CoChat

Partial Pressure of Oxygen in Capillary Blood Samples from the Fingertip

Open access
Freckmann, Guido, Schmid, Christina, Baumstark, Annette, Pleus, Stefan, Link, Manuela, Haug, Cornelia · 2013 · Journal of Diabetes Science and Technology
Cited by 23

The DOI matches its Crossref record.

Abstract

Many people with diabetes routinely measure their blood glucose (BG) on capillary blood samples from the fingertip. Beside other interfering factors, the blood samples’ partial pressure of oxygen (pO2) can affect BG measurements, particularly in systems based on glucose oxidase (GOx) enzyme reactions on test strips.1,2 Indeed, many of the available home-use systems for self-monitoring of blood glucose (SMBG) utilize the GOx enzyme reaction, which is prone to oxygen interference; however, in the literature, poor information is available concerning physiological pO2 values and possible variations in capillary blood from the fingertip in people with diabetes. In this investigation, the pO2 of capillary blood samples obtained from fingertips was determined in 110 subjects (55 female, 31 with type 1 diabetes mellitus, 69 with type 2 diabetes mellitus, 10 without diabetes; mean age 61 years, from 19 to 78 years); most of them were expected to perform SMBG regularly. The subjects had no acute serious diseases. They participate regularly in SMBG system evaluation studies at the Institute for Diabetes-Technology GmbH at Ulm University, Ulm, Germany. The study protocol was approved by the Ulm University Ethics Committee. Capillary blood samples were obtained by skin puncture, and the pO2 was analyzed on a blood gas analyzer (OPTI™ CCA-TS Analysator, OPTI Medical System Inc., Roswell, GA). Maintenance, handling, and quality control of the blood gas analyzer were performed according to the manufacturer’s labeling. Regular internal and external quality control measurements were performed, as required by German national guidelines. Sample collection and pO2 measurements were performed by trained clinical personnel. The 110 subjects showed a mean pO2 of 71.1 mmHg (standard deviation ± 6.9 mmHg), ranging from 49 to 86 mmHg. Female and male subjects showed similar mean pO2 values (72.5 and 69.8 mmHg, respectively). Ninety-four subjects (~85%) showed pO2 values between >60 and ≤80 mmHg, 6 subjects (~5%) showed pO2 values ≤60 mmHg, and 10 subjects (~9%) showed pO2 values >80 mmHg (Figure 1). Lowest pO2 values (53 and 49 mmHg) were found in two subjects with stable chronic respiratory disease. Figure 1. Relative number of subjects with pO2 values within the respective category. Our results indicate that a broad range of capillary pO2 values occur among a population of healthy people and people with diabetes without acute serious diseases. In a previous study using venous blood samples adjusted to different pO2 levels, we observed remarkable measurement deviations with some GOx systems. Particularly at pO2 ≤45 mmHg, we found considerably overestimated measurements.2 Decreased pO2 values can occur in patients with respiratory diseases, such as chronic obstructive pulmonary disease,3 which is described as being associated with type 2 diabetes.4 At high altitudes or also during long-distance flights, up to ~40% decreased pO2 is reported for arterial blood samples;5 a similar behavior can also be expected for capillary blood samples from the fingertip. In conditions with decreased pO2 values in capillary blood, measurements with oxygen-sensitive systems could be affected, and hypoglycemic events might not be detected adequately. Further investigations should be performed focusing on pO2 variations in capillary blood from fingertips in people with diabetes and the possible impact on glucose measurement results obtained with oxygen-sensitive systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/193229681300700627

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 5

  1. 10.1097/00003246-200105000-00038 · DOI · Paper page
  2. Schmid C, Diabetes Technol Ther
  3. 10.1159/000281879 · DOI
  4. 10.2337/diacare.27.10.2478 · DOI · Paper page
  5. 10.1016/S1579-2129(07)60031-7 · doi:10.1016/s1579-2129(07)60031-7

Cited by

See all 23

Metadata

Authors
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C.
Venue
Journal of Diabetes Science and Technology
Published
2013-11
Volume
7
Issue
6
Pages
1648-1649
ISSN
1932-2968 (ISSN-L)
OpenAlex
W1764588884
Cited by
23
References
0
FWCI
2.12
Type
journal article
Language
en
Open access
green
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Partial Pressure of Oxygen in Capillary Blood Samples from the Fingertip. https://app.cochat.ai/papers/10.1177/193229681300700627
The paper
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2013). Partial Pressure of Oxygen in Capillary Blood Samples from the Fingertip. Journal of Diabetes Science and Technology. https://doi.org/10.1177/193229681300700627

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.