Evaluation of FreeStyle Libre Flash Glucose Monitoring System on Glycemic Control, Health-Related Quality of Life, and Fear of Hypoglycemia in Patients with Type 1 Diabetes
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Background/objectives: In the current era of modern technology and the development of smart devices such as the flash glucose monitoring (FGM) systems, patients can easily monitor their glucose levels more frequently without any inconvenience. In this study, we evaluate the effect of FreeStyle Libre FGM system on glycemic control, hypoglycemia, health-related quality of life (QoL), and the fear of hypoglycemia (FOH) among children and young people with type 1 diabetes (T1D). Design and methods: A prospective study was conducted at the Diabetes Treatment Center, Prince Sultan Military Medical City, Riyadh, Saudi Arabia, between January 2017 and May 2017 on 47 (aged 13-19 years) registered patients with T1D who used conventional finger-pricking method for self-testing the glucose. At baseline visit, the FGM sensors were placed on each participant by a trained diabetes educator. The data collected from the sensors were computed to generate the respective ambulatory glucose profiles so as to determine the total number of scans conducted during the study period. At the baseline and at 3 months of the experiment, a trained interviewer administered the questionnaire Hypoglycemia Fear Survey-Child Version (HFS-C) and PedsQL 3.0 (QoL questionnaire) to each patient. The age, sex, weight, height, adjusted body mass index, duration of diabetes, treatment modality, and glycosylated hemoglobin A 1c (HbA 1c) levels of each patient were recorded. Results: As compared with the baseline, a significant improvement was noted in the behavior of FOH ( P = .0001), worry ( P = .0001), QoL ( P = .002), HbA 1c level ( P = .008), and hypoglycemia ( P = .023) at 3 months. Significant improvement was noted in the behavior ( P = .0001), worry ( P = .0001), QoL ( P = .003), HbA 1c level ( P = .014), and hypoglycemia ( P = .001) among the multiple-dose insulin injection–treated patients as compared with baseline. Significant improvement was noted in the behavior ( P = .0001), worry ( P = .0001), and hypoglycemia ( P = .001) among the insulin pump–treated patients as compared with baseline. A positive correlation was recorded in the behavior ( r = .47; P < .001), QoL ( r = .70; P < .001), and the mean number of FGM scans. A negative correlation was recorded in the worry ( r = −.43; P = .002), HbA 1c level ( r = −.58; P < .001), hypoglycemia ( r = −.65; P < .001), and the mean number of FGM scans. Conclusions: The frequent use of FGM scanning reduced the frequency of hypoglycemia, HbA 1c level, and worry and increased the behavior and QoL. As compared with self-testing by the conventional finger-pricking method, the use of FGM increased the frequency of self-testing and thus diabetes control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of medical care in diabetes—2013
American Diabetes Association (2013) · Diabetes Care · doi:10.2337/dc13-s011 · Cited by 4,369
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623
Herman, A., Aerts, O., Baeck, M., Bruze, M., De Block, C., Goossens, A., Hamnerius, N., Huygens, S., Maiter, D., Tennstedt, D., et al. (2017) · Contact Dermatitis · doi:10.1111/cod.12866 · Cited by 192
Self-monitoring of blood glucose by adults with diabetes in the United States population
Harris, M. I., Cowie, C. C., & Howie, L. J. (1993) · Diabetes Care · doi:10.2337/diacare.16.8.1116 · Cited by 158
Technology and diabetes self-management: an integrative review
Hunt, C. W. (2015) · World Journal of Diabetes · doi:10.4239/wjd.v6.i2.225 · Cited by 133
Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes
Slattery, D., & Choudhary, P. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0051 · Cited by 87
Cited by
Evans, M., Welsh, Z., Ells, S., & Seibold, A. (2020) · Diabetes Therapy · doi:10.1007/s13300-019-00720-0 · Cited by 185
Castellana, M., Parisi, C., Di Molfetta, S., Di Gioia, L., Natalicchio, A., Perrini, S., Cignarelli, A., Laviola, L., & Giorgino, F. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001092 · Cited by 84
Pintus, D., & Ng, S. M. (2019) · Diabetes & Metabolic Syndrome: Clinical Research & Reviews · doi:10.1016/j.dsx.2019.07.054 · Cited by 60
Landau, Z., Abiri, S., Gruber, N., Levy-Shraga, Y., Brener, A., Lebenthal, Y., Barash, G., Pinhas-Hamiel, O., & Rachmiel, M. (2018) · Acta Diabetologica · doi:10.1007/s00592-018-1218-8 · Cited by 48
Evaluation of flash glucose monitoring after long-term use: a pediatric survey
Vergier, J., Samper, M., Dalla-Vale, F., Ventura, V., Baucher, F., Joubert, F., Pons, C., De Oliveira, M., Salet, R., Faure-Galon, N., et al. (2019) · Primary Care Diabetes · doi:10.1016/j.pcd.2018.08.004 · Cited by 32
Metadata
- Authors
- Al Hayek, A. A., Robert, A. A., & Al Dawish, M. A.
- Venue
- Clinical Medicine Insights: Endocrinology and Diabetes
- Publisher
- SAGE Publications
- Published
- 2017-01-01
- Volume
- 10
- Pages
- 117955141774695
- ISSN
- 1178-1173 (ISSN-L)
- 1179-5514
- OpenAlex
- W2771328069
- Cited by
- 103
- References
- 8
- FWCI
- 6.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of FreeStyle Libre Flash Glucose Monitoring System on Glycemic Control, Health-Related Quality of Life, and Fear of Hypoglycemia in Patients with Type 1 Diabetes. https://app.cochat.ai/papers/10.1177/1179551417746957
- The paper
- Al Hayek, A. A., Robert, A. A., & Al Dawish, M. A. (2017). Evaluation of FreeStyle Libre Flash Glucose Monitoring System on Glycemic Control, Health-Related Quality of Life, and Fear of Hypoglycemia in Patients with Type 1 Diabetes. Clinical Medicine Insights: Endocrinology and Diabetes. https://doi.org/10.1177/1179551417746957
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.