The DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.
Does Needle Size Matter?
Open accessAbstract
Hypodermic needles are in widespread use, but patients are unhappy with the pain, anxiety, and difficulty of using them. To increase patient acceptance, smaller needle diameters and lower insertion forces have been shown to reduce the frequency of painful injections. Guided by these observations, fine needles and microneedles have been developed to minimize pain and have found the greatest utility for delivery of vaccines and biopharmaceuticals such as insulin. However, pain reduction must be balanced against limitations of injection depth, volume, and formulations introduced by reduced needle dimensions. In some cases, needle-free delivery methods provide useful alternatives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While typical needle sizes range from 21-gauge (21G) to 23-gauge (23G), opting for a smaller needle size such as a 25-gauge (25G) can reduce needle insertion force minimizing patient discomfort (Gill and Prausnitz, 2007;Patout et al., 2015)”
From Evaluation of a novel blood collection set for venipuncture in oncology patients with difficult venous access: Impact on sample quality, phlebotomist satisfaction and patient pain perception (2024) · cites this paper as Gill and Prausnitz, 2007
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kroger, A. T., ATKINSON, W. L., Marcuse, E. K., & Pickering, L. K. (1994) · PsycEXTRA Dataset · doi:10.1037/e546992006-001 · Cited by 1,712
Current status and future potential of transdermal drug delivery
Prausnitz, M. R., Mitragotri, S., & Langer, R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1304 · Cited by 1,463
Self-citationDavis, S. P., Landis, B. J., Adams, Z., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 941
Self-citationLack of Pain Associated with Microfabricated Microneedles
Kaushik, S., Hord, A. H., Denson, D. D., McAllister, D. V., Smitra, S., Allen, M. G., & Prausnitz, M. R. (2001) · Anesthesia & Analgesia · doi:10.1213/00000539-200102000-00041 · Cited by 578
Self-citationThe Cutaneous Microcirculation
Braverman, I. M. (2000) · Journal of Investigative Dermatology Symposium Proceedings · doi:10.1046/j.1087-0024.2000.00010.x · Cited by 488
The global burden of disease attributable to contaminated injections given in health care settings
Hauri, A. M., Armstrong, G. L., & Hutin, Y. J. (2003) · International Journal of STD & AIDS · doi:10.1258/095646204322637182 · Cited by 456
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
Hollow Metal Microneedles for Insulin Delivery to Diabetic Rats
Davis, S. P., Martanto, W., Allen, M. G., & Prausnitz, M. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845240 · Cited by 407
Self-citationCurrent status and future prospects of needle-free liquid jet injectors
Mitragotri, S. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2076 · Cited by 383
Percutaneous Penetration Enhancers
(2005) · CRC Press eBooks · doi:10.1201/9781420039207 · Cited by 373
Fear of needles and vasovagal reactions among phlebotomy patients
Deacon, B. J., & Abramowitz, J. S. (2006) · Journal of Anxiety Disorders · doi:10.1016/j.janxdis.2006.01.004 · Cited by 197
Pain following controlled cutaneous insertion of needles with different diameters
Arendt‐Nielsen, L., Egekvist, H., & Bjerring, P. (2006) · Somatosensory & Motor Research · doi:10.1080/08990220600700925 · Cited by 197
Touítou, E., & Barry, B. W. (2006) · CRC Press eBooks · doi:10.1201/9781420004816 · Cited by 190
Mikszta, J. A., Sullivan, V. J., Dean, C. H., Waterston, A. M., Alarcon, J. B., Dekker, J. P., Brittingham, J. M., Huang, J., Hwang, C. R., Ferriter, M. S., et al. (2004) · The Journal of Infectious Diseases · doi:10.1086/426865 · Cited by 159
Cross, S. E., & Roberts, M. S. (2004) · Current Drug Delivery · doi:10.2174/1567201043480045 · Cited by 152
Preclinical Evaluation of Microneedle Technology for Intradermal Delivery of Influenza Vaccines
Alarcon, J. B., Hartley, A. W., Harvey, N. G., & Mikszta, J. A. (2007) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00387-06 · Cited by 151
Microneedle Insertion Force Reduction Using Vibratory Actuation
Yang, M., & Zahn, J. D. (2004) · Biomedical Microdevices · doi:10.1023/b:bmmd.0000042046.07678.2e · Cited by 128
Pain and mechanical injury of human skin following needle insertions
