The UVA/Padova Type 1 Diabetes Simulator Goes From Single Meal to Single Day
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
Background: A new version of the UVA/Padova Type 1 Diabetes (T1D) Simulator is presented which provides a more realistic testing scenario. The upgrades to the previous simulator, which was accepted by the Food and Drug Administration in 2013, are described. Method: Intraday variability of insulin sensitivity (S I ) has been modeled, based on clinical T1D data, accounting for both intra- and intersubject variability of daily S I . Thus, time-varying distributions of both subject’s basal insulin infusion and insulin-to-carbohydrate ratio were calculated and made available to the user. A model of “dawn” phenomenon based on clinical T1D data has been also included. Moreover, the model of subcutaneous insulin delivery has been updated with a recently developed model of commercially available fast-acting insulin analogs. Models of both intradermal and inhaled insulin pharmacokinetics have been included. Finally, new models of error affecting continuous glucose monitoring and self-monitoring of blood glucose devices have been added. Results: One hundred in silico adults, adolescent, and children have been generated according to the above modifications. The new simulator reproduces the intraday glucose variability observed in clinical data, also describing the nocturnal glucose increase, and the simulated insulin profiles reflect real life data. Conclusions: The new modifications introduced in the T1D simulator allow to extend its domain of validity from “single-meal” to “single-day” scenarios, thus enabling a more realistic framework for in silico testing of advanced diabetes technologies including glucose sensors, new insulin molecules and artificial pancreas.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the simulation environment was extended beyond its initial single-meal realm of application; 73”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [73]
In the citing paper
“The inter-and intra-day insulin sensitivity variability of the FDA-accepted population 73 was retained.”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [73]
In the citing paper
“The FDA-accepted UVA/Padova T1D simulator for SC insulin delivery and sensing 73 has been updated for IP insulin delivery and IP glucose sensing.”
From Developing the UVA/Padova Type 1 Diabetes Simulator: Modeling, Validation, Refinements, and Utility (2023) · cites this paper as [73]
In the citing paper
“On the contrary, the Hovorka model and the UVAPadova model were originally formulated to represent the physiological behaviour of T1DM individuals, and no modification is necessary for the purpose of the present work.”
From A comparison among three maximal mathematical models of the glucose-insulin system (2021) · cites this paper as [24]
In the citing paper
“This model is indeed included in the EGP module of the UVa/Padova T1D simulator [32–34].”
From Modeling the effect of glucagon on endogenous glucose production in healthy individuals under meal-like conditions (2025) · cites this paper as [34]
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Meal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955
Self-citationThe UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791 · cited 2×
“The pulmonary route of administration is described using the model of inhaled insulin pharmacokinetic described in Visentin et al.(34) This model (equations A20, A21) has been identified on 12 T1D subjects, and assumes that a certain fraction of inhaled insulin reaches the alveoli, and then it is rapidly absorbed from…”
MethodSelf-citationIn Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760 · cited 1×
“In particular, in 2008 the US Food and Drug Administration (FDA) accepted the T1D simulator developed by Universities of Virginia (UVA) and Padova as a substitute for preclinical trials for certain insulin treatments, including closed-loop algorithms for artificial pancreas (AP).(2) This dramatically accelerated the A…”
BackgroundSelf-citationDiabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Self-citationEffects of Age and Sex on Postprandial Glucose Metabolism
Basu, R., Dalla Man, C., Campioni, M., Basu, A., Klee, G., Toffolo, G., Cobelli, C., & Rizza, R. A. (2006) · Diabetes · doi:10.2337/db05-1692 · Cited by 334
Self-citationSimulation Environment to Evaluate Closed-Loop Insulin Delivery Systems in Type 1 Diabetes
Wilinska, M. E., Chassin, L. J., Acerini, C. L., Allen, J. M., Dunger, D. B., & Hovorka, R. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400117 · Cited by 244
Kropff, J., Del Favero, S., Place, J., Toffanin, C., Visentin, R., Monaro, M., Messori, M., Di Palma, F., Lanzola, G., Farret, A., et al. (2015) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(15)00335-6 · Cited by 201
