Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trial
Open accessAbstract
BACKGROUND: Most patients with type 1 diabetes do not achieve their glycemic targets. We aimed to assess the efficacy of glucose-responsive insulin and glucagon closed-loop delivery for controlling glucose levels in adults with type 1 diabetes. METHODS: We conducted a randomized crossover trial involving 15 adults with type 1 diabetes, comparing standard insulin-pump therapy with dual-hormone, closed-loop delivery. Patients were admitted twice to a clinical research facility and received, in random order, both treatments. Each 15-hour visit (from 1600 to 0700) included an evening exercise session, followed by a medium-sized meal, a bedtime snack and an overnight stay. During visits that involved closed-loop delivery, basal insulin and glucagon miniboluses were delivered according to recommendations based on glucose sensor readings and a predictive dosing algorithm at 10-minute intervals. During visits involving standard insulin-pump therapy (control visits), patients used conventional treatment. RESULTS: Dual-hormone closed-loop delivery increased the percentage of time for which patients' plasma glucose levels were in the target range (median 70.7% [interquartile range (IQR) 46.1%-88.4%] for closed-loop delivery v. 57.3% [IQR 25.2%-71.8%] for control, p = 0.003) and decreased the percentage of time for which plasma glucose levels were in the low range (bottom of target range [< 4.0 mmol/L], 0.0% [IQR 0.0%-3.0%] for closed-loop delivery v. 10.2% [IQR 0.0%-13.0%] for control, p = 0.01; hypoglycemia threshold [< 3.3 mmol/L], 0.0% [IQR 0.0%-0.0%] for closed-loop delivery v. 2.8% [IQR 0.0%-5.9%] for control, p = 0.006). Eight participants (53%) had at least 1 hypoglycemic event (plasma glucose < 3.0 mmol/L) during standard treatment, compared with just 1 participant (7%) during closed-loop treatment (p = 0.02). INTERPRETATION: Dual-hormone, closed-loop delivery guided by advanced algorithms improved short-term glucose control and reduced the risk of hypoglycemia in a group of 15 adults with type 1 diabetes. TRIAL REGISTRATION: ClinicalTrials.gov, no. NCT01297946.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In bihormonal closed-loop glucose control, glucagon has been used subcutaneously along with insulin for protection against hypoglycemia.
“More recently, in a bihormonal closed-loop glucose control, glucagon has been used subcutaneously along with insulin for protection against hypoglycemia.”
From Pharmacokinetics Modeling of Exogenous Glucagon in Type 1 Diabetes Mellitus Patients (2013) · cites this paper as [6]
In bihormonal closed-loop systems, small doses of glucagon are frequently administered.
“In this context, small doses of glucagon are frequently administered.”
From Pharmacokinetics Modeling of Exogenous Glucagon in Type 1 Diabetes Mellitus Patients (2013) · cites this paper as [6]
Haidar et al.'s randomized crossover trial showed improvement of glucose control against hypoglycemia with nocturnal glucagon plus insulin closed-loop strategy over open-loop insulin infusion.
“the most recent randomized crossover trial by Haidar et al.,6 which also showed improvement of glucose control against hypoglycemia with nocturnal glucagon plus insulin closed-loop strategy over open-loop insulin infusion.”
From Pharmacokinetics Modeling of Exogenous Glucagon in Type 1 Diabetes Mellitus Patients (2013) · cites this paper as [6]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667 · see citing works
Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes
(2005) · New England Journal of Medicine · doi:10.1056/nejmoa052187 · Cited by 5,138 · see citing works
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894 · see citing works
Hypoglycaemia: the limiting factor in the glycaemic management of type I and type II diabetes.
