The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Toward Automated, At-Home Assessment of Mobility Among Patients With Parkinson Disease, Using a Body-Worn Accelerometer
Abstract
Objective. To develop an automated and objective method to assess mobility in Parkinson disease (PD) patients in daily-life settings and to investigate whether accelerometer-derived measures discriminate between PD and healthy controls as they walk and simulate activities of daily living (ADL). Methods. Healthy older adults (17) and patients with PD (22) wore a triaxial accelerometer on their lower back during short walks (validation study) and during a walk around the medical center to simulate daily activities (ADL simulation). The variability (consistency and rhythmicity) of stepping was assessed. The patients completed the walks before and after taking their anti-Parkinsonian medications. Frequency-based acceleration measures included dominant frequency, amplitude (strength of signal frequency), width (frequency dispersion), and slope (a combination reflecting amplitude and width) of the main frequency of the power spectral density in the 0.5- to 3.0-Hz band. A subset of the Unified Parkinson-Disease Rating Scale provided a clinical measure of gait impairment (UPDRS-Gait5). A PD patient and control wore the sensors for 3 days at home. Results. The width was larger, and the amplitude and slope were smaller in the PD patients compared to the controls in the validation study and ADL simulation ( P < .02). The width decreased, and the amplitude and slope increased when patients took anti-Parkinsonian medications ( P < .007). Significant correlations were observed between acceleration-derived measures and UPDRS-Gait5. The data obtained at home was similar to the clinic data. Conclusions. Frequency-derived measures are valid and sensitive estimates of stride-to-stride variability that can be used to assess the quality and consistency of walking in patients with PD in real-life settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable Assistant for Parkinson’s Disease Patients With the Freezing of Gait Symptom
Bachlin, M., Plotnik, M., Roggen, D., Maidan, I., Hausdorff, J. M., Giladi, N., & Troster, G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2036165 · Cited by 693 · cited 2×
“The method presented could, theoretically, be adapted to monitors worn on other locations, such as an ankle-worn monitor.(35,40) The results of the present study advance the possibility of using an accelerometer to monitor real-world mobility.”
BackgroundSelf-citationSalarian, A., Russmann, H., Wider, C., Burkhard, P. R., Vingerhoets, F. J. G., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.886670 · Cited by 416
Frenkel-Toledo, S., Giladi, N., Peretz, C., Herman, T., Gruendlinger, L., & Hausdorff, J. M. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-23 · Cited by 285
Ambulatory monitoring of physical activities in patients with Parkinson’s disease
Salarian, A., Russmann, H., Vingerhoets, F. J. G., Burkhard, P. R., & Aminian, K. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.896591 · Cited by 217
Sleep Disruption in Parkinson's Disease: Assessment by Continuous Activity Monitoring
van Hilten, B. (1994) · Archives of Neurology · doi:10.1001/archneur.1994.00540210094018 · Cited by 166
Prajapati, S. K., Gage, W. H., Brooks, D., Black, S. E., & McIlroy, W. E. (2011) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968310374189 · Cited by 86
Cited by
Smart wearable body sensors for patient self-assessment and monitoring
Appelboom, G., Camacho, E., Abraham, M. E., Bruce, S. S., Dumont, E. L., Zacharia, B. E., D’Amico, R., Slomian, J., Reginster, J. Y., Bruyère, O., et al. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-28 · Cited by 448
How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review
Rovini, E., Maremmani, C., & Cavallo, F. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00555 · Cited by 426
Quantitative wearable sensors for objective assessment of Parkinson's disease
Maetzler, W., Domingos, J., Srulijes, K., Ferreira, J. J., & Bloem, B. R. (2013) · Movement Disorders · doi:10.1002/mds.25628 · Cited by 374
Free‐living monitoring of Parkinson's disease: Lessons from the field
Del Din, S., Godfrey, A., Mazzà, C., Lord, S., & Rochester, L. (2016) · Movement Disorders · doi:10.1002/mds.26718 · Cited by 370
Del Din, S., Godfrey, A., Galna, B., Lord, S., & Rochester, L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0154-5 · Cited by 349
Metadata
- Authors
- Weiss, A., Sharifi, S., Plotnik, M., van Vugt, J. P. P., Giladi, N., & Hausdorff, J. M.
- Venue
- Neurorehabilitation and Neural Repair
- Publisher
- SAGE Publications
- Published
- 2011-10-11
- Volume
- 25
- Issue
- 9
- Pages
- 810-818
- ISSN
- 0888-4390 (ISSN-L)
- 1545-9683
- 1552-6844
- OpenAlex
- W2070159246
- Cited by
- 197
- References
- 6
- FWCI
- 28.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward Automated, At-Home Assessment of Mobility Among Patients With Parkinson Disease, Using a Body-Worn Accelerometer. https://app.cochat.ai/papers/10.1177/1545968311424869
- The paper
- Weiss, A., Sharifi, S., Plotnik, M., van Vugt, J. P. P., Giladi, N., & Hausdorff, J. M. (2011). Toward Automated, At-Home Assessment of Mobility Among Patients With Parkinson Disease, Using a Body-Worn Accelerometer. Neurorehabilitation and Neural Repair. https://doi.org/10.1177/1545968311424869
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.