Self-citationDavidson, P. C., Hebblewhite, H. R., Steed, R. D., & Bode, B. W. (2008) · Endocrine Practice · doi:10.4158/ep.14.9.1095 · Cited by 167 · cited 1×
“Total daily insulin (TDI) is determined from basal infusion rate and optimal CR, assuming an average diet of 180 g of CHO for adults and adolescents, and 135 g for children; correction factor (CF) is then calculated using the so-called 1700 rule.(39) Following Dalla Man et al,(7) some additional criteria have been con…”
MethodKanderian, S. S., Weinzimer, S., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300508 · Cited by 161 · cited 1×
“The ability to well reproduce diurnal variability is thus of interest, and other research groups have worked on this topic.(4,23-25) We recently demonstrated the ability of the T1D simulator model to describe glucose dynamics in a large dataset of T1D subjects studied for about 24 hours, by describing insulin sensitiv…”
Pinsker, J. E., Lee, J. B., Dassau, E., Seborg, D. E., Bradley, P. K., Gondhalekar, R., Bevier, W. C., Huyett, L., Zisser, H. C., & Doyle, F. J. (2016) · Diabetes Care · doi:10.2337/dc15-2344 · Cited by 151
Research works printed but not linked: 3
- 10.1109/tbme.2013.2272736 · DOI · Paper page
- Schiavon M, 2016, Diabetologia, 59, s268
- Schiavon M, 2017, Diabetes Technol Ther, 19, A118
Cited by
Items 101–200 of 321
Physiological models for artificial pancreas development
VISENTIN, R., Schiavon, M., Basu, R., Basu, A., Man, C. D., & Cobelli, C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815655-1.00015-6 · Cited by 11
Self-citationMain glucose hepatic fluxes in healthy subjects predicted from a phenomenological-based model
Builes-Montaño, C. E., Lema-Pérez, L., Garcia‐Tirado, J., & Álvarez, H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105232 · Cited by 10
Visentin, R., Schiavon, M., Giegerich, C., Klabunde, T., Man, C. D., & Cobelli, C. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513234 · Cited by 9
“The latest version of the simulator [5] incorporates a number of novelties, the most noteworthy represented by a model of diurnal glucose variability, mainly due to the intra-day varations of insulin sensitivity (SI) and the dawn phenomenon, which extended the domain of validity of the simulator from single- to multip…”
BackgroundMethodSelf-citationControlling and powering a fully implantable artificial pancreas refillable by ingestible pills
Ballardini, G., Tamadon, I., Guarnera, D., Al‐Haddad, H., Iacovacci, V., Mariottini, F., Ricciardi, S., Cucini, A., Libera, A. D., Vistoli, F., et al. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340006 · Cited by 9
“The FDA-accepted T1D simulator for subcutaneous insulin delivery and sensing [10] has been updated for ip delivery and sensing and has allowed the design and in silico validation of a time-varying PID controller to guide the closed-loop ip delivery of the IMD, not requiring meal announcement [20].”
BackgroundMethodSelf-citationIdi, E., Manzoni, E., Facchinetti, A., Sparacino, G., & Favero, S. D. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3465893 · Cited by 9
“As for the simulated dataset, it is obtained generating CGM traces with an accurate simulator of T1D patient physiology, the UVa/Padova T1D Simulator [47].”
Degen, I., Brown, K. R., Reeve, H. W. J., & Abdallah, Z. S. (2024) · JMIRx Med · doi:10.2196/44384 · Cited by 9
Castillo, A., Pryor, E. C., Fathi, A. E., Kovatchev, B. P., & Breton, M. D. (2025) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2025.3562032 · Cited by 9
“In order to generate the initial dataset, D o ≈ M , the MPC algorithm is connected to the FDA-approved Type-1 Diabetes simulator developed at the University of Virginia [40], [41].”
Self-citationSchiavon, M., Herzig, D., Hepprich, M., Donath, M. Y., Bally, L., & Man, C. D. (2021) · Frontiers in Endocrinology · doi:10.3389/fendo.2021.611253 · Cited by 9
Self-citationData-Driven Supervised Compression Artifacts Detection on Continuous Glucose Sensors
Idi, E., Manzoni, E., Sparacino, G., & Favero, S. D. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9870884 · Cited by 9
“A dataset of 100 virtual subjects is generated using the Padova/UVa T1D simulator [18], an accurate physiology simulator that was accepted by Food and Drug Administration as a substitute of animal testing prior to clinical trials on humans.”
MethodA novel model-based estimator for real-time prediction of insulin-on-board
Aiello, E. M., Wolkowicz, K. L., Pinsker, J. E., Dassau, E., & Doyle, F. J. (2022) · Chemical Engineering Science · doi:10.1016/j.ces.2022.118321 · Cited by 9
Colmegna, P. H., C., J. L. D., Garcia‐Tirado, J., DeBoer, M. D., & Breton, M. D. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221140401 · Cited by 9
“The first step to exploring potential adaptations is to modify the SC insulin delivery model within the UVA/Padova simulation platform 18 to accurately reproduce PK/PD differences between lispro and URLi.”
