Quantifying the Composition of Human Skin for Glucose Sensor Development
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Glucose is heterogeneously distributed within human skin. In order to develop a glucose measurement method for human skin, both a good quantification of the different compartments of human skin and an understanding of glucose transport processes are essential. This study focused on the composition of human skin. In addition, the extent to which intersubject variability in skin composition alters glucose dynamics in human skin was investigated. Methods: To quantify the composition of the three layers of human skin—epidermis, dermis, and adipose tissue—cell and blood vessel volumes were calculated from skin biopsies. These results were combined with data from the literature. The composition was applied as input for a previously developed computational model that calculates spatiotemporal glucose dynamics in human skin. The model was used to predict the physiological effects of intersubject variability in skin composition on glucose profiles in human skin. Results: According to the model, the lag time of glucose dynamics in the epidermis was sensitive to variation in the volumes of interstitial fluid, cells, and blood of all layers. Data showed most variation/uncertainty in the volume composition of the adipose tissue. This variability mainly influences the dynamics in the adipose tissue. Conclusions: This study identified the intersubject variability in human skin composition. The study shows that this variability has significant influence on the glucose dynamics in human skin. In addition, it was determined which volumes are most critical for the quantification and interpretation of measurements in the different layers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Variability of Insulin Absorption and Insulin Action
Heinemann, L. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502320798312 · Cited by 267
Cited by
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 258
Review of Non-Invasive Glucose Sensing Techniques: Optical, Electrical and Breath Acetone
Shokrekhodaei, M., & Quinones, S. (2020) · Sensors · doi:10.3390/s20051251 · Cited by 221
Zheng, M., Wang, Z., Chang, H., Wang, L., Chew, S. W. T., Lio, D. C. S., Cui, M., Liu, L., Tee, B. C. K., & Xu, C. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901683 · Cited by 207
Metadata
- Authors
- Groenendaal, W., von Basum, G., Schmidt, K. A., Hilbers, P. A. J., & van Riel, N. A. W.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2010-09
- Volume
- 4
- Issue
- 5
- Pages
- 1032-1040
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2106388474
- Cited by
- 79
- References
- 1
- Type
- conference abstract
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.