CoChat

Day-to-Day and Within-Day Variability in Glucose-Lowering Effect Between Insulin Degludec and Insulin Glargine (100 U/mL and 300 U/mL): A Comparison Across Studies

Open access
Heise, Tim, Kaplan, Kadriye, Haahr, Hanne L. · 2018 · Journal of Diabetes Science and Technology
Cited by 40

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: Insulin degludec (IDeg) has significantly lower day-to-day and within-day variability compared to insulin glargine (IGlar) 100U/mL (U100) and 300U/mL (U300). Here, we report post hoc assessments to confirm the robustness of these observations while accounting for potential experimental confounders. Methods: Two euglycemic clamp studies in type 1 diabetes patients, comparing IDeg to IGlar-U100 (Study A, parallel design, 54 patients; Study B, crossover, 22 patients) and one study comparing IDeg to IGlar-U300 (Study C, crossover, 57 patients), all dosed at 0.4U/kg, were evaluated. Pharmacodynamic parameters were assessed at steady state from glucose infusion rate (GIR) profiles following three 24-hour euglycemic clamps in Studies A (162 clamps) and C (342 clamps), and one 42-hour clamp in Study B (44 clamps). Results: Pooled data (Studies A and B) showed that IDeg had an even distribution of glucose-lowering effect over the 24-hour dosing interval that was consistent with Study C. IGlar-U100 showed a constant decrease in glucose-lowering effect over 24 hours while IGlar-U300 had a lower effect in the middle of the dosing interval (6-18 hours). Relative within-day variability of IDeg was 40% and 37% lower than IGlar-U100 and -U300, respectively. Exclusion of profiles with low response in Study C (19/342 clamps) did not impact the difference in the distribution of glucose-lowering effect or within-day variability. Day-to-day variability was significantly lower with IDeg compared to IGlar-U100 and -U300 based on smoothed and unsmoothed GIR data. Conclusions: Significantly lower relative within-day and day-to-day variability was confirmed irrespective of experimental considerations for IDeg compared to IGlar-U100 and IGlar-U300.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1932296817731422

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 40

Metadata

Authors
Heise, T., Kaplan, K., & Haahr, H. L.
Venue
Journal of Diabetes Science and Technology
Published
2017-09-26
Volume
12
Issue
2
Pages
356-363
ISSN
1932-2968 (ISSN-L)
OpenAlex
W2758044071
Cited by
40
References
6
FWCI
3.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Day-to-Day and Within-Day Variability in Glucose-Lowering Effect Between Insulin Degludec and Insulin Glargine (100 U/mL and 300 U/mL): A Comparison Across Studies. https://app.cochat.ai/papers/10.1177/1932296817731422
The paper
Heise, T., Kaplan, K., & Haahr, H. L. (2018). Day-to-Day and Within-Day Variability in Glucose-Lowering Effect Between Insulin Degludec and Insulin Glargine (100 U/mL and 300 U/mL): A Comparison Across Studies. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296817731422

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.