The Development of the Nucleus® Freedom™ Cochlear Implant System
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
Cochlear Limited (Cochlear™) released the fourth-generation cochlear implant system, Nucleus® Freedom™, in 2005. Freedom is based on 25 years of experience in cochlear implant research and development and incorporates advances in medicine, implantable materials, electronic technology, and sound coding. This article presents the development of Cochlear's implant systems, with an overview of the first 3 generations, and details of the Freedom system: the CI24RE receiver-stimulator, the Contour Advance™ electrode, the modular Freedom processor, the available speech coding strategies, the input processing options of SmartSound™ to improve the signal before coding as electrical signals, and the programming software. Preliminary results from multicenter studies with the Freedom system are reported, demonstrating better levels of performance compared with the previous systems. The final section presents the most recent implant reliability data, with the early findings at 18 months showing improved reliability of the Freedom implant compared with the earlier Nucleus 3 System. Also reported are some of the findings of Cochlear's collaborative research programs to improve recipient outcomes. Included are studies showing the benefits from bilateral implants, electroacoustic stimulation using an ipsilateral and/or contralateral hearing aid, advanced speech coding, and streamlined speech processor programming.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2011) · SpringerReference · doi:10.1007/springerreference_16847 · Cited by 12,534
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Friesen, L. M., Shannon, R. V., Baskent, D., & Wang, X. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1381538 · Cited by 1,049
Rf, G. (1985) · Cited by 949
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502 · cited 2×
“For the 10-mm Hybrid electrode, the location of the cochleostomy, the technique for creating the opening, and the orientation of the electrode array during insertion have been shown to be important for hearing preservation.(98,99) A separate multicenter European study is currently investigating whether hearing can be…”
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Electrical stimulation of the auditory nerve: The effect of electrode position on neural excitation
Shepherd, R. K., Hatsushika, S., & Clark, G. M. (1993) · Hearing Research · doi:10.1016/0378-5955(93)90265-3 · Cited by 360
Speech and melody recognition in binaurally combined acoustic and electric hearing
Kong, Y.-Y., Stickney, G. S., & Zeng, F.-G. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1857526 · Cited by 351
Simultaneous Bilateral Cochlear Implantation in Adults: A Multicenter Clinical Study
Litovsky, R. Y., Parkinson, A. J., Arcaroli, J., & Sammeth, C. A. (2006) · Ear and Hearing · doi:10.1097/01.aud.0000246816.50820.42 · Cited by 350
Loizou, P. C. (1998) · IEEE Signal Processing Magazine · doi:10.1109/79.708543 · Cited by 326
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“The Nucleus Freedom system (CI24R and CI24RE) adopts this high rate mode and can attain a maximum total rate of 32 000 Hz [46].”
BackgroundMethodInfluentialWireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
Visual activation of auditory cortex reflects maladaptive plasticity in cochlear implant users
Sandmann, P., Dillier, N., Eichele, T., Meyer, M., Kegel, A., Pascual-Marqui, R. D., Marcar, V. L., Jäncke, L., & Debener, S. (2012) · Brain · doi:10.1093/brain/awr329 · Cited by 259
Neuromodulation for Brain Disorders: Challenges and Opportunities
Johnson, M. D., Lim, H. H., Netoff, T. I., Connolly, A. T., Johnson, N., Roy, A., Holt, A., Lim, K. O., Carey, J. R., Vitek, J. L., et al. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244890 · Cited by 251
“This success has pushed forward the rapid development of miniaturized processors, advanced electrode array technologies, new current-steering approaches, and semiautomated fitting and signal processing algorithms [34], [36]–[38]—all of which could”
BackgroundSelf‐Powered Implantable Medical Devices: Photovoltaic Energy Harvesting Review
Zhao, J., Ghannam, R., Htet, K. O., Liu, Y., Law, M., Roy, V. A. L., Michel, B., Imran, M. A., & Heidari, H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000779 · Cited by 218
Wireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling
Jegadeesan, R., Agarwal, K., Guo, Y.-X., Yen, S.-C., & Thakor, N. V. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2615623 · Cited by 184
“However, in many of the current day implants [3], [4], the power receivers are positioned just below the skin, which perfectly suits the NCC scheme.”
BackgroundPena, A. E., Kuntaegowdanahalli, S. S., Abbas, J. J., Patrick, J., Horch, K. W., & Jung, R. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa814d · Cited by 22
Self-citation
Metadata
- Authors
- Patrick, J. F., Busby, P. A., & Gibson, P. J.
- Venue
- Trends in Amplification
- Publisher
- SAGE Publications
- Published
- 2006-12
- Volume
- 10
- Issue
- 4
- Pages
- 175-200
- ISSN
- 1084-7138 (ISSN-L)
- OpenAlex
- W2168349646
- Cited by
- 196
- References
- 63
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.