3D Statistical Parametric Mapping of EEG Source Spectra by Means of Variable Resolution Electromagnetic Tomography (VARETA)
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
This article describes a new method for 3D QEEG tomography in the frequency domain. A variant of Statistical Parametric Mapping is presented for source log spectra. Sources are estimated by means of a Discrete Spline EEG inverse solution known as Variable Resolution Electromagnetic Tomography (VARETA). Anatomical constraints are incorporated by the use of the Montreal Neurological Institute (MNI) probabilistic brain atlas. Efficient methods are developed for frequency domain VARETA in order to estimate the source spectra for the set of 10 3–10 5 voxels that comprise an EEG/MEG inverse solution. High resolution source Z spectra are then defined with respect to the age dependent mean and standard deviations of each voxel, which are summarized as regression equations calculated from the Cuban EEG normative database. The statistical issues involved are addressed by the use of extreme value statistics. Examples are shown that illustrate the potential clinical utility of the methods herein developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
Collins, D. L., Neelin, P., Peters, T. M., & Evans, A. C. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199403000-00005 · Cited by 3,431
Electroencephalography—Basic principles, clinical applications and related fields
(1982) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(82)90067-4 · Cited by 3,427
Pascual-Marqui, R. D., Michel, C. M., & Lehmann, D. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(84)90014-x · Cited by 2,869
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Dale, A. M., & Sereno, M. I. (1993) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1993.5.2.162 · Cited by 2,003
Electroencephalography: Basic Principles, Clinical Applications and Related Fields
Torres, F. (1983) · Archives of Neurology · doi:10.1001/archneur.1983.04050030085025 · Cited by 1,812
A Probabilistic Atlas of the Human Brain: Theory and Rationale for Its Development
Mazziotta, J. C., Toga, A. W., Evans, A., Fox, P., & Lancaster, J. (1995) · NeuroImage · doi:10.1006/nimg.1995.1012 · Cited by 1,584
3D statistical neuroanatomical models from 305 MRI volumes
Evans, A. C., Collins, D. L., Mills, S. R., Brown, E. D., Kelly, R. L., & Peters, T. M. (2005) · 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference · doi:10.1109/nssmic.1993.373602 · Cited by 1,487
Cited by
Effective connectivity: Influence, causality and biophysical modeling
Valdes-Sosa, P. A., Roebroeck, A., Daunizeau, J., & Friston, K. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.058 · Cited by 390
Moore, A., Gruber, T., Derose, J., & Malinowski, P. (2012) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2012.00018 · Cited by 317
Babiloni, C., Barry, R. J., Başar, E., Blinowska, K. J., Cichocki, A., Drinkenburg, W. H. I. M., Klimesch, W., Knight, R. T., Lopes da Silva, F., Nunez, P., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.06.234 · Cited by 314
Cerebral response to patient's own name in the vegetative and minimally conscious states
Di, H. B., Yu, S. M., Weng, X. C., Laureys, S., Yu, D., Li, J. Q., Qin, P. M., Zhu, Y. H., Zhang, S. Z., & Chen, Y. Z. (2007) · Neurology · doi:10.1212/01.wnl.0000258544.79024.d0 · Cited by 291
Invariant Reversible QEEG Effects of Anesthetics
John, E. R., Prichep, L. S., Kox, W., Valdés-Sosa, P., Bosch-Bayard, J., Aubert, E., Tom, M., diMichele, F., & Gugino, L. D. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0507 · Cited by 274
Self-citationThe neurophysics of consciousness
John, E. R. (2002) · Brain Research Reviews · doi:10.1016/s0165-0173(02)00142-x · Cited by 262
Self-citationBayesian model averaging in EEG/MEG imaging
Trujillo-Barreto, N. J., Aubert-Vázquez, E., & Valdés-Sosa, P. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.11.008 · Cited by 262
Self-citationFunctional coupling of simultaneous electrical and metabolic activity in the human brain
Oakes, T. R., Pizzagalli, D. A., Hendrick, A. M., Horras, K. A., Larson, C. L., Abercrombie, H. C., Schaefer, S. M., Koger, J. V., & Davidson, R. J. (2004) · Human Brain Mapping · doi:10.1002/hbm.20004 · Cited by 235
“There are multiple approaches to this problem [Baillet et al., 2001; Bosch-Bayard et al., 2001; Gorodnitsky et al., 1995]; based on previous work in our laboratory [e.g., Pizzagalli et al., 2001, 2002a], we selected the low-resolution electromagnetic tomography (LORETA) algorithm [Pascual-Marqui,…”
MethodElectroencephalography and High-Density Electrophysiological Source Localization
Pizzagalli, D. A. (2009) · Handbook of Psychophysiology · doi:10.1017/cbo9780511546396.003 · Cited by 226
“Variable resolution electromagnetic tomography (VARETA) Frequency-domain VARETA is a discrete, spline distributed solution11 that has been used to estimate sources of EEG frequency bands (Valdes-Sosa, Marti, Garcia, & Casanova, 1996; Bosch-Bayard et al., 2001).”
BackgroundMethodA field theory of consciousness.
John, E. R. (2001) · Consciousness and Cognition · doi:10.1006/ccog.2001.0508 · Cited by 214
“Representative mean VARETA (Bosch-Bayard et al., 2001) images, averaged across 15 patients, of serial slices from a statistical MRI atlas (Evans, 1993).”
BackgroundMethodInfluentialSelf-citationModel driven EEG/fMRI fusion of brain oscillations
Valdes‐Sosa, P. A., Sanchez‐Bornot, J. M., Sotero, R. C., Iturria‐Medina, Y., Aleman‐Gomez, Y., Bosch‐Bayard, J., Carbonell, F., & Ozaki, T. (2009) · Human Brain Mapping · doi:10.1002/hbm.20704 · Cited by 205
“The estimate of power at the alpha peak of the nPCD was obtained by means of the VARETA inverse solution [Bosch-Bayard et al., 2001].”
BackgroundMethodSelf-citationAndersen, S. K., & Müller, M. M. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1002436107 · Cited by 192
“Cortical sources of SSVEPs were localized by means of variable resolution electromagnetic tomography (18) and statistically compared between attentional conditions for the time range from 200 to 1,500 ms after the cue.”
MethodSanMiguel, I., Saupe, K., & Schröger, E. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00407 · Cited by 89
“Brain sources for the relevant ERP responses were estimated performing brain electrical tomography analyses, using the Variable Resolution Electromagnetic Tomography (VARETA, Bosch-Bayard et al., 2001) approach.”
MethodRapid extraction of auditory feature contingencies
Bendixen, A., Prinz, W., Horváth, J., Trujillo-Barreto, N. J., & Schröger, E. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.040 · Cited by 88
“Aiming to reveal the MMN generators, brain electrical tomography analyses were applied by means of the VARETA approach (Bosch-Bayard et al., 2001; Valdés-Sosa et al., 2000).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Bosch-Bayard, J., Valdés-Sosa, P., Virues-Alba, T., Aubert-Vázquez, E., John, E. R., Harmony, T., Riera-Díaz, J., & Trujillo-Barreto, N.
- Venue
- Clinical Electroencephalography
- Publisher
- SAGE Publications
- Published
- 2001-04
- Volume
- 32
- Issue
- 2
- Pages
- 47-61
- ISSN
- 0009-9155 (ISSN-L)
- OpenAlex
- W2022636131
- Cited by
- 216
- References
- 56
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.