Pain Assessment of Subcutaneous Injections
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To compare injection pain after subcutaneous administration of four different solution volumes. DESIGN: Double-blind, randomized, prospective, multiple crossover study. SETTING: Steno Diabetes Centre, Gentofte, Denmark. PARTICIPANTS: Eighteen healthy volunteers, 9 women and 9 men, aged 21-30 years. METHODS: The subjects were injected with four different volumes (0.2, 0.5, 1.0, 1.5 mL) of NaCl 0.9%. The study was performed on 2 days with a 1-week washout period between the study days. On each study day the subjects received four injections in each thigh. To evaluate the validity of our pain assessing model the subjects received eight injections of 0.5 mL on one of the study days. Pain assessment was done immediately after each injection using both a 10-cm visual analog scale (VAS) and a six-item verbal rating scale (VRS). RESULTS: A significant difference in pain score on both the VAS (p < 0.05) and the VRS (p < 0.01) was seen between the four injection volumes. The pain was significantly increased with volumes of 1.0 and 1.5 mL. No significant difference in injection pain could be detected between 0.2 and 0.5 mL and between 1.0 and 1.5 mL. No significant period or carryover effect could be detected in the study. A significant correlation between the pain score on the VAS and the pain score on the VRS was found (r = 0.79, p < 0.0001). CONCLUSIONS: The pain of a subcutaneous injection is related to injection volume in the thigh. The results show that increasing the volume from 0.5 to 1.0 mL increases the pain significantly. The findings from this study should be considered when injection preparations for subcutaneous administration are formulated. The volume should generally be less than 1.0 mL if injected into the thigh.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Usach, I., Martinez, R., Festini, T., & Peris, J.-E. (2019) · Advances in Therapy · doi:10.1007/s12325-019-01101-6 · Cited by 358
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286
A review of Formulations of Commercially Available Antibodies
Strickley, R. G., & Lambert, W. J. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.03.017 · Cited by 271
Subcutaneous Absorption of Biotherapeutics: Knowns and Unknowns
Richter, W. F., & Jacobsen, B. (2014) · Drug Metabolism and Disposition · doi:10.1124/dmd.114.059238 · Cited by 235
Role of Buffers in Protein Formulations
Zbacnik, T. J., Holcomb, R. E., Katayama, D. S., Murphy, B. M., Payne, R. W., Coccaro, R. C., Evans, G. J., Matsuura, J. E., Henry, C. S., & Manning, M. C. (2017) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2016.11.014 · Cited by 195
Hirsch, L., Gibney, M., Berube, J., & Manocchio, J. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600216 · Cited by 96
““Which pen needle (1) was easier to insert? (2) was more comfortable? (3) did you prefer?””
BackgroundDoughty, D. V., Clawson, C. Z., Lambert, W., & Subramony, J. A. (2016) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2016.04.009 · Cited by 74
Metadata
- Authors
- Jørgensen, J. T., Rømsing, J., Rasmussen, M., Møller-Sonnergaard, J., Vang, L., & Musæus, L.
- Venue
- Annals of Pharmacotherapy
- Publisher
- SAGE Publications
- Published
- 1996-07
- Volume
- 30
- Issue
- 7-8
- Pages
- 729-732
- ISSN
- 0012-6578 (ISSN-L)
- 1060-0280
- 1542-6270
- OpenAlex
- W2163972237
- Cited by
- 81
- References
- 0
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.