Update on Mathematical Modeling Research to Support the Development of Automated Insulin Delivery Systems
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
One year after its initial meeting, the Glycemia Modeling Working Group reconvened during the 2009 Diabetes Technology Meeting in San Francisco, CA. The discussion, involving 39 scientists, again focused on the need for individual investigators to have access to the clinical data required to develop and refine models of glucose metabolism, the need to understand the differences among the distinct models and control algorithms, and the significance of day-to-day subject variability. The key conclusion was that model-based comparisons of different control algorithms, or the models themselves, are limited by the inability to access individual model–patient parameters. It was widely agreed that these parameters, as opposed to the average parameters that are typically reported, are necessary to perform such comparisons. However, the prevailing view was that, if investigators were to make the parameters available, it would limit their ability (and that of their institution) to benefit from the invested work in developing their models. A general agreement was reached regarding the importance of each model having an insulin pharmacokinetic/pharmacodynamic profile that is not different from profiles reported in the literature (88% of the respondents agreed that the model should have similar curves or be analyzed separately) and the importance of capturing intraday variance in insulin sensitivity (91% of the respondents indicated that this could result in changes in fasting glucose of ≥15%, with 52% of the respondents believing that the variability could effect changes of ≥30%). Seventy-six percent of the participants indicated that high-fat meals were thought to effect changes in other model parameters in addition to gastric emptying. There was also widespread consensus as to how a closed-loop controller should respond to day-to-day changes in model parameters (with 76% of the participants indicating that fasting glucose should be within 15% of target, with 30% of the participants believing that it should be at target). The group was evenly divided as to whether the glucose sensor per se continues to be the major obstacle in achieving closed-loop control. Finally, virtually all participants agreed that a future two-day workshop should be organized to compare, contrast, and understand the differences among the different models and control algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760 · cited 3×
“[2] Typically is within 15% if the subject has accurately administered insulin for all meals during the previous day and not eaten for 10 h.”
BackgroundInfluentialPartitioning glucose distribution/transport, disposal, and endogenous production during IVGTT
Hovorka, R., Shojaee-Moradie, F., Carroll, P. V., Chassin, L. J., Gowrie, I. J., Jackson, N. C., Tudor, R. S., Umpleby, A. M., & Jones, R. H. (2002) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00304.2001 · Cited by 393
Mudaliar, S. R., Lindberg, F. A., Joyce, M., Beerdsen, P., Strange, P., Lin, A., & Henry, R. R. (1999) · Diabetes Care · doi:10.2337/diacare.22.9.1501 · Cited by 276
Simulation Environment to Evaluate Closed-Loop Insulin Delivery Systems in Type 1 Diabetes
Wilinska, M. E., Chassin, L. J., Acerini, C. L., Allen, J. M., Dunger, D. B., & Hovorka, R. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400117 · Cited by 244 · cited 1×
“[3] No, the simulation model should represent extreme cases that can potentially be encountered in the real population.”
BackgroundClarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185
Swan, K. L., Dziura, J. D., Steil, G. M., Voskanyan, G. R., Sikes, K. A., Steffen, A. T., Martin, M. L., Tamborlane, W. V., & Weinzimer, S. A. (2009) · Diabetes Care · doi:10.2337/dc08-0595 · Cited by 82
Self-citationZisser, H. (2008) · Diabetes Care · doi:10.2337/dc07-1757 · Cited by 44
Cited by
A review of personalized blood glucose prediction strategies for T1DM patients
Oviedo, S., Vehí, J., Calm, R., & Armengol, J. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2833 · Cited by 279
“reliable AP is the lack of BG prediction models that are reliable enough to model the variance of a diabetic patient's physiology.(19) A fully reliable model should not only be able to mimic the patient's physiology but also cope with external disturbances, such as noise, exercise, unannounced meals,(20) and stress, a…”
BackgroundRebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
Self-citationModeling impulsive injections of insulin: towards artificial pancreas
Huang, M., Li, J., Song, X., & Guo, H. (2012) · SIAM Journal on Applied Mathematics · doi:10.1137/110860306 · Cited by 119
Modeling impulsive insulin delivery in insulin pump with time delays
Song, X., Huang, M., & Li, J. (2014) · SIAM Journal on Applied Mathematics · doi:10.1137/130933137 · Cited by 35
Metadata
- Authors
- Steil, G. M., Hipszer, B., & Reifman, J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-05
- Volume
- 4
- Issue
- 3
- Pages
- 759-769
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W4238770017
- Cited by
- 27
- References
- 7
- Type
- conference abstract
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Update on Mathematical Modeling Research to Support the Development of Automated Insulin Delivery Systems. https://app.cochat.ai/papers/10.1177/193229681000400334
- The paper
- Steil, G. M., Hipszer, B., & Reifman, J. (2010). Update on Mathematical Modeling Research to Support the Development of Automated Insulin Delivery Systems. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681000400334
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.