Practical Aspects of Insulin Pen Devices
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Insulin pen devices have several advantages over the traditional vial-and-syringe method of insulin delivery, including improved patient satisfaction and adherence, greater ease of use, superior accuracy for delivering small doses of insulin, greater social acceptability, and less reported injection pain. In recent years, pens have become increasingly user-friendly, and some models are highly intuitive to use, requiring little or no instruction. Despite this progress, uptake of these devices in the United States has not matched that in many other areas of the world. There is a need for improved awareness of the current characteristics of insulin pen devices among United States health care professionals. Knowledge of the design improvements that have been incorporated into pens, both to address patient needs and as a result of the improved technology behind the device mechanics, is essential to promoting the use of insulin pen devices. This review highlights some of the practical aspects of pen use and discusses the factors to be considered when selecting among different insulin pens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Korytkowski, M., Bell, D., Jacobsen, C., Suwannasari, R., & FlexPen® Study Team (2003) · Clinical Therapeutics · doi:10.1016/s0149-2918(03)80337-5 · Cited by 267
Cited by
Davies, M. J., Gagliardino, J. J., Gray, L. J., Khunti, K., Mohan, V., & Hughes, R. (2013) · Diabetic Medicine · doi:10.1111/dme.12128 · Cited by 294
Zaykov, A. N., Mayer, J. P., & DiMarchi, R. D. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2015.36 · Cited by 287
Evolution of Insulin Delivery Devices: From Syringes, Pens, and Pumps to DIY Artificial Pancreas
Kesavadev, J., Saboo, B., Krishna, M. B., & Krishnan, G. (2020) · Diabetes Therapy · doi:10.1007/s13300-020-00831-z · Cited by 221
Model Study of the Pressure Build-Up during Subcutaneous Injection
Thomsen, M., Hernandez-Garcia, A., Mathiesen, J., Poulsen, M., Sørensen, D. N., Tarnow, L., & Feidenhans'l, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104054 · Cited by 65
“To our knowledge the infusion pressure has not been measured for subcutaneous injections at injection speeds of the order 100 mL/s, which is the common infusion rate using an insulin pen [16].”
MethodEvolution of Devices in Diabetes Management
Penfornis, A., Personeni, E., & Borot, S. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0058 · Cited by 49
“6 However, it has been shown that despite the higher unit cost of insulin in pen devices versus vials, overall diabetes-related treatment costs are lower with pen devices than with vial and syringe, because of factors such as fewer hospital visits.”
Metadata
- Authors
- Pearson, T. L.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-05
- Volume
- 4
- Issue
- 3
- Pages
- 522-531
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2023853264
- Cited by
- 94
- References
- 1
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.