Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 51 of the 53 references it cites were found in a registry or an index; 7 of the 13 sources its claims cite were checked for support.

The Modified A-DIVA Scale as a Predictive Tool for Prospective Identification of Adult Patients at Risk of a Difficult Intravenous Access: A Multicenter Validation Study

Open access
van Loon, Fredericus H. J., van Hooff, Loes W. E., de Boer, Hans D., Koopman, Seppe S. H. A., Buise, Marc P., Korsten, Hendrikus H. M., Dierick-van Daele, Angelique T. M., Bouwman, Arthur R. A. · 2019 · Journal of Clinical Medicine

Abstract

Peripheral intravenous cannulation is the most common invasive hospital procedure but is associated with a high failure rate. This study aimed to improve the A-DIVA scale (Adult Difficult Intra Venous Access Scale) by external validation, to predict the likelihood of difficult intravenous access in adults. This multicenter study was carried out throughout five hospitals in the Netherlands. Adult participants were included, regardless of their indication for intravenous access, demographics, and medical history. The main outcome variable was defined as failed peripheral intravenous cannulation on the first attempt. A total of 3587 participants was included in this study. The first attempt success rate was 81%. Finally, five variables were included in the prediction model: a history of difficult intravenous cannulation, a difficult intravenous access as expected by the practitioner, the inability to detect a dilated vein by palpating and/or visualizing the extremity, and a diameter of the selected vein less than 3 millimeters. Based on a participant’s individual score on the A-DIVA scale, they were classified into either a low, moderate, or high-risk group. A higher score on the A-DIVA scale indicates a higher risk of difficult intravenous access. The five-variable additive A-DIVA scale is a reliable and generalizable predictive scale to identify patients at risk of difficult intravenous access.

Overview

CoChat Summary

TL;DR

This multicenter cross-sectional study evaluated a modified five-variable A-DIVA scale in 3587 adults across five Dutch hospitals and found a first-attempt peripheral IV cannulation success rate of 81%. The additive scale classified patients into low, moderate, and high risk, with failed first attempts in 4%, 37%, and 94% respectively, and showed good discrimination (AUC 96–97%).

Key findings

  • Among 3587 included participants, first-attempt success was 81% (2923 participants); 4676 punctures were performed overall.
  • The final five-variable model included: history of difficult IV access (OR 2.7, 95% CI 1.6–4.4); practitioner-expected difficult IV access (OR 2.6, 95% CI 1.6–4.0); inability to detect a dilated vein by palpation (OR 4.8, 95% CI 2.5–8.1); inability to detect a dilated vein by visualization (OR 5.9, 95% CI 2.5–10.1); and target vein diameter <3 mm (OR 3.5, 95% CI 2.7–4.4).
  • Risk groups: low risk (A-DIVA score 0 or 1) included 2619 participants with 103 failed first attempts (4%); moderate risk (score 2 or 3) included 610 participants with 226 failed first attempts (37%); high risk (score 4 or 5) included 358 participants with 335 failed first attempts (94%). Relative risks were 0.07 (95% CI 0.06–0.08), 2.52 (95% CI 2.20–2.88), and 8.97 (95% CI 8.08–9.96), respectively.
  • First-attempt success by A-DIVA score was 98% for score 0, 90% for score 1, 69% for score 2, 55% for score 3, 14% for score 4, and 2% for score 5. The AUC was 96% (SE 0.002) in the development cohort and 97% (SE 0.003) in the evaluation cohort; Hosmer-Lemeshow p values were 0.086 and 0.104, and Cronbach’s α was 0.78 with an intraclass correlation coefficient of 0.78 (95% CI 0.77–0.79, p < 0.001).

Methods

  • Multicenter, multidisciplinary cross-sectional study conducted in five Dutch hospitals (Catharina, Martini, Zuyderland, Saint Anna, and Maasstad) between January 2017 and May 2018. Participants were adults over 18 years, inpatients and outpatients, included regardless of ASA physical status, demographics, and medical history; exclusions included lack of informed consent, inability to understand/answer the questionnaire, pre-existing IV access, and protocol violation.
  • A total of 3689 participants were recruited; 102 were excluded, leaving 3587 analyzed. The sample was randomly divided into a development cohort of 1255 participants and an evaluation/validation cohort of 2332 participants. The primary outcome was failed peripheral intravenous cannulation on the first attempt; success was defined as ability to inject a saline flush without signs of infiltration.
  • Twenty-eight predictors were measured. Univariate logistic regression was followed by multivariate logistic regression with backward elimination; the additive A-DIVA score was constructed from β coefficients. Performance was assessed with ROC AUC, Hosmer-Lemeshow calibration, Cronbach’s alpha, intraclass correlation coefficient, and unit-wise comparisons; reporting followed TRIPOD and STROBE statements.