Cryer, P. (2002) · Diabetologia · doi:10.1007/s00125-002-0822-9 · Cited by 794 · see citing works
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746 · see citing works
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403 · see citing works
Closed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342 · see citing works
Fully Integrated Artificial Pancreas in Type 1 Diabetes
Breton, M., Farret, A., Bruttomesso, D., Anderson, S., Magni, L., Patek, S., Dalla Man, C., Place, J., Demartini, S., Del Favero, S., et al. (2012) · Diabetes · doi:10.2337/db11-1445 · Cited by 315 · see citing works
WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
Shichiri, M., Yamasaki, Y., Kawamori, R., Hakui, N., & Abe, H. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92788-x · Cited by 314 · see citing works
MD-Logic Artificial Pancreas System
Atlas, E., Nimri, R., Miller, S., Grunberg, E. A., & Phillip, M. (2010) · Diabetes Care · doi:10.2337/dc09-1830 · Cited by 266 · see citing works
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244 · see citing works
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235 · see citing works
Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes
Castle, J. R., Engle, J. M., Youssef, J. E., Massoud, R. G., Yuen, K. C. J., Kagan, R., & Ward, W. K. (2010) · Diabetes Care · doi:10.2337/dc09-2254 · Cited by 232 · see citing works
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200 · see citing works
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-2081 · Cited by 180 · see citing works
Blood Glucose Control in Type 1 Diabetes With a Bihormonal Bionic Endocrine Pancreas
Russell, S. J., El-Khatib, F. H., Nathan, D. M., Magyar, K. L., Jiang, J., & Damiano, E. R. (2012) · Diabetes Care · doi:10.2337/dc12-0071 · Cited by 176 · see citing works
Response to Nocturnal Alarms Using a Real-Time Glucose Sensor
Buckingham, B. A., Block, J. M., Burdick, J., Kalajian, A., Kollman, C., Choy, M., Wilson, D. M., & Chase, P. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.440 · Cited by 115 · see citing works
Choudhary, P., Geddes, J., Freeman, J. V., Emery, C., Heller, S. R., & Frier, B. M. (2010) · Diabetic Medicine · doi:10.1111/j.1464-5491.2010.03006.x · Cited by 82 · see citing works
Steffes, M. W., Molitch, M. E., Chavers, B. M., et al. (2003) · JAMA · Cited by 64 · see citing works
Stabilized Glucagon Formulation for Bihormonal Pump Use
Steiner, S. S., Li, M., Hauser, R. G., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400606 · Cited by 39 · see citing works
Ward, W. K., Massoud, R. G., Szybala, C., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400604 · Cited by 21 · see citing works
Effectiveness of sensor-augmented insulin-pump therapy in type 1 diabetes
Davis, S., Dailey, G., Buse, J. B., et al. (2020) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/6550-r726 · Cited by 7 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Weisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463 · see citing works
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197 · see citing works
Herrero, P., Georgiou, P., Oliver, N., Reddy, M., Johnston, D., & Toumazou, C. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700416 · Cited by 55 · see citing works
Tagougui, S., Taleb, N., Legault, L., Suppère, C., Messier, V., Boukabous, I., Shohoudi, A., Ladouceur, M., & Rabasa-Lhoret, R. (2020) · Diabetologia · doi:10.1007/s00125-020-05244-y · Cited by 40 · see citing works
Self-citationModeling Glucagon Action in Patients With Type 1 Diabetes
Emami, A., Youssef, J. E., Rabasa-Lhoret, R., Pineau, J., Castle, J. R., & Haidar, A. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2593630 · Cited by 20 · see citing works
Self-citationPharmacokinetics Modeling of Exogenous Glucagon in Type 1 Diabetes Mellitus Patients
Lv, D., Breton, M. D., & Farhy, L. S. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0150 · Cited by 17 · see citing works
- Authors
- Haidar, A., Legault, L., Dallaire, M., Alkhateeb, A., Coriati, A., Messier, V., Cheng, P., Millette, M., Boulet, B., & Rabasa-Lhoret, R.
- Affiliations
- Montreal Children's Hospital (CA)
- Venue
- Canadian Medical Association Journal
- Publisher
- CMA Joule Inc.
- Published
- 2013-01-28
- Volume
- 185
- Issue
- 4
- Pages
- 297-305
- ISSN
- 0820-3946 (ISSN-L)
- 1488-2329
- PMC
- PMC3589308
- OpenAlex
- W2083628344
- Cited by
- 167
- References
- 22
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 3 · 2023: 6 · 2022: 7 · 2021: 10 · 2020: 10 · 2019: 14 · 2018: 17 · 2017: 14 · 2016: 16 · 2015: 22 · 2014: 28 · 2013: 13
- FWCI
- 20.71
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- other-oa
- Locations
- Canadian Medical Association Journal (publishedVersion, other-oa)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Eli Lilly and Company
- AstraZeneca
- Sanofi
- Canadian Diabetes Association
- Diabète Québec
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- type 1 diabetes, artificial pancreas, glucose-responsive insulin, glucagon, glycemic control, hypoglycemia, insulin pump therapy, glucose sensor, adults with type 1 diabetes, bedtime snack, hypoglycemia risk reduction
- MeSH terms
- Adult, Algorithms, Blood Glucose, Decision Support Techniques, Diabetes Mellitus, Type 1, Drug Administration Schedule, Drug Therapy, Combination, Female, Glucagon, Humans, Hypoglycemia, Hypoglycemic Agents, Insulin Infusion Systems, Male, Regression Analysis, Biomarkers, Infusion Pumps, Implantable, Treatment Outcome, Cross-Over Studies, Pancreas, Artificial, Insulin Aspart
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review