MethodSelf-citationTailoring the Padova Type 2 Diabetes Simulator for Treatment Guidance in Target Populations
VISENTIN, R., Schiavon, M., Bonet, J., Riz, M., Wagenhuber, B., & Man, C. D. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3352153 · Cited by 9
“An example of such in silico tools is the UVA/Padova type 1 diabetes (T1D) simulator [2], [3], [4] that has been accepted and widely used as decision support system for testing several diabetes technology treatments, such as artificial pancreas prototypes (e.g., [5], [6], [7]) and, more recently,…”
BackgroundMethodSelf-citationData-Driven Disturbance Estimation and Control With Application to Blood Glucose Regulation
Novara, C., Rabbone, I., & Tinti, D. (2019) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2019.2893569 · Cited by 10
Úbl, M., Koutný, T., Cioppa, A. D., Falco, I. D., Tarantino, E., & Scafuri, U. (2022) · Sensors · doi:10.3390/s22239445 · Cited by 9
“These simulators are approved for a single-day scenario with up to three meals daily [18].”
BackgroundDesign and Validation of an Open-Source Closed-Loop Testbed for Artificial Pancreas SystemsPreprint
Zhou, X., Kouzel, M., Ren, H., & Alemzadeh, H. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2208.06479 · Cited by 9
“Much work has been done in the literature to develop realistic diabetes simulators [40, 50, 64], design advanced control algorithms to maintain glucose concentration at healthy levels [16, 47], and conduct large-scale clinical trials [13, 14, 49].”
BackgroundDalla Libera, A., Toffanin, C., Drecogna, M., Galderisi, A., Pillonetto, G., & Cobelli, C. (2023) · APL Bioengineering · doi:10.1063/5.0145446 · Cited by 8
Self-citationSchiavon, M., Galderisi, A., Basu, A., Kudva, Y. C., Cengiz, E., & Dalla Man, C. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0397 · Cited by 8
“13 In particular, we used the virtual adult population of the UVa/Padova T1D Simulator 17 to perform an in silico scenario, consisting of a 70 g CHO meal administered three times: in the first experiment, the meal insulin bolus was calculated based on patient-specific CR; whereas in the second and…”
InfluentialSelf-citationAbuin, P., Ferramosca, A., Toffanin, C., Magni, L., & González, A. H. (2022) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2022.09.023 · Cited by 8
Recovering Implicit Physics Model Under Real-World Constraints
Banerjee, A., & Gupta, S. K. S. (2024) · Frontiers in artificial intelligence and applications · doi:10.3233/faia240556 · Cited by 8
“For AID we create simulation benchmark using the Food and Drug Administration (FDA) approved UVA/PADOVA Type 1 Diabetes (T1D) simulator [36].”
MethodFalco, I. D., Cioppa, A. D., Marcelli, A., Scafuri, U., Stellaccio, L., & Tarantino, E. (2021) · Genetic and Evolutionary Computation Conference Companion (GECCO Companion) · doi:10.1145/3449726.3463143 · Cited by 8
“The physiological models are related to the development of glucoseinsulin compartmental models each capable of emulating different human physiological behavior by describing the glucose dynamics during the insulin treatment [16, 28, 37].”
BackgroundTime to Moderate and Severe Hyperglycemia and Ketonemia Following an Insulin Pump Occlusion
Klonoff, D. C., Ayers, A. T., Ho, C. N., Fabris, C., Villa-Tamayo, M. F., Allen, E., Cengiz, E., Ekhlaspour, L., Wong, J. C., Heineman, L., et al. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241280386 · Cited by 7
Idi, E., Prendin, F., Facchinetti, A., Sparacino, G., & Favero, S. D. (2023) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn58485.2023.10331579 · Cited by 7
“A synthetic dataset of 100 virtual subjects is generated using the Padova/UVa T1D Simulator [9], an accurate T1D physiology simulator approved by Food and Drug Administration (FDA) as a method for in silico testing before clinical trials.”
MethodPavan, J., Noaro, G., Facchinetti, A., Salvagnin, D., Sparacino, G., & Favero, S. D. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108179 · Cited by 7
Modeling sex-specific whole-body metabolic responses to feeding and fasting
Abo, S. M. C., & Layton, A. T. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109024 · Cited by 7
Nonlinear Machine Learning Models for Insulin Bolus Estimation in Type 1 Diabetes Therapy
Noaro, G., Cappon, G., Sparacino, G., Favero, S. D., & Facchinetti, A. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176021 · Cited by 7
“For this reason, a natural further extension will be to generate a more realistic multi-meal scenario [12], by adding error sources, such as errors in patient behavior [13], carbohydrates miscalculations [14], sensor readings [15] [16].”
