Brain-Machine Interfaces: Powerful Tools for Clinical Treatment and Neuroscientific Investigations
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Brain-machine interfaces (BMIs) have exploded in popularity in the past decade. BMIs, also called brain-computer interfaces, provide a direct link between the brain and a computer, usually to control an external device. BMIs have a wide array of potential clinical applications, ranging from restoring communication to people unable to speak due to amyotrophic lateral sclerosis or a stroke, to restoring movement to people with paralysis from spinal cord injury or motor neuron disease, to restoring memory to people with cognitive impairment. Because BMIs are controlled directly by the activity of prespecified neurons or cortical areas, they also provide a powerful paradigm with which to investigate fundamental questions about brain physiology, including neuronal behavior, learning, and the role of oscillations. This article reviews the clinical and neuroscientific applications of BMIs, with a primary focus on motor BMIs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Brain–computer interface–based communication in the completely locked-in State
Chaudhary, U., Xia, B., Silvoni, S., Cohen, L. G., & Birbaumer, N. (2017) · PLOS Biology · doi:10.1371/journal.pbio.1002593 · Cited by 235
RetractedBrain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
The origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 5×
“In 1988, Farwell and Donchin showed that an event-related potential, the P300 response, could be used to communicate with a computer (Farwell and Donchin 1988).”
BackgroundInfluentialOptimal feedback control as a theory of motor coordination
Todorov, E., & Jordan, M. I. (2002) · Nature Neuroscience · doi:10.1038/nn963 · Cited by 3,081
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Error Correction, Sensory Prediction, and Adaptation in Motor Control
Shadmehr, R., Smith, M. A., & Krakauer, J. W. (2010) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-060909-153135 · Cited by 1,869
Cited by
EEG-Based BCI Control Schemes for Lower-Limb Assistive-Robots
Tariq, M., Trivailo, P. M., & Simic, M. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00312 · Cited by 245
“Recent reviews on EEG-BCI for communication and rehabilitation of lower-limbs (LL) could be found in (Cervera et al., 2018; Deng et al., 2018; He et al., 2018a; Lazarou et al., 2018; Semprini et al., 2018; Slutzky, 2018).”
BackgroundStrategies and prospects of effective neural circuits reconstruction after spinal cord injury
Yang, B., Zhang, F., Cheng, F., Ying, L., Wang, C., Shi, K., Wang, J., Xia, K., Gong, Z., Huang, X., et al. (2020) · Cell Death & Disease · doi:10.1038/s41419-020-2620-z · Cited by 128
Power-saving design opportunities for wireless intracortical brain–computer interfaces
Even-Chen, N., Muratore, D. G., Stavisky, S. D., Hochberg, L. R., Henderson, J. M., Murmann, B., & Shenoy, K. V. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0595-9 · Cited by 118
“We focus on three main questions: (1) what type of signal should be recorded from the brain, (2) how reliable this signal should be, and (3) how the resulting new specifications will affect the iBCI neural interface design, with particular emphasis on its power consumption.”
BackgroundDecoding spoken English from intracortical electrode arrays in dorsal precentral gyrus
Wilson, G. H., Stavisky, S. D., Willett, F. R., Avansino, D. T., Kelemen, J. N., Hochberg, L. R., Henderson, J. M., Druckmann, S., & Shenoy, K. V. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abbfef · Cited by 103
Mugler, E. M., Tate, M. C., Livescu, K., Templer, J. W., Goldrick, M. A., & Slutzky, M. W. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1206-18.2018 · Cited by 96
Self-citationRobust and accurate decoding of hand kinematics from entire spiking activity using deep learning
Ahmadi, N., Constandinou, T. G., & Bouganis, C.-S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abde8a · Cited by 69
Novel graphene electrode for retinal implants: an in vivo biocompatibility study
Nguyen, D., Valet, M., Dégardin, J., Boucherit, L., Illa, X., de la Cruz, J., del Corro, E., Bousquet, J., Garrido, J. A., Hébert, C., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.615256 · Cited by 36
“Keywords: graphene, prosthesis, biocompatibility, retina, implant INTRODUCTION Brain machine interfaces are emerging technologies to restore perception and action following different degenerative diseases and traumatic incidents (Slutzky, 2019).”
BackgroundSpeech-related dorsal motor cortex activity does not interfere with iBCI cursor control
Stavisky, S. D., Willett, F. R., Avansino, D. T., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5b72 · Cited by 25
Farkhondeh Tale Navi, F., Heysieattalab, S., Ramanathan, D. S., Raoufy, M. R., & Nazari, M. A. (2022) · Neuroscience · doi:10.1016/j.neuroscience.2021.12.004 · Cited by 19
Metadata
- Authors
- Slutzky, M. W.
- Venue
- The Neuroscientist
- Publisher
- SAGE Publications
- Published
- 2018-05-17
- Volume
- 25
- Issue
- 2
- Pages
- 139-154
- ISSN
- 1073-8584 (ISSN-L)
- 1089-4098
- OpenAlex
- W2803657903
- Cited by
- 81
- References
- 66
- FWCI
- 4.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.