The appropriateness of clinical decision support systems alerts in supporting clinical workflows: A systematic review
Open accessThe DOI matches its Crossref record; 103 of the 103 references it cites were found in a registry or an index.
Abstract
A CDSS generates a high number of inappropriate alerts that interrupt the clinical workflow. As a result, clinicians silence, disable, or ignore alerts, thereby undermining patient safety. Therefore, the effectiveness and appropriateness of CDSS alerts need to be evaluated. A systematic review was carried out to identify the factors that affect CDSS alert appropriateness in supporting clinical workflow. Seven electronic databases (PubMed, Scopus, ACM, Science Direct, IEEE, Ovid Medline, and Ebscohost) were searched for English language articles published between 1997 and 2018. Seventy six papers met the inclusion criteria, of which 26, 24, 15, and 11 papers are retrospective cohort, qualitative, quantitative, and mixed-method studies, respectively. The review highlights various factors influencing the appropriateness and efficiencies of CDSS alerts. These factors are categorized into technology, human, organization, and process aspects using a combination of approaches, including socio-technical framework, five rights of CDSS, and Lean. Most CDSS alerts were not properly designed based on human factor methods and principles, explaining high alert overrides in clinical practices. The identified factors and recommendations from the review may offer valuable insights into how CDSS alerts can be designed appropriately to support clinical workflow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“High override rates often translate into increased clinician workload and cognitive fatigue, introducing variability and risk of human error [24].”
From Enhancing Clinician Trust in AI Diagnostics: A Dynamic Framework for Confidence Calibration and Transparency (2025) · cites this paper as [24]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Implementing a CDS tool can result in important downstream effects, both intended and unintended.”
From Electronic health record activity changes around new decision support implementation: monitoring using audit logs and topic modeling (2025) · cites this paper as [11]
In the citing paper
“for example, Guo et al. reported similar findings, demonstrating the critical importance of robust confidence calibration in reducing unnecessary clinician interventions and improving clinical workflow efficiency [24,25].”
From Enhancing Clinician Trust in AI Diagnostics: A Dynamic Framework for Confidence Calibration and Transparency (2025) · cites this paper as [24]
In the citing paper
“Prior studies found that providers often perceived or experienced increased workload such as extended duration of patient consultation, interrupted workflow, and alert overload associated with using CDS tools.10,11”
From Electronic health record activity changes around new decision support implementation: monitoring using audit logs and topic modeling (2025) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cochrane Handbook for Systematic Reviews of Interventions
(2019) · doi:10.1002/9781119536604 · Cited by 14,828
(2004) · Cited by 5,198
A model for types and levels of human interaction with automation
Parasuraman, R., Sheridan, T. B., & Wickens, C. D. (2000) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.844354 · Cited by 4,195
Fundamentals of Business Process Management
Dumas, M., La Rosa, M., Mendling, J., & Reijers, H. A. (2018) · Springer eBooks · doi:10.1007/978-3-662-56509-4 · Cited by 1,822
Work system design for patient safety: the SEIPS model
Carayon, P., Schoofs Hundt, A., Karsh, B.-T., Gurses, A. P., Alvarado, C. J., Smith, M., & Flatley Brennan, P. (2006) · Quality in Health Care · doi:10.1136/qshc.2005.015842 · Cited by 1,795
Eliminating Waste in US Health Care
Hackbarth, A. D. (2012) · JAMA · doi:10.1001/jama.2012.362 · Cited by 1,746 · cited 1×
“31,32 This review used the waste model to analyze workflow inefficiencies related to alerts.”
MethodHolden, R. J., Carayon, P., Gurses, A. P., Hoonakker, P., Hundt, A. S., Ozok, A. A., & Rivera-Rodriguez, A. J. (2013) · Ergonomics · doi:10.1080/00140139.2013.838643 · Cited by 1,221
Medication-related clinical decision support in computerized provider order entry systems: a review
Kuperman, G. J., Bobb, A., Payne, T. H., Avery, A. J., Gandhi, T. K., Burns, G., Classen, D. C., & Bates, D. W. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2170 · Cited by 763 · cited 1×
“33,108 Additional research is needed to ascertain how to best record this information and present clinicians with useful drug alerts.”
BackgroundYusof, M. M., Kuljis, J., Papazafeiropoulou, A., & Stergioulas, L. K. (2008) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2007.08.011 · Cited by 740 · cited 1×
“19,46 A survey conducted by Kucher et al. 92 showed that the use of non-interruptive alerts increases clinician’s compliance with care measures by preventing venous thromboembolism (VTE) prophylaxis among hospitalized patients.”
BackgroundSelf-citationwith the HITEC Investigators, Ancker, J. S., Edwards, A., Nosal, S., Hauser, D., Mauer, E., & Kaushal, R. (2017) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-017-0430-8 · Cited by 709 · cited 2×
“81,82 Providing clinicians with protected time to respond to alerts reduces alert-related workload and improves patient safety.”
