Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 187

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Brachial Flow-Mediated Vasodilator Responses in Population-Based Research: Methods, Reproducibility and Effects of Age, Gender and Baseline Diameter

Herrington, D. M., Fan, L., Drum, M., Riley, W. A., Pusser, B. E., Crouse, J. R., Burke, G. L., McBurnie, M. A., Morgan, T. M., Espeland, M. A.·2001·European Journal of Cardiovascular Prevention & Rehabilitation

Abstract

BACKGROUND: Brachial artery ultrasound has been proposed as an inexpensive, accurate way to assess cardiovascular risk in populations. However, analysis and interpretation of these data are not uniform. METHODS: We analysed the relationship between relative and absolute changes in brachial artery diameter in response to flow-mediated dilation and age, gender and baseline diameter among 4,040 ultrasound examinations from subjects aged 14 to 98 years. RESULTS: Reproducibility studies demonstrated intra- and interreader and intrasubject correlations from 0.67 to 0.84 for repeated measures of per cent change in diameter. Per cent change in diameter after flow stimulus was 3.58 +/- 0.10% (mean +/- standard deviation). Corresponding values for baseline diameter and absolute change in diameter were 4.43 +/- 0.87 mm and 0.15 +/- 0.01 mm, respectively. Baseline diameter and its variance were inversely related to per cent change in diameter (P< 0.001). In contrast, absolute change in diameter was more uniform throughout the range of baseline diameters. Baseline diameter was directly related, and per cent change in diameter inversely related, to age (P < 0.001 for all three measures). Time to maximum vasodilator response increased with age (P < 0.001). Women (n=2,315) had significantly larger per cent change in diameter than men (n=1,725) (P < 0.001). However, after adjustment for age and baseline diameter, per cent and absolute change were 5% smaller in women than men (P < 0.05 for both). In multivariate analysis, age was overwhelmingly the most important determinant of absolute change in diameter (P < 0.001). CONCLUSIONS: Automated analysis of brachial flow-mediated vasodilator responses is both feasible and reproducible in large-scale clinical and population-based research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/174182670100800512

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 187

Metadata

Authors
Herrington, D. M., Fan, L., Drum, M., Riley, W. A., Pusser, B. E., Crouse, J. R., Burke, G. L., McBurnie, M. A., Morgan, T. M., & Espeland, M. A.
Venue
European Journal of Cardiovascular Prevention & Rehabilitation
Published
2001-10-01
Volume
8
Issue
5
Pages
319-328
ISSN
  • 1741-8267 (ISSN-L)
  • 1741-8275
OpenAlex
W2113323082
Cited by
187
References
2
FWCI
5.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Brachial Flow-Mediated Vasodilator Responses in Population-Based Research: Methods, Reproducibility and Effects of Age, Gender and Baseline Diameter. https://app.cochat.ai/papers/10.1177/174182670100800512
The paper
Herrington, D. M., Fan, L., Drum, M., Riley, W. A., Pusser, B. E., Crouse, J. R., Burke, G. L., McBurnie, M. A., Morgan, T. M., & Espeland, M. A. (2001). Brachial Flow-Mediated Vasodilator Responses in Population-Based Research: Methods, Reproducibility and Effects of Age, Gender and Baseline Diameter. European Journal of Cardiovascular Prevention & Rehabilitation. https://doi.org/10.1177/174182670100800512

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.