Experimental study on a bedside personalized ventilation system for improving sleep comfort and quality
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A bedside personalized ventilation (PV) system was investigated by experiments on human subjects including children, adults and elderly. Short-term exposure experiment was first carried out to find out the subjects’ perception of air movement and temperature and the effect on falling asleep. Through the comparative analysis of subjective questionnaires returned from participants and objective physiological tests in all-night sleep experiments, the influence of this system on sleep comfort and quality was obtained as well as the optimal system operation parameters. For conditions with bedside PV system, the returned questionnaires from participants reflected the thermal comfort level and subjective sleep quality were relatively higher than condition without the PV system. Physiological tests results like heart rate and heart rate variability also indicated that a calmer and more comfortable sleep could be obtained with this system. Bedside, PV system could provide a more obvious positive impact on children than adults in sleep quality, and the impact on elderly subjects was not significant. Optimal conditions for improving sleep comfort and quality are to keep the room ambient temperature at 22℃, PV outlet air temperature at 21℃ and air velocity of breathing zone at 0.1 m/s. Through this study, potential applications of bedside PV system could benefit human sleep comfort and quality, particularly in summer which could also be of benefit to hospital care of patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impact of sleep debt on metabolic and endocrine function
Spiegel, K., Leproult, R., & Van Cauter, E. (1999) · The Lancet · doi:10.1016/s0140-6736(99)01376-8 · Cited by 3,668
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731 · cited 1×
“Fresh air supply and a comfortable environmental temperature are important factors to sleeping people, especially for people with sleeping disorder and apnea.(27) The fresh air requirement would be reduced by the PV system, as the personal exposure efficiency of PV system would be relatively higher than normal aircond…”
BackgroundEffect of sleep loss on C-reactive protein, an inflammatory marker of cardiovascular risk
Meier-Ewert, H. K., Ridker, P. M., Rifai, N., Regan, M. M., Price, N. J., Dinges, D. F., & Mullington, J. M. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.07.050 · Cited by 1,195
A Prospective Study of Sleep Duration and Coronary Heart Disease in Women
Ayas, N. T., White, D. P., Manson, J. E., Stampfer, M. J., Speizer, F. E., Malhotra, A., & Hu, F. B. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.2.205 · Cited by 1,155
An overview of sleepiness and accidents
DINGES, D. F. (1995) · Journal of Sleep Research · doi:10.1111/j.1365-2869.1995.tb00220.x · Cited by 891 · cited 1×
“Moreover, the lack of sufficient sleep could also be an important factor in industrial and traffic accidents and a major cause of social and public health problems.(4,5) Therefore, improvement on sleep quality is paramount to people’s life quality as well as public health and safety.”
BackgroundSkin temperature and sleep-onset latency: Changes with age and insomnia
Raymann, R. J. E. M., Swaab, D. F., & Van Someren, E. J. W. (2007) · Physiology & Behavior · doi:10.1016/j.physbeh.2006.09.008 · Cited by 152
Cited by
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Ten questions concerning well-being in the built environment
Altomonte, S., Allen, J., Bluyssen, P. M., Brager, G., Heschong, L., Loder, A., Schiavon, S., Veitch, J. A., Wang, L., & Wargocki, P. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106949 · Cited by 303
Wargocki, P., & Wyon, D. P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.020 · Cited by 290
Thermal environment and sleep quality: A review
Lan, L., Tsuzuki, K., Liu, Y. F., & Lian, Z. W. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.05.043 · Cited by 285
Self-citationExperimental study on thermal comfort of sleeping people at different air temperatures
Lan, L., Pan, L., Lian, Z., Huang, H., & Lin, Y. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.024 · Cited by 235
“We proposed a bedside personalized ventilation (PV) system and found it could be used as a potential ventilation strategy to improve indoor air quality and thermal comfort in bedroom [20,21].”
MethodSelf-citation
Metadata
- Authors
- Zhou, X., Lian, Z., & Lan, L.
- Venue
- Indoor and Built Environment
- Publisher
- SAGE Publications
- Published
- 2013-10-11
- Volume
- 23
- Issue
- 2
- Pages
- 313-323
- ISSN
- 1420-326X (ISSN-L)
- 1423-0070
- OpenAlex
- W2082365808
- Cited by
- 68
- References
- 6
- FWCI
- 8.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.