BackgroundRodríguez-Sarmiento, D. L., Jutinico, A. L., & Vargas, F. M. L. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106166 · Cited by 7
Autoencoder-Based Detection of Insulin Pump Faults in Type 1 Diabetes Treatment
Idi, E., Prendin, F., Sparacino, G., & Favero, S. D. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3518233 · Cited by 7
“The pipeline proposed in this work is assessed using one of the latest versions of the UVA/Padova T1D Simulator [21], an FDA-accepted simulator of T1D physiology, developed for in silico testing prior to clinical trials.”
Method to generate a large cohort in-silico for type 1 diabetes
Orozco-López, O., Rodríguez-Herrero, A., Castaneda, C. E., García-Sáez, G., & Hernando, M. E. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105523 · Cited by 7
Automated Adaptation of Insulin Treatment in Type 1 Diabetes
Fabris, C., Gautier, T., & Breton, M. D. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630191 · Cited by 7
“Here, we present results obtained by testing the optimization algorithm in an FDAaccepted simulation environment known as the University of Virginia/Padova T1D Simulator [21]-[23].”
MethodSelf-citationA software interface for in silico testing of type 2 diabetes treatments
VISENTIN, R., Cobelli, C., & Man, C. D. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106973 · Cited by 7
Self-citationPersonalized LSTM-based alarm systems for hypoglycemia prevention
Toffanin, C., Iacono, F. D., & Magni, L. (2023) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med59994.2023.10185789 · Cited by 7
“Three different datasets are generated through the UVA/ Padova simulator [16]: a training dataset ( tr-dt ), used to train the network; a validation one ( v-dt ), for the hyperparameters tuning and a testing dataset ( ts-dt ), to assess the LSTM performance.”
MethodVISENTIN, R., Schiavon, M., & Man, C. D. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175271 · Cited by 8
“An example is the type 1 diabetes (T1D) simulator [2] that has been extensively used for testing artificial pancreas prototypes, novel insulin formulations and glucose monitoring systems, e.”
MethodSelf-citationModeling Intraperitoneal Insulin Absorption in Patients with Type 1 Diabetes
Schiavon, M., Cobelli, C., & Dalla Man, C. (2021) · Metabolites · doi:10.3390/metabo11090600 · Cited by 6
“Specifically, for all the models, a priori information on whole-body insulin kinetics parameters VI, m1, CL and HEb has been used to improve their numerical identifiability [15].”
BackgroundMethodSelf-citationMoscoso-Vásquez, M., Fabris, C., & Breton, M. D. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231206798 · Cited by 6
“…in terms of clinically relevant metrics, we leverage the Food and Drug Administration–accepted University of Virginia (UVA)/Padova T1D simulator 29 to (1) obtain estimates of IS for the adult in silico population under different conditions and (2) evaluate the impact of IS-based controller…”
MethodSelf-citationPersonalized Model Identification for Glucose Dynamics From Clinical Data With Incomplete Inputs
Özaslan, B., Aiello, E. M., Fushimi, E., Doyle, F. J., & Dassau, E. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3530711 · Cited by 6
“The nonlinear glucose response to low glucose that is not captured in the linearized SOGMM and unmodeled dynamics of counter-regulation [28] are likely additional factors contributing to the poor model prediction performance observed for this participant.”
Detection of Unknown-Unknowns in Human-in-Loop Human-in-Plant Safety Critical Systems
Maity, A., Banerjee, A., & Gupta, S. K. S. (2025) · IEEE Transactions on Artificial Intelligence · doi:10.1109/tai.2025.3550913 · Cited by 6
“The model M ( θ ) for the AP was the T1D simulator, which is an FDA-approved simulator and widely used for evaluating AP controllers [32].”
Dynamic of Glucose Homeostasis in Virtual Patients: A Comparison between Different Behaviors
Alonso‐Bastida, A., Adam‐Medina, M., Posada, R., Salazar-Piña, D. A., Osorio-Gordillo, G. L., & Valdés, L. G. V. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19020716 · Cited by 6
“[16] on the other hand generates VP with T1DM and Visentin et al.”