Limitations

  • The authors state the study population consisted largely of surgical patients recruited from a preoperative setting, with relatively smaller cohorts from the labor ward and emergency department, potentially differing from acute care or healthier labor ward populations.
  • The authors state some included factors were qualitative or subjective—such as skin shade or whether a vein could be detected by palpation/visualization—and inter-observer variability may have affected measurements.
  • The authors state the observational cross-sectional design creates a risk of selection bias and possible confounding, although recall/information bias was thought minimal due to the prospective design. Evident from the Methods: the validation cohort was a random split of the same study sample rather than an independent external dataset, despite the paper’s external validation framing.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.3390/jcm8020144

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 First attempt success rates by the depending A-DIVA (Adult Difficult Intra Venous Access) score. Solid line (red) = first attempt success rate. Dashed line (brown) = 95% confidence interval, divided into a lower and upper bound. Striped line (blue) = linear trend line of the first attempt success rates.
Figure 1 First attempt success rates by the depending A-DIVA (Adult Difficult Intra Venous Access) score. Solid line (red) = first attempt success rate. Dashed line (brown) = 95% confidence interval, divided into a lower and upper bound. Striped line (blue) = linear trend line of the first attempt success rates.CC BY · PubMed Central

Verification

Claims the paper makes

7 Valid · 0 Not valid · 3 Not checked · 41 Own results and interpretations

21 more claims

Create a free account to see all 51 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 17
  • It may state two separate claims as one. 14

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

4 of 4

Citations

Cites

Show all 53 references

Cited by

See all 157

Metadata

Authors
van Loon, F. H. J., van Hooff, L. W. E., de Boer, H. D., Koopman, S. S. H. A., Buise, M. P., Korsten, H. H. M., Dierick-van Daele, A. T. M., & Bouwman, A. R. A.
Affiliations
  • Department of Technical and Anesthesia Nursing Sciences, Fontys University of Applied Sciences, 5631 Eindhoven, The Netherlands
  • Emergency Department, Catharina Hospital, 5623 Eindhoven, The Netherlands
  • Department of Anesthesiology, Pain Medicine and Procedural Sedation and Analgesia, Martini General Hospital, 9728 Groningen, The Netherlands
  • Maasstad Ziekenhuis (NL)
  • Catharina Ziekenhuis (NL)
  • Department of People and Health Sciences, Fontys University of Applied Sciences, 5631 Eindhoven, The Netherlands
  • Department of Anesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, 5623 Eindhoven, The Netherlands
Venue
Journal of Clinical Medicine
Publisher
MDPI AG
Published
2019-01-26
Volume
8
Issue
2
Pages
144
ISSN
2077-0383 (ISSN-L)
OpenAlex
W2913599917
Cited by
157
References
53
Citations by year
2026: 31 · 2025: 23 · 2024: 31 · 2023: 25 · 2022: 25 · 2021: 12 · 2020: 6 · 2019: 1
FWCI
16.15
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Medicine (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • TU/e Research Portal (publishedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • TU/e Research Portal (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
Keywords
difficult venous access, peripheral venous cannulation, cannulation failure, risk prediction, vein diameter

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-09-30, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-09-30 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Modified A-DIVA Scale as a Predictive Tool for Prospective Identification of Adult Patients at Risk of a Difficult Intravenous Access: A Multicenter Validation Study. https://app.cochat.ai/papers/10.3390/jcm8020144
The paper
van Loon, F. H. J., van Hooff, L. W. E., de Boer, H. D., Koopman, S. S. H. A., Buise, M. P., Korsten, H. H. M., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2019). The Modified A-DIVA Scale as a Predictive Tool for Prospective Identification of Adult Patients at Risk of a Difficult Intravenous Access: A Multicenter Validation Study. Journal of Clinical Medicine. https://doi.org/10.3390/jcm8020144

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.