Clinical Results of an Automated Artificial Pancreas Using Technosphere Inhaled Insulin to Mimic First-Phase Insulin Secretion
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objective: The purpose of this study was to investigate whether or not adding a fixed preprandial dose of inhaled insulin to a fully automated closed loop artificial pancreas would improve the postprandial glucose control without adding an increased risk of hypoglycemia. Research Design and Methods: Nine subjects with T1DM were recruited for the study. The patients were on closed-loop control for 24 hours starting around 4:30 pm. Mixed meals (~50 g CHO) were given at 6:30 pm and 7:00 am the following day. For the treatment group each meal was preceded by the inhalation of one 10 U dose of Technosphere Insulin (TI). Subcutaneous insulin delivery was controlled by a zone model predictive control algorithm (zone-MPC). At 11:00 am, the patient exercised for 30 ± 5 minutes at 50% of predicted heart rate reserve. Results: The use of TI resulted in increasing the median percentage time in range (70-180 mg/dl, BG) during the 5-hour postprandial period by 21.6% (81.6% and 60% in the with/without TI cases, respectively, P = .06) and reducing the median postprandial glucose peak by 33 mg/dl (172 mg/dl and 205 mg/dl in the with and without TI cases, respectively, P = .004). The median percentage time in range 80-140 mg/dl during the entire study period was 67.5% as compared to percentage time in range without the use of TI of 55.2% ( P = .03). Conclusions: Adding preprandial TI (See video supplement) to an automated closed-loop AP system resulted in superior postprandial control as demonstrated by lower postprandial glucose exposure without addition hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative study of insulin secretion and clearance in normal and obese subjects
Polonsky, K. S., Given, B. D., Hirsch, L., Shapiro, E. T., Tillil, H., Beebe, C., Galloway, J. A., Frank, B. H., Karrison, T., & Van Cauter, E. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113338 · Cited by 444
Fully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315
Self-citationNovel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes
Castle, J. R., Engle, J. M., Youssef, J. E., Massoud, R. G., Yuen, K. C. J., Kagan, R., & Ward, W. K. (2010) · Diabetes Care · doi:10.2337/dc09-2254 · Cited by 232
Haidar, A., Legault, L., Dallaire, M., Alkhateeb, A., Coriati, A., Messier, V., Cheng, P., Millette, M., Boulet, B., & Rabasa-Lhoret, R. (2013) · Canadian Medical Association Journal · doi:10.1503/cmaj.121265 · Cited by 167
Cited by
Coming of age: the artificial pancreas for type 1 diabetes
Thabit, H., & Hovorka, R. (2016) · Diabetologia · doi:10.1007/s00125-016-4022-4 · Cited by 223
“Alternative delivery routes to accelerate systemic insulin appearance include inhaled prandial insulin, which has a faster onset and shorter action profile compared with rapid-acting subcutaneous insulin [63] and preprandial administration by a closed-loop system [64], resulting in an increased amount of time spent in…”
BackgroundISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Huyett, L. M., Ly, T. T., Forlenza, G. P., Reuschel-DiVirgilio, S., Messer, L. H., Wadwa, R. P., Gondhalekar, R., Doyle, F. J., Pinsker, J. E., Maahs, D. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0399 · Cited by 64
“22 A significantly elevated insulin resistance in pubertal teenagers presents a challenge to model-based controllers, as the parameters for this population may differ from those modeled for adults with T1D.”
Self-citationEffect of Afrezza on Glucose Dynamics During HCL Treatment
Galderisi, A., Cohen, N., Calhoun, P., Kraemer, K., Breton, M., Weinzimer, S., & Cengiz, E. (2020) · Diabetes Care · doi:10.2337/dc20-0091 · Cited by 32
“More recently, Afrezza inhaled insulin (MannKind Corporation, Valencia, CA) has been shown as a safe option in adults to overcome suboptimal glycemic control related to the delayed absorption of rapidacting SC analogs, namely, mitigating postprandialhyperglycemia(15)andpreventing late hypoglycemia given Afrezza’s fast…”
Background
Metadata
- Authors
- Zisser, H., Dassau, E., Lee, J. J., Harvey, R. A., Bevier, W., & Doyle, F. J.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2015-04-21
- Volume
- 9
- Issue
- 3
- Pages
- 564-572
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2131733246
- Cited by
- 34
- References
- 4
- FWCI
- 5.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Results of an Automated Artificial Pancreas Using Technosphere Inhaled Insulin to Mimic First-Phase Insulin Secretion. https://app.cochat.ai/papers/10.1177/1932296815582061
- The paper
- Zisser, H., Dassau, E., Lee, J. J., Harvey, R. A., Bevier, W., & Doyle, F. J. (2015). Clinical Results of an Automated Artificial Pancreas Using Technosphere Inhaled Insulin to Mimic First-Phase Insulin Secretion. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296815582061
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.