling tissues from heavily infected populations.”
BackgroundThe diagnostic odds ratio: a single indicator of test performance
Glas, A. S., Lijmer, J. G., Prins, M. H., Bonsel, G. J., & Bossuyt, P. M. M. (2003) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(03)00177-x · Cited by 2,261
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318 · cited 1×
“Compared with standard PCR, this method provides substantial benefits to laboratorians, including the following: 1) reduced time of analysis, 2) increased analytical sensitivity, 3) increased reproducibility, and 4) decreased cross contamination.(13) Although the cost of equipment and reagents restricted the utilizati…”
MethodPredictive Value of a Single Diagnostic Test in Unselected Populations
Vecchio, T. J. (1966) · New England Journal of Medicine · doi:10.1056/nejm196605262742104 · Cited by 941 · cited 1×
“Alternatively, the negative predictive value (NPV) corresponds to the probability that an individual is D2 given that its specimen tested negative.(21) Predictive values depend on DSe, DSp, and the prevalence of D+ within the sample population (P), as shown in the following equations:”
BackgroundThe demon-haunted world: science as a candle in the dark
(1996) · Choice Reviews Online · doi:10.5860/choice.34-0277 · Cited by 825
BRENNER, H., & GEFELLER, O. (1997) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19970515)16:9<981::aid-sim510>3.0.co;2-n · Cited by 488 · cited 1×
“, target concentration).(6) An analytical cutoff, therefore, could be justified by selecting a Ct value that corresponds to the defined lower limit of detection of the test.”
BackgroundEpidemiologic issues in the validation of veterinary diagnostic tests
Greiner, M., & Gardner, I. A. (2000) · Preventive Veterinary Medicine · doi:10.1016/s0167-5877(00)00114-8 · Cited by 484
Cited by
Test sensitivity is secondary to frequency and turnaround time for COVID-19 screening
Larremore, D. B., Wilder, B., Lester, E., Shehata, S., Burke, J. M., Hay, J. A., Tambe, M., Mina, M. J., & Parker, R. (2021) · Science Advances · doi:10.1126/sciadv.abd5393 · Cited by 1,216
Sex Differences in Molecular Signaling at Inhibitory Synapses in the Hippocampus
Tabatadze, N., Huang, G., May, R. M., Jain, A., & Woolley, C. S. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.1067-15.2015 · Cited by 190
“Based on the standard curve generated for determination of primer efficiencies, the limit of detection for each PCR product was determined (Caraguel et al. 2011) and used to set an overall detection threshold of Ct 35.”
MethodYong, F. L., Law, C. W., & Wang, C. W. (2013) · BMC Cancer · doi:10.1186/1471-2407-13-280 · Cited by 176
“A Ct value of 35 was set as the cut-off value for defining as non-de tected [45,46].”
MethodKim, E., Yang, S.-M., Lim, B., Park, S. H., Rackerby, B., & Kim, H.-Y. (2020) · BMC Microbiology · doi:10.1186/s12866-020-01781-z · Cited by 98
A Multicenter Study To Evaluate the Performance of High-Throughput Sequencing for Virus Detection
Khan, A. S., Ng, S. H. S., Vandeputte, O., Aljanahi, A., Deyati, A., Cassart, J.-P., Charlebois, R. L., & Taliaferro, L. P. (2017) · mSphere · doi:10.1128/msphere.00307-17 · Cited by 38
“Nevertheless, qPCR assays most often have lower efficiencies (because of poor primer/probe design and reagent shortage as the reaction progresses over time) and the lowest LOD is rarely met (28, 29).”
Background
Metadata
- Authors
- Caraguel, C. G. B., Stryhn, H., Gagné, N., Dohoo, I. R., & Hammell, K. L.
- Venue
- Journal of Veterinary Diagnostic Investigation
- Publisher
- SAGE Publications
- Published
- 2011-01
- Volume
- 23
- Issue
- 1
- Pages
- 2-15
- ISSN
- 1040-6387 (ISSN-L)
- 1943-4936
- OpenAlex
- W2169607526
- Cited by
- 240
- References
- 23
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.