Pain upon inserting a peripheral intravenous catheter: Size does not matter
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: Approximately 1.2 billion peripheral intravenous catheters are inserted across the world annually. It is known that intravenous cannulation may be a painful procedure, which affects cognitive abilities by increasing anxiety and discomfort. Aim: We hypothesized that inserting a smaller sized peripheral intravenous catheter has a lower level of pain sensation compared to a larger sized catheter. Methods: This observational, cross-sectional study was conducted between May and October 2016, in which surgical patients, aged 18 years or older, were eligible to participate. Experienced anesthesiologists and nurse anesthetists routinely obtained peripheral intravenous access according to the standards of care. The primary outcome was pain (verbal numeric rating scale, 0–10) upon intravenous cannulation. Results: A total of 1063 patients were included and they were divided into four groups: group 1, 22 gauge (N = 29); group 2, 20 gauge (N = 447); group 3, 18 gauge (N = 531); and group 4, sized over 18 gauge (N = 56). Inserting an 18-gauged peripheral intravenous catheter resulted in the lowest pain score (3.2 ± 2.0). As a result of the multivariate linear analysis, five factors were significantly associated with pain upon inserting a peripheral intravenous catheter (sex, American Society of Anesthesiology classification, a patients risk profile on the A-DIVA scale, site of cannulation on the extremity, and whether or not the attempt was successful); however, the size of the inserted peripheral intravenous catheter had no significant relation to the primary outcome. Conclusion: Inserting a smaller sized peripheral intravenous catheter did not result in a lower pain sensation. Moreover, to prevent pain upon inserting a peripheral intravenous catheter, an unsuccessful attempt must be avoided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Faul, F., Erdfelder, E., Lang, A.-G., & Buchner, A. (2007) · Behavior Research Methods · doi:10.3758/bf03193146 · Cited by 65,971
Hawker, G. A., Mian, S., Kendzerska, T., & French, M. (2011) · Arthritis Care & Research · doi:10.1002/acr.20543 · Cited by 4,924
How stress influences the immune response
Padgett, D. A., & Glaser, R. (2003) · Trends in Immunology · doi:10.1016/s1471-4906(03)00173-x · Cited by 1,059
Fear and anxiety: divergent effects on human pain thresholds
Rhudy, J. L., & Meagher, M. W. (2000) · Pain · doi:10.1016/s0304-3959(99)00183-9 · Cited by 913
Exacerbation of Pain by Anxiety Is Associated with Activity in a Hippocampal Network
Ploghaus, A., Narain, C., Beckmann, C. F., Clare, S., Bantick, S., Wise, R., Matthews, P. M., Rawlins, J. N. P., & Tracey, I. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-24-09896.2001 · Cited by 822
Racine, M., Tousignant-Laflamme, Y., Kloda, L. A., Dion, D., Dupuis, G., & Choinière, M. (2012) · Pain · doi:10.1016/j.pain.2011.11.025 · Cited by 691
Cited by
van Loon, F. H. J., van Hooff, L. W. E., de Boer, H. D., Koopman, S. S. H. A., Buise, M. P., Korsten, H. H. M., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2019) · Journal of Clinical Medicine · doi:10.3390/jcm8020144 · Cited by 157
“Likewise, a smaller diameter of the target vein was reported as a risk factor for failure upon the first attempt of intravenous cannulation in previous publications [7,11].”
BackgroundSelf-citationRodriguez-Calero, M. A., de Pedro-Gomez, J. E., Molero-Ballester, L. J., Fernandez-Fernandez, I., Matamalas-Massanet, C., Moreno-Mejias, L., Blanco-Mavillard, I., Moya-Suarez, A. B., Personat-Labrador, C., & Morales-Asencio, J. M. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030799 · Cited by 60
“Situations of difficult access, as well as provoking multiple punctures, often result in cannulation manoeuvres that generate more tissue damage, with possible adverse effects for the patient, thus degrading the quality of healthcare and the user’s satisfaction [3,31,32].”
BackgroundDrugeon, B., Schults, J. A., Ray‐Barruel, G., Xu, G. (., Ball, D., Yasuda, H., Drugeon, R., Mercier, J., Mihala, G., Barker, N., et al. (2026) · Journal of Advanced Nursing · doi:10.1111/jan.17007 · Cited by 3
Metadata
- Authors
- van Loon, F. H., Puijn, L. A., van Aarle, W. H., Dierick-van Daele, A. T., & Bouwman, A. R.
- Venue
- The Journal of Vascular Access
- Publisher
- SAGE Publications
- Published
- 2018-03-04
- Volume
- 19
- Issue
- 3
- Pages
- 258-265
- ISSN
- 1129-7298 (ISSN-L)
- 1724-6032
- OpenAlex
- W2792381439
- Cited by
- 45
- References
- 6
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pain upon inserting a peripheral intravenous catheter: Size does not matter. https://app.cochat.ai/papers/10.1177/1129729817747531
- The paper
- van Loon, F. H., Puijn, L. A., van Aarle, W. H., Dierick-van Daele, A. T., & Bouwman, A. R. (2018). Pain upon inserting a peripheral intravenous catheter: Size does not matter. The Journal of Vascular Access. https://doi.org/10.1177/1129729817747531
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.