Consensus Statement on Inpatient Use of Continuous Glucose Monitoring
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In June 2016, Diabetes Technology Society convened a panel of US experts in inpatient diabetes management to discuss the current and potential role of continuous glucose monitoring (CGM) in the hospital. This discussion combined with a literature review was a follow-up to a meeting, which took place in May 2015. The panel reviewed evidence on use of CGM in 3 potential inpatient scenarios: (1) the intensive care unit (ICU), (2) non-ICU, and (3) transitioning outpatient CGM use into the hospital setting. Panel members agreed that data from limited studies and theoretical considerations suggested that use of CGM in the hospital had the potential to improve patient clinical outcomes, and in particular reduction of hypoglycemia. Panel members discussed barriers to widespread adoption of CGM, which patients would benefit most from use of this technology, and what type of outcome studies are needed to guide use of CGM in the inpatient setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intensive versus Conventional Glucose Control in Critically Ill Patients
(2009) · New England Journal of Medicine · doi:10.1056/nejmoa0810625 · Cited by 5,119
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy
Clarke, W. L., & Kovatchev, B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100510 · Cited by 71 · cited 1×
“Intravascular CGMs carry risks of thrombus formation, catheter occlusion or biofilm, and catheter-related infections.(23,24) Acetaminophen is commonly used in the hospital setting and may cause a CGM to overestimate glucose.”
Background
Cited by
Management of diabetes and hyperglycaemia in the hospital
Pasquel, F. J., Lansang, M. C., Dhatariya, K., & Umpierrez, G. E. (2021) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(20)30381-8 · Cited by 329
Self-citation15. Diabetes Care in the Hospital: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s015 · Cited by 265
Advances in technology for management of type 1 diabetes
Beck, R. W., Bergenstal, R. M., Laffel, L. M., & Pickup, J. C. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31142-0 · Cited by 242
Teo, E., Hassan, N., Tam, W., & Koh, S. (2022) · Diabetologia · doi:10.1007/s00125-021-05648-4 · Cited by 186
Galindo, R. J., Migdal, A. L., Davis, G. M., Urrutia, M. A., Albury, B., Zambrano, C., Vellanki, P., Pasquel, F. J., Fayfman, M., Peng, L., et al. (2020) · Diabetes Care · doi:10.2337/dc19-2073 · Cited by 181
Self-citation
Metadata
- Authors
- Wallia, A., Umpierrez, G. E., Rushakoff, R. J., Klonoff, D. C., Rubin, D. J., Hill Golden, S., Cook, C. B., Thompson, B., & Panel, T. D. C. G. M. I. T. H.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2017-04-21
- Volume
- 11
- Issue
- 5
- Pages
- 1036-1044
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2605937229
- Cited by
- 147
- References
- 3
- FWCI
- 9.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Consensus Statement on Inpatient Use of Continuous Glucose Monitoring. https://app.cochat.ai/papers/10.1177/1932296817706151
- The paper
- Wallia, A., Umpierrez, G. E., Rushakoff, R. J., Klonoff, D. C., Rubin, D. J., Hill Golden, S., Cook, C. B., Thompson, B., & Panel, T. D. C. G. M. I. T. H. (2017). Consensus Statement on Inpatient Use of Continuous Glucose Monitoring. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296817706151
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.