Background
Research works printed but not linked: 16
- IOM. Health IT and patient safety. 2012National Academies PressWashington, DC
- McCoy AB, 2014, Ochsner J, 14, 195
- Enhancing CDSS alert appropriateness in clinical workflow using the lean method. O Olufisayo, Mohd Yusof, M , Ezat Wan Puteh, S , Stud Health Technol Inform. 2552018
- Improving medication use and outcomes with clinical decision support: a step by step guide. J Osheroff, 2009Published online
- Impact of electronic health record systems on information integrity: quality and safety implications. S Bowman, Perspect Heal Inf Manag. 1012013
- Eliminating waste in healthcare strategies to improve outcomes and reduce costs. E Martin, ASQ Healthc Updat. 172014
- Critical Appraisal Skills Programme. CASP critical appraisal skills programme. CASP Qual Checkl. 12018. 2018
- GPs' views on computerized drug interaction alerts: questionnaire survey. D Magnus, S Rodgers, Avery A , J Clin Pharm. 2752002
- Clinician's assessments of outpatient electronic medical record alert and reminder usability and usefulness requirements. M A Krall, D F Sittig, Proc AMIA Symp. 2002
- How to design computerized alerts to ensure safe prescribing practices. A Feldstein, S R Simon, J Schneider, Jt Comm J Qual Saf. 30112004
- A human factors investigation of medication alerts: barriers to prescriber decision-making and clinical workflow. A L Russ, A J Zillich, M S Mcmanus, AMIA. Annu Symp Proc AMIA Symp. 2009. 2009
- Some unintended consequences of clinical decision support systems. J Ash, D Sittig, E Campbell, AMIA Annu Symp Proc. 2007. 2007
- Improving patient safety by modifying provider ordering behavior using alerts (CDSS) in CPOE system. K Saxena, B R Lung, J R Becker, AMIA Annu Symp Proc. 20112011
- Alert override reasons: a failure to communicate. A E Chused, G J Kuperman, P D Stetson, AMIA Annu Symp Proc. 2008. 2008
- Trinkley KE, 2019, BMJ Heal Care Inform, 26
- Medication-related clinical decision support in computerized provider order entry systems: a review. G J Kuperman, A Bobb, T H Payne, J Am Med Informatics Assoc. 1412007 · DOI · Paper page
Cited by
Clinical Decision Support Tools in the Electronic Medical Record
Alexiuk, M. R., Elgubtan, H., & Tangri, N. (2023) · Kidney International Reports · doi:10.1016/j.ekir.2023.10.019 · Cited by 103
“10,14,15,17 In some circumstances, the magnitude of the alerts results in clinicians potentially being incapable of addressing the alerts in a timely manner.”
BackgroundChen, W., O’Bryan, C. M., Gorham, G., Howard, K., Balasubramanya, B., Coffey, P., Abeyaratne, A., & Cass, A. (2022) · Implementation Science Communications · doi:10.1186/s43058-022-00326-x · Cited by 74
“examined barriers and enablers to using CDS systems— one investigating CDS targeting medication use [24] and one focussing on alert-based CDS systems [26].”
BackgroundGiddings, R., Joseph, A., Callender, T., Janes, S. M., van der Schaar, M., Sheringham, J., & Navani, N. (2024) · The Lancet Digital Health · doi:10.1016/s2589-7500(23)00241-8 · Cited by 82
“With analogous potential to add value, 11 there were similar concerns regarding factors such as alert fatigue, 8,76 data quality, 9 and unintended consequences 11 along with model design requirements 8,11,76 and retention of clinician autonomy.”
BackgroundOng, J. C. L., Jin, L., Elangovan, K., Lim, G. Y. S., Lim, D. Y. Z., Sng, G. G. R., Ke, Y. H., Tung, J. Y. M., Zhong, R. J., Koh, C. M. Y., et al. (2025) · Cell Reports Medicine · doi:10.1016/j.xcrm.2025.102323 · Cited by 58
“10–12 Greater personalization of alerts, more intuitive interfaces, and lesser emphasis on disruptive alerts show promise in improving current state of CDSS.”
Artificial intelligence tool development: what clinicians need to know?
Chew, B.-H., & Ngiam, K. Y. (2025) · BMC Medicine · doi:10.1186/s12916-025-04076-0 · Cited by 41
“Persistent concerns about integrating AI systems into existing clinical consultations include alert fatigue [26, 27], data quality, data security, transparency and accountability, alignment with standards and guidelines and unintended consequences along with model design requirements, and retention…”
Metadata
- Authors
- Olakotan, O. O., & Mohd Yusof, M.
- Affiliations
- National University of Malaysia (MY)
- Universiti Kebangsaan Malaysia (UKM), Malaysia
- Venue
- Health Informatics Journal
- Publisher
- SAGE Publications
- Published
- 2021-04
- Volume
- 27
- Issue
- 2
- Pages
- 14604582211007536-14604582211007536
- ISSN
- 1355-4743 (ISSN-L)
- 1460-4582
- 1741-2811
- OpenAlex
- W3153868122
- Cited by
- 101
- References
- 103
- Citations by year
- 2026: 35 · 2025: 27 · 2024: 11 · 2023: 11 · 2022: 15 · 2021: 2
- FWCI
- 1.73
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Health Informatics Journal (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- ministry of higher education, malaysia (FRGS/1/2018/ICT04/UKM/02/5)
- Universiti Kebangsaan Malaysia (DIP-2016-033)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- clinical decision support systems, clinical alerts, clinical workflow, alert override, patient safety, socio-technical framework, lean manufacturing, human factors, alert design
- MeSH terms
- Humans, Retrospective Studies, Databases, Factual, Decision Support Systems, Clinical, Workflow, Patient Safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.