Type III and Type IV Endoleak: Toward a Complete Definition of Blood Flow in the Sac after Endoluminal AAA Repair
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
In this document the authors continue to refine their seminal categorization of endoleak, a major complication of endovascular aneurysm repair. In addition to type I (related to the graft device itself) and type II (retrograde flow from collateral branches) endoleak, they propose two new categories: endoleak due to fabric tears, graft disconnection, or disintegration would be classified type III, and flow through the graft presumed to be associated with graft wall “porosity” would be categorized as type IV endoleak.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
White, G. H., Yu, W., May, J., Chaufour, X., & Stephen, M. S. (1997) · Journal of Endovascular Therapy · doi:10.1177/152660289700400207 · Cited by 771
Self-citationZarins, C. K., for the investigators of the Medtronic AneuRx Multicenter Clinical Trial, White, R. A., Schwarten, D., Kinney, E., Diethrich, E. B., Hodgson, K. J., & Fogarty, T. J. (1999) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(99)70382-4 · Cited by 596
Rupture of abdominal aortic aneurysm previously treated by endovascular stentgraft
Torsello, G. B., Klenk, E., Kasprzak, B., & Umscheid, T. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70214-9 · Cited by 173
An Experimental Model for the Acute and Chronic Evaluation of Intra-Aneurysmal Pressure
Faries, P. L., Sánchez, L. A., Marin, M. L., Parsons, R. E., Lyon, R. T., Oliveri, S., & Veith, F. J. (1997) · Journal of Endovascular Therapy · doi:10.1177/152660289700400310 · Cited by 53
Cited by
Chaikof, E. L., Dalman, R. L., Eskandari, M. K., Jackson, B. M., Lee, W. A., Mansour, M. A., Mastracci, T. M., Mell, M., Murad, M. H., Nguyen, L. L., et al. (2018) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2017.10.044 · Cited by 2,751
Wanhainen, A., Verzini, F., Van Herzeele, I., Allaire, E., Bown, M., Cohnert, T., Dick, F., van Herwaarden, J., Karkos, C., Koelemay, M., et al. (2019) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.09.020 · Cited by 2,326
Reporting standards for endovascular aortic aneurysm repair
Chaikof, E. L., Blankensteijn, J. D., Harris, P. L., White, G. H., Zarins, C. K., Bernhard, V. M., Matsumura, J. S., May, J., Veith, F. J., Fillinger, M. F., et al. (2002) · Journal of Vascular Surgery · doi:10.1067/mva.2002.123763 · Cited by 1,773
Self-citationMoll, F. L., Powell, J. T., Fraedrich, G., Verzini, F., Haulon, S., Waltham, M., van Herwaarden, J. A., Holt, P. J. E., van Keulen, J. W., Rantner, B., et al. (2011) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2010.09.011 · Cited by 1,468
Chaikof, E. L., Brewster, D. C., Dalman, R. L., Makaroun, M. S., Illig, K. A., Sicard, G. A., Timaran, C. H., Upchurch, G. R., & Veith, F. J. (2009) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2009.07.002 · Cited by 732
Metadata
- Authors
- White, G. H., May, J., Waugh, R. C., Chaufour, X., & Yu, W.
- Venue
- Journal of Endovascular Therapy
- Publisher
- SAGE Publications
- Published
- 1998-11
- Volume
- 5
- Issue
- 4
- Pages
- 305-309
- ISSN
- 1526-6028 (ISSN-L)
- 1545-1550
- OpenAlex
- W2140294573
- Cited by
- 390
- References
- 4
- FWCI
- 25.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.