BackgroundModel Personalization in an Advanced Automated Insulin Delivery System: An In-Silico Exploration
Villa-Tamayo, M. F., C., J. L. D., Moscoso-Vásquez, M., Castillo, A., Garcia‐Tirado, J., Colmegna, P. H., & Breton, M. D. (2022) · International Conference on Systems and Control (ICSC) · doi:10.1109/icsc57768.2022.9993926 · Cited by 6
“To assess how this daily personalization can improve closed-loop performance in terms of clinically relevant metrics, we conduct two-week simulation experiments with and without model personalization using the 100 adult cohort of the Food and Drug Administration (FDA)-accepted UVA/Padova Type 1 Diabetes (T1D) Simulato…”
MethodSelf-citationColmegna, P. H., Diaz, J. L., Garcia‐Tirado, J., & Breton, M. D. (2022) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc51059.2022.9993157 · Cited by 6
“In Silico Results In order to evaluate robustness and efficacy of the proposed FCL+ strategy, one-day simulations are performed with all 100 in silico adults of the FDA-accepted UVA/Padova T1D Simulator under various meal conditions.”
MethodSelf-citationManzoni, E., Rampazzo, M., Facchinetti, A., Sparacino, G., & Favero, S. D. (2023) · Control Engineering Practice · doi:10.1016/j.conengprac.2023.105673 · Cited by 6
Chen, Z., Nie, Z., Li, J., Wu, Y., & Zhou, H. (2023) · IEEE International Conference on Cloud Computing and Intelligence Systems (CCIS) · doi:10.1109/ccis59572.2023.10263038 · Cited by 6
“In this study, we conducted experiments using simulated data generated by the UVA/Padova simulator[10], which simulates the blood glucose variations of ten adult T1D patients.”
MethodPersonalized Constrained MPC for glucose regulation
Toffanin, C., & Magni, L. (2023) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2023.10.272 · Cited by 6
Maity, A., Banerjee, A., & Gupta, S. K. S. (2023) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/ieeeconf59524.2023.10476736 · Cited by 6
“The model M ( θ ) for the AP was the T1D simulator, which is an FDA-approved simulator and widely used for evaluating AP controllers [16].”
MethodProcopio, A., Rania, M., Zaffino, P., Cortese, N., Giofrè, F., Arturi, F., Segura‐Garcìa, C., & Cosentino, C. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108477 · Cited by 6
Ganji, M., Fathi, A. E., Fabris, C., Lv, D., Kovatchev, B. P., & Breton, M. D. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.109714 · Cited by 7
“The UVA/Padova T1D simulator, a simulation platform accepted by the U.S. Food and Drug Administration (FDA), has been utilized for years as a substitute for animal pre-clinical trials, opening new possibilities for designing personalized treatments[20], [21], [22], [23], [24], [25].”
MethodSelf-citationA Hybrid Automata Approach for Monitoring the Patient in the Loop in Artificial Pancreas Systems
Beneyto, A., Puig, V., Bequette, B. W., & Vehí, J. (2021) · Sensors · doi:10.3390/s21217117 · Cited by 6
“Since then, many other models have appeared such as the more complex Food and Drug Administration (FDA) accepted UVA/Padova T1D Simulator [39].”
BackgroundEvaluating Deep Q-Learning Techniques for Controlling Type 1 Diabetes
Hjerde, S. T. N. (2020) · NVA (Nasjonalt vitenarkiv) · Cited by 6
Schiavon, M., Acciaroli, G., Vettoretti, M., Giaretta, A., & Visentin, R. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512257 · Cited by 5
“B) and (iii) to validate the incorporation of such a model into the UVA/Padova T1D Simulator [9] against real data [13] (Section II.”
BackgroundMethodInfluentialSelf-citationManzoni, E., Idi, E., Camerlingo, N., Facchinetti, A., Sparacino, G., & Favero, S. D. (2025) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2025.3536805 · Cited by 5
“To get the best of both options, our study incorporates both in-silico datasets (UVa/Padova Type 1 Diabetes simulator [27]) and a real-world dataset from T1D adults using Dexcom G6 CGM sensors (Dexcom, Inc., San Diego, CA) [28].”
Generalized reinforcement learning control algorithm for fully automated insulin delivery system
Rachim, V. P., Yoo, J., Lee, J., Lee, Y., & Park, S. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.126909 · Cited by 5
Brunasso, A., Man, C. D., Poli, S., Prompers, J. J., Herzig, D., Kreis, R., Bally, L., & Schiavon, M. (2025) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00511.2024 · Cited by 5
Self-citationKalita, D., Sharma, H., & Mirza, K. B. (2025) · Expert Systems with Applications · doi:10.1016/j.eswa.2025.128833 · Cited by 5
Metabolic Models, in Silico Trials, and Algorithms
Çınar, A., Basu, A., Bequette, B. W., Breton, M. D., Buckingham, B. A., Cengiz, E., Cobelli, C., Dassau, E., Doyle, F. J., Fabris, C., et al. (2025) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2025.18800.ac · Cited by