The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing
Abstract
OBJECTIVES: To determine the effects of different oxygen tensions (Po2) on glucose measurements with glucose dehydrogenase (GD)-based and glucose oxidase (GO)-based test strips, to quantitate changes in glucose measurements observed with different Po2 levels, and to discuss the potential risks of oxygen-derived glucose errors in critical care. DESIGN: Venous blood from healthy volunteers was tonometered to create different oxygen tensions simulating patient arterial Po2 levels. Venous blood from diabetic patients was exposed to air to alter oxygen tensions simulating changes in Po2 during sample handling. Whole-blood glucose measurements obtained from these samples with six glucose meters were compared with reference analyzer plasma glucose measurements. Glucose differences were plotted vs. different Po2 levels to identify error trends. Error tolerances were as follows: a) within +/-15 mg/dL of the reference measurement for glucose levels 100 mg/dL. SETTING AND SUBJECTS: Five healthy volunteers in the bench study and 11 diabetic patients in the clinical study. RESULTS: In the bench study, increases in Po2 levels decreased glucose measured with GO-based amperometric test strips, mainly at Po2 levels >100 torr. At nearly constant glucose concentrations, glucose meter systems showed large variations at low (39 torr) vs. high (396 torr) Po2 levels. Glucose measured with GD-based amperometric and GO-based photometric test strips generally were within error tolerances. In the clinical study, 31.6% (Precision PCx), 20.2% (Precision QID), and 23.0% (Glucometer Elite) of glucose measurements with GO-based amperometric test strips, 14.3% (SureStep) of glucose measurements with GO-based photometric test strips, and 4.6% (Accu-Chek Advantage H) and 5.9% (Accu-Chek Comfort Curve) of glucose measurements with GD-based amperometric test strips were out of the error tolerances. CONCLUSIONS: Different oxygen tensions do not significantly affect glucose measured with the GD-based amperometric test strips, and have minimal effect on GO-based photometric test strips. Increases in oxygen tension lowered glucose measured with GO-based amperometric test strips. We recommend that the effects of different oxygen tensions in blood samples on glucose measurements be minimized by using oxygen-independent test strips for point-of-care glucose testing in critically ill and other patients with high or unpredictable blood Po2 levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sell-Monitoring of Blood Glucose
(1996) · Diabetes Care · doi:10.2337/diacare.19.1.s62 · Cited by 89
Cited by
Jacobi, J., Bircher, N., Krinsley, J., Agus, M., Braithwaite, S. S., Deutschman, C., Freire, A. X., Geehan, D., Kohl, B., Nasraway, S. A., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182653269 · Cited by 571
Reliability of point-of-care testing for glucose measurement in critically ill adults*
Kanji, S., Buffie, J., Hutton, B., Bunting, P. S., Singh, A., McDonald, K., Fergusson, D., McIntyre, L. A., & Hebert, P. C. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000189939.10881.60 · Cited by 395
Freckmann, G., Schmid, C., Baumstark, A., Pleus, S., Link, M., & Haug, C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600510 · Cited by 237
The Accuracy of Point-of-Care Glucose Measurements
Rebel, A., Rice, M. A., & Fahy, B. G. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600228 · Cited by 144
Comparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127
Metadata
- Authors
- Tang, Z., Louie, R. F., Lee, J. H., Lee, D. M., Miller, E. E., & Kost, G. J.
- Venue
- Critical Care Medicine
- Published
- 2001-05
- Volume
- 29
- Issue
- 5
- Pages
- 1062-1070
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2041970007
- Cited by
- 188
- References
- 1
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing. https://app.cochat.ai/papers/10.1097/00003246-200105000-00038
- The paper
- Tang, Z., Louie, R. F., Lee, J. H., Lee, D. M., Miller, E. E., & Kost, G. J. (2001). Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing. Critical Care Medicine. https://doi.org/10.1097/00003246-200105000-00038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.