Development of a Highly Stable, Nonaqueous Glucagon Formulation for Delivery via Infusion Pump Systems
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Despite a vigorous research effort, to date, the development of systems that achieve glucagon stability in aqueous formulations (without reconstitution) has failed to produce any clinical candidates. We have developed a novel, nonaqueous glucagon formulation based on a biocompatible pharmaceutical solvent, dimethyl sulfoxide, which demonstrates excellent physical and chemical stability at relatively high concentrations and at high temperatures. Methods: This article reports the development of a novel, biocompatible, nonaqueous native human glucagon formulation for potential use in subcutaneous infusion pump systems. Results: Data are presented that demonstrate physical and chemical stability under presumed storage conditions (>2 years at room temperature) as well as “in use” stability and compatibility in an Insulet’s OmniPod® infusion pump. Also presented are results of a skin irritation study in a rabbit model and pharmacokinetics/pharmacodynamics data following pump administration of glucagon in a diabetic swine model. Conclusions: This nonaqueous glucagon formulation is suitable for further clinical development in pump systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes
Castle, J. R., Engle, J. M., Youssef, J. E., Massoud, R. G., Yuen, K. C. J., Kagan, R., & Ward, W. K. (2010) · Diabetes Care · doi:10.2337/dc09-2254 · Cited by 232
Self-citation
Cited by
Blonde, L., Umpierrez, G. E., Reddy, S. S., McGill, J. B., Berga, S. L., Bush, M., Chandrasekaran, S., DeFronzo, R. A., Einhorn, D., Galindo, R. J., et al. (2022) · Endocrine Practice · doi:10.1016/j.eprac.2022.08.002 · Cited by 507
Samson, S. L., Vellanki, P., Blonde, L., Christofides, E. A., Galindo, R. J., Hirsch, I. B., Isaacs, S. D., Izuora, K. E., Low Wang, C. C., Twining, C. L., et al. (2023) · Endocrine Practice · doi:10.1016/j.eprac.2023.02.001 · Cited by 375
Hövelmann, U., Bysted, B. V., Mouritzen, U., Macchi, F., Lamers, D., Kronshage, B., Møller, D. V., & Heise, T. (2018) · Diabetes Care · doi:10.2337/dc17-1402 · Cited by 115
Gingras, V., Taleb, N., Roy‐Fleming, A., Legault, L., & Rabasa‐Lhoret, R. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13052 · Cited by 113
“Research efforts are advancing for that matter, with new glucagon formulations and analogs being under development or testing in clinical settings.(102,103) Conversely, glucagon exerts diverse effects on many organs and systems, raising questions about its potential additional benefits (eg, reducing satiety) but also…”
Novel preparations of glucagon for the prevention and treatment of hypoglycemia
Hawkes, C. P., De Leon, D. D., & Rickels, M. R. (2019) · Current Diabetes Reports · doi:10.1007/s11892-019-1216-4 · Cited by 46
Hövelmann, U., Olsen, M. B., Mouritzen, U., Lamers, D., Kronshage, B., & Heise, T. (2019) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13562 · Cited by 28
Christiansen, M. P., Cummins, M., Prestrelski, S., Close, N. C., Nguyen, A., & Junaidi, K. (2021) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2021-002137 · Cited by 22
Self-citation
Metadata
- Authors
- Newswanger, B., Ammons, S., Phadnis, N., Ward, W. K., Castle, J., Campbell, R. W., & Prestrelski, S. J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2014-12-29
- Volume
- 9
- Issue
- 1
- Pages
- 24-33
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2158756137
- Cited by
- 51
- References
- 1
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.