A Review of the Security of Insulin Pump Infusion Systems
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Insulin therapy has enabled patients with diabetes to maintain blood glucose control to lead healthier lives. Today, rather than injecting insulin manually using syringes, a patient can use a device such as an insulin pump to deliver insulin programmatically. This allows for more granular insulin delivery while attaining blood glucose control. Insulin pump system features have increasingly benefited patients, but the complexity of the resulting system has grown in parallel. As a result, security breaches that can negatively affect patient health are now possible. Rather than focus on the security of a single device, we concentrate on protecting the security of the entire system. In this article, we describe the security issues as they pertain to an insulin pump system that includes an embedded system of components, which include the insulin pump, continuous glucose management system, blood glucose monitor, and other associated devices (e.g., a mobile phone or personal computer). We detail not only the growing wireless communication threat in each system component, but also describe additional threats to the system (e.g., availability and integrity). Our goal is to help create a trustworthy infusion pump system that will ultimately strengthen pump safety, and we describe mitigating solutions to address identified security issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Defective awakening response to nocturnal hypoglycemia in patients with type 1 diabetes mellitus
Schultes, B., Jauch-Chara, K., Gais, S., Hallschmid, M., Reiprich, E., Kern, W., Oltmanns, K. M., Peters, A., Fehm, H. L., & Born, J. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040069 · Cited by 100 · cited 1×
“Hypoglycemic patients do not respond well to auditory alarms [14], and a dual-mode alarm may be necessary (e.”
Background
Cited by
Telemedicine in the face of the COVID-19 pandemic
Vidal-Alaball, J., Acosta-Roja, R., Pastor Hernández, N., Sanchez Luque, U., Morrison, D., Narejos Pérez, S., Perez-Llano, J., Salvador Vèrges, A., & López Seguí, F. (2020) · Atención Primaria · doi:10.1016/j.aprim.2020.04.003 · Cited by 351
For Telehealth To Succeed, Privacy And Security Risks Must Be Identified And Addressed
Hall, J. L., & McGraw, D. (2014) · Health Affairs · doi:10.1377/hlthaff.2013.0997 · Cited by 297
Cybersecurity for Connected Diabetes Devices
Klonoff, D. C. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815583334 · Cited by 79
Self-citationA novel deep learning strategy for classifying different attack patterns for deep brain implants
Rathore, H., Al-Ali, A. K., Mohamed, A., Du, X., & Guizani, M. (2019) · IEEE Access · doi:10.1109/access.2019.2899558 · Cited by 65
“A few reviews have considered such an attack of listening stealthily or eavesdropping to steal patients’ information [13], [14].”
BackgroundPfützner, A., Weissmann, J., Mougiakakou, S., Daskalaki, E., Weis, N., & Ziegler, R. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0278 · Cited by 19
Metadata
- Authors
- Paul, N., Kohno, T., & Klonoff, D. C.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2011-11
- Volume
- 5
- Issue
- 6
- Pages
- 1557-1562
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2143636917
- Cited by
- 68
- References
- 1
- FWCI
- 16.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of the Security of Insulin Pump Infusion Systems. https://app.cochat.ai/papers/10.1177/193229681100500632
- The paper
- Paul, N., Kohno, T., & Klonoff, D. C. (2011). A Review of the Security of Insulin Pump Infusion Systems. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681100500632
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.