Differences of FreeStyle Libre Flash Glucose Monitoring System and Finger Pricks on Clinical Characteristics and Glucose Monitoring Satisfactions in Type 1 Diabetes Using Insulin Pump
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background: To evaluate the different experience of freestyle libre and finger pricks on clinical characteristics and glucose monitoring satisfaction (GMS) in patients with type 1 diabetes (T1D) using insulin pump (IP). Methods: A prospective study was carried out on 47 (aged 17-21 years) T1D, who used conventional finger-pricking method for self-testing the glucose. The experiments were conducted between March 2018 and September 2018. For carrying out the study, the flash glucose monitoring (FGM) sensors were placed on each participant, at the baseline visit, by a trained diabetes educator. Furthermore, to determine the total number of scans conducted during the study period, the respective ambulatory glucose profiles were generated by computing the data collected from the sensors. In addition, a trained interviewer handed over the GMS questionnaire to each patient, at the baseline and at 12 weeks of the study. Results: In comparison to the baseline (finger pricks), various parameters such as: HbA1c ( P = .042), hypoglycemia ( P = .001), mean capillary glucose ( P = .004), total daily insulin dose ( P = .0001), percentage of bolus insulin ( P = .0001), daily bolus frequency ( P = .0001), and daily carbohydrates intake ( P = .0001) showed a significant improvement at 12 weeks. Similarly, substantial augmentation was noticed, in the sub domains of GMS, that is, openness ( P = .0001), emotional burden ( P = .0001), behavioral burden ( P = .0001), and trust ( P = .0001) at 12 weeks as compared to baseline. Overall, total GMS score at baseline was 1.72 ± 0.37, which increased up to 3.41 ± 0.49 ( P = .0001) in the time period of 12 weeks. The HbA1c (r 2 = 0.45), hypoglycemia (r 2 = 0.58), and the mean number of FGM scans, exhibited a negative correlation, while GMS (r 2 = 0.52) and the mean number of FGM scans, exhibited a positive correlation. Conclusion: The frequency of hypoglycemia, HbA1c level, capillary glucose, daily carbohydrates intake decreased, while the total daily insulin dose, daily bolus insulin and total GMS score increased with the use of FGM scanning for 12 weeks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Ziegler, R., Heidtmann, B., Hilgard, D., Hofer, S., Rosenbauer, J., Holl, R., & DPV-Wiss-Initiative, F. T. (2011) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2010.00650.x · Cited by 334
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Reddy, M., Jugnee, N., El Laboudi, A., Spanudakis, E., Anantharaja, S., & Oliver, N. (2018) · Diabetic Medicine · doi:10.1111/dme.13561 · Cited by 245
Schütt, M., Kern, Krause, U., Busch, Dapp, A., Grziwotz, Mayer, I., Rosenbauer, Wagner, C., Zimmermann, et al. (2006) · Experimental and Clinical Endocrinology & Diabetes · doi:10.1055/s-2006-924152 · Cited by 218
Landau, Z., Abiri, S., Gruber, N., Levy-Shraga, Y., Brener, A., Lebenthal, Y., Barash, G., Pinhas-Hamiel, O., & Rachmiel, M. (2018) · Acta Diabetologica · doi:10.1007/s00592-018-1218-8 · Cited by 48
Anjana, R. M., Kesavadev, J., Neeta, D., Tiwaskar, M., Pradeepa, R., Jebarani, S., Thangamani, S., Sastry, N. G., Brijendra Kumar, S., Ramu, M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0063 · Cited by 42
Evaluation of flash glucose monitoring after long-term use: a pediatric survey
Vergier, J., Samper, M., Dalla-Vale, F., Ventura, V., Baucher, F., Joubert, F., Pons, C., De Oliveira, M., Salet, R., Faure-Galon, N., et al. (2019) · Primary Care Diabetes · doi:10.1016/j.pcd.2018.08.004 · Cited by 32
Cited by
Wada, E., Onoue, T., Kobayashi, T., Handa, T., Hayase, A., Ito, M., Furukawa, M., Okuji, T., Okada, N., Iwama, S., et al. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001115 · Cited by 157
Castellana, M., Parisi, C., Di Molfetta, S., Di Gioia, L., Natalicchio, A., Perrini, S., Cignarelli, A., Laviola, L., & Giorgino, F. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001092 · Cited by 84
“2 However, in some studies it was described as any glucose level ≤ 70 mg/dL 14 15 , while in other studies it was represented by any FGM-derived glycemic measures 70 mg/dL, confirmed by a second reading in the following 15 min.”
Hayase, A., Onoue, T., Kobayashi, T., Wada, E., Handa, T., Kinoshita, T., Yamagami, A., Yasuda, Y., Iwama, S., Kawaguchi, Y., et al. (2023) · Primary Care Diabetes · doi:10.1016/j.pcd.2023.09.009 · Cited by 5
Metadata
- Authors
- Al Hayek, A. A., Robert, A. A., & Al Dawish, M. A.
- Venue
- Clinical Medicine Insights: Endocrinology and Diabetes
- Publisher
- SAGE Publications
- Published
- 2019-01
- Volume
- 12
- Pages
- 1179551419861102-1179551419861102
- ISSN
- 1178-1173 (ISSN-L)
- 1179-5514
- OpenAlex
- W2955627271
- Cited by
- 44
- References
- 9
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.