Egekvist, H., Bjerring, P., & Arendt‐Nielsen, L. (1999) · European Journal of Pain · doi:10.1016/s1090-3801(99)90187-8 · Cited by 118
Nordquist, L., Roxhed, N., Griss, P., & Stemme, G. (2007) · Pharmaceutical Research · doi:10.1007/s11095-007-9256-x · Cited by 118
Insulin delivery using pen devices
Bohannon, N. J. V. (1999) · Postgraduate Medicine · doi:10.3810/pgm.1999.10.15.751 · Cited by 112
Berlin, I., Bisserbe, J. C., Eiber, R., Balssa, N., Sachon, C., Bosquet, F., & Grimaldi, A. (1997) · Diabetes Care · doi:10.2337/diacare.20.2.176 · Cited by 102
Schwartz, S. L., Hassman, D. R., Shelmet, J. J., Sievers, R., Weinstein, R. L., Liang, J. Z., & Lyness, W. H. (2004) · Clinical Therapeutics · doi:10.1016/j.clinthera.2004.10.007 · Cited by 89
Delmar's Comprehensive Medical Assisting: Administrative and Clinical Competencies
Lindh, W. Q. (1997) · Medical Entomology and Zoology · Cited by 82
Reducing injection pain in children and adolescents with diabetes: a review of indwelling catheters
Hanås, R. (2004) · Pediatric Diabetes · doi:10.1111/j.1399-543x.2004.00048.x · Cited by 45
宮腰, 将., Kamoi, K., Iwanaga, M., Hoshiyama, A., & Yamada, A. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100516 · Cited by 27
First approved inhaled insulin therapy for diabetes mellitus
Jani, R., Triplitt, C. L., Reasner, C. A., & DeFronzo, R. A. (2006) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.4.1.63 · Cited by 20
Kravetz, R. E. (2005) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2005.00397.x · Cited by 15
Egekvist, H., Bjerring, P., & Arendt‐Nielsen, L. (1999) · Skin Research and Technology · doi:10.1111/j.1600-0846.1999.tb00137.x · Cited by 15
Research works printed but not linked: 3
- Kroger A, MMWR Recomm Rep, 55
- Schneider LW, Peck LS, Melvin JW. Penetration characteristics of hypodermic needles in skin and muscle tissue. Phase I (Appendices B-E). Final report. Highway Safety Research Institute, Ann Arbor, MI; 1978. Persistent URL http://hdl.handle.net/2027.42/614.
- Gupta J, Felner E, Prausnitz MR. Microneedles for minimally invasive transdermal insulin delivery: An in vivo study in human diabetic subjects. Proceedings of the 6th Annual Diabetes Technology Meeting; 2006.
Cited by
Sorted by citations
Engineering Microneedle Patches for Vaccination and Drug Delivery to Skin
Prausnitz, M. R. (2017) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-060816-101514 · Cited by 451
Self-citationMinimally Invasive Protein Delivery with Rapidly Dissolving Polymer Microneedles
Sullivan, S. P., Murthy, N., & Prausnitz, M. R. (2008) · Advanced Materials · doi:10.1002/adma.200701205 · Cited by 392
Self-citationMicroneedle-Based Delivery: An Overview of Current Applications and Trends
Guillot, A. J., Cordeiro, A. S., Donnelly, R. F., Montesinos, M. C., Garrigues, T., & Melero, A. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060569 · Cited by 262
Injectable controlled release depots for large molecules
Schwendeman, S. P., Shah, R. B., Bailey, B. A., & Schwendeman, A. S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.057 · Cited by 223
Lutton, R. E. M., Moore, J. V., Larrañeta, E., Ligett, S., Woolfson, A. D., & Donnelly, R. F. (2015) · Drug Delivery and Translational Research · doi:10.1007/s13346-015-0237-z · Cited by 163
Metadata
- Authors
- Gill, H. S., & Prausnitz, M. R.
- Affiliations
- Georgia Institute of Technology (US)
- Corresponding author
- Prausnitz, Mark R.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2007-09
- Volume
- 1
- Issue
- 5
- Pages
- 725-729
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC2769648
- OpenAlex
- W2148727825
- Cited by
- 164
- References
- 29
- Citations by year
- 2026: 10 · 2025: 10 · 2024: 11 · 2023: 16 · 2022: 14 · 2021: 16 · 2020: 16 · 2019: 13 · 2018: 5 · 2017: 10 · 2016: 8 · 2015: 13 · 2014: 3 · 2013: 7 · 2012: 3
- FWCI
- 0.72
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Pfizer
- Topics
- Health Sciences › Medicine › Emergency Medicine › Intramuscular injections and effects
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Keywords
- needle size, hypodermic needle, injection pain, microneedles, fine needle, insulin delivery, vaccine delivery, biopharmaceutical delivery, injection depth, patient acceptance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review