CoChat

Self-Monitoring of Blood Glucose in Type 1 Diabetes Patients with Insufficient Metabolic Control: Focused Self-Monitoring of Blood Glucose Intervention Can Lower Glycated Hemoglobin A1C

Open access
Skeie, Svein, Kristensen, Gunn B. B., Carlsen, Siri, Sandberg, Sverre · 2009 · Journal of Diabetes Science and Technology
Cited by 51

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective: Little attention has been given and few studies have been published focusing on how to optimize self-monitoring of blood glucose (SMBG) use to monitor daily therapy for persons with type 1 diabetes mellitus. This study was designed to evaluate the effect on glycated hemoglobin (A1C) of a structured intervention focused on SMBG in type 1 diabetes patients with insufficient metabolic control (A1C ≥ 8%) using a randomized clinical trial design. Method: One hundred fifty-nine outpatients with type 1 diabetes on multiple injection therapy with insulin and A1C ≥8% were recruited and randomized to one group receiving a focused, structured 9-month SMBG intervention ( n = 59) and another group receiving regular care based on guidelines ( n = 64). Results: Glycated hemoglobin values (mean % ± standard deviation) at study start was similar: 8.65 ± 0.10 in the intervention group and 8.61 ± 0.09 in the control group. The two groups were comparable (age, gender, body mass index, complication rate, and treatment modality) at study start and had mean diabetes duration and SMBG experience of 19 and 20 years, respectively. At study end, there was decrease in A1C in the intervention group ( p < .05), and the A1C was 0.6% lower compared with the control group (p < .05). No increase in the number of minor or major hypoglycemia episodes was observed in the intervention group during the study period. Conclusions: A simple, structured, focused SMBG intervention improved metabolic control in patients with longstanding diabetes type 1 and A1C ≥ 8%. The intervention was based on general recommendations, realistic in format, and can be applied in a regular outpatient setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229680900300109

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 51

Metadata

Authors
Skeie, S., Kristensen, G. B. B., Carlsen, S., & Sandberg, S.
Venue
Journal of Diabetes Science and Technology
Published
2009-01
Volume
3
Issue
1
Pages
83-88
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2096637594
Cited by
51
References
3
FWCI
1.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-Monitoring of Blood Glucose in Type 1 Diabetes Patients with Insufficient Metabolic Control: Focused Self-Monitoring of Blood Glucose Intervention Can Lower Glycated Hemoglobin A1C. https://app.cochat.ai/papers/10.1177/193229680900300109
The paper
Skeie, S., Kristensen, G. B. B., Carlsen, S., & Sandberg, S. (2009). Self-Monitoring of Blood Glucose in Type 1 Diabetes Patients with Insufficient Metabolic Control: Focused Self-Monitoring of Blood Glucose Intervention Can Lower Glycated Hemoglobin A1C. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229680900300109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.