Cited by 28Endometriosis Research and TreatmentAdvanced Proteomics Techniques and ApplicationsMass Spectrometry Techniques and Applications

New Serum Biomarkers for Detection of Endometriosis Using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Open access
Zheng, N, Pan, C, Liu, W·2011·Journal of International Medical Research

Abstract

This study used proteomic fingerprint technology, combining nano-sized magnetic beads with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI—TOF—MS), to screen for potential protein biomarkers for the diagnosis of endometriosis. Serum proteins from 126 patients with endometriosis and 120 healthy controls were profiled and compared. Biomarker pattern software identified 46 discriminating mass-to-charge m/z ratio peaks that were related to endometriosis. The model constructed by the software, based on three of these peaks ( m/z 5988.7, 7185.3 and 8929.8), generated excellent separation between the endometriosis and control groups. The sensitivity was 91.4% and the specificity 95.0%. Blind testing on a second series of serum samples from patients with endometriosis and healthy controls indicated a sensitivity of 89.3% and a specificity of 90.0%. Biomarkers for endometriosis can be discovered in serum by MALDI—TOF—MS in combination with nano-sized magnetic beads. The pattern of combined markers provides a powerful and reliable diagnostic method for endometriosis, with high sensitivity and specificity.

Integrity signals

Registry

Crossref · 10.1177/147323001103900406

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A proteomic fingerprint model based on three peptide peaks had 91.4% sensitivity and 95% specificity to detect endometriosis when comparing 126 patients with endometriosis with 120 healthy controls.

    “A proteomic fingerprint model, based on three peptide peaks, had 91.4% sensitivity and 95% specificity to detect endometriosis when comparing 126 patients with endometriosis with 120 healthy controls [90].”

    From Update on biomarkers for the detection of endometriosis (2015) · cites this paper as [90]

  • This combination of peptide peaks was validated in an independent cohort, showing sensitivity of 89.3% and specificity of 90%.

    “Furthermore, this combination of peptide peaks was validated in an independent cohort, showing a sensitivity of 89.3% and a specificity of 90% [90].”

    From Update on biomarkers for the detection of endometriosis (2015) · cites this paper as [90]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zheng, N., Pan, C., & Liu, W.
Affiliations
  • Tongde Hospital of Zhejiang Province (CN)
  • Taizhou Municipal Hospital (CN)
Corresponding author
Pan, C
Venue
Journal of International Medical Research
Published
2011-08
Volume
39
Issue
4
Pages
1184-1192
ISSN
  • 0300-0605 (ISSN-L)
  • 1473-2300
OpenAlex
W2317078460
Cited by
28
References
28
Citations by year
2025: 1 · 2024: 1 · 2022: 3 · 2020: 3 · 2019: 1 · 2018: 2 · 2017: 4 · 2016: 4 · 2015: 3 · 2014: 2 · 2013: 2 · 2012: 2
FWCI
2.14
Type
journal article
Language
en
Open access
Locations
  • Journal of International Medical Research (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Reproductive Medicine › Endometriosis Research and Treatment
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
Keywords
endometriosis, serum biomarkers, MALDI-TOF mass spectrometry, serum proteomics, protein biomarkers, endometriosis diagnosis, sensitivity and specificity
MeSH terms
Adult, Blood Proteins, Endometriosis, Female, Humans, Prognosis, Sensitivity and Specificity, Biomarkers, Tumor, Biomarkers, Case-Control Studies, Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization, Proteomics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review