The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Dynamic Monitoring of Cell Adhesion and Spreading on Microelectronic Sensor Arrays
Open accessAbstract
Cellular interaction with and adhesion on different biological surfaces is a dynamic and integrated process requiring the participation of specialized cell surface receptors, structural proteins, signaling proteins, and the cellular cytoskeleton. In this report, the authors describe a label-free and real-time method for measuring and monitoring cell adhesion on special microplates integrated with electronic cell sensor arrays. These plates were used in conjunction with the real-time cell electronic sensing (RT-CES) system to dynamically and quantitatively monitor the specific interaction of fibroblasts with extracellular matrix (ECM) proteins and compared with standard adhesion techniques. Cell adhesion on ECM-coated cell sensor arrays is dependent on the concentration of ECM proteins coated and is inhibited by agents that disrupt the interaction of ECM with cell surface receptors. Furthermore, the authors demonstrate that the integrity of the actin cytoskeleton is required for productive cell adhesion and spreading on ECM-coated microelectronic sensors. Confirming earlier results, it is shown that interfering with Src expression or activity, via siRNA or small molecule, results in the disruption of adhesion and spreading of Bx PC3 cells. The results indicate that the RT-CES system offers a convenient and quantitative means of assessing the kinetics of cell adhesion in a high-throughput manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hynes (2002) · doi:10.1016/s0092-8674(02)00971-6 · Cited by 8,606
Giancotti, F. G., & Ruoslahti, E. (1999) · Science · doi:10.1126/science.285.5430.1028 · Cited by 3,869
Selection of peptides binding to the alpha 5 beta 1 integrin from phage display library.
Koivunen, E., Gay, D. A., & Ruoslahti, E. (1993) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(20)80715-7 · Cited by 344 · cited 5×
“Furthermore, the CI is able to distinguish the adhesion quality on differentially coated surfaces such as PLL and FN.”
BackgroundInfluentialIntegrin signaling: it's where the action is
Damsky, C. H., & Ilić, D. (2002) · Current Opinion in Cell Biology · doi:10.1016/s0955-0674(02)00368-x · Cited by 171
Cited by
Cell death assays for drug discovery
Kepp, O., Galluzzi, L., Lipinski, M., Yuan, J., & Kroemer, G. (2011) · Nature Reviews Drug Discovery · doi:10.1038/nrd3373 · Cited by 558
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Liberio, M. S., Sadowski, M. C., Soekmadji, C., Davis, R. A., & Nelson, C. C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112122 · Cited by 85
Metadata
- Authors
- Atienza, J. M., Zhu, J., Wang, X., Xu, X., & Abassi, Y.
- Venue
- SLAS Discovery
- Publisher
- Elsevier BV
- Published
- 2005-12
- Volume
- 10
- Issue
- 8
- Pages
- 795-805
- ISSN
- 2472-5552 (ISSN-L)
- OpenAlex
- W2140657586
- Cited by
- 215
- References
- 4
- FWCI
- 2.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic Monitoring of Cell Adhesion and Spreading on Microelectronic Sensor Arrays. https://app.cochat.ai/papers/10.1177/1087057105279635
- The paper
- Atienza, J. M., Zhu, J., Wang, X., Xu, X., & Abassi, Y. (2005). Dynamic Monitoring of Cell Adhesion and Spreading on Microelectronic Sensor Arrays. SLAS Discovery. https://doi.org/10.1177/1087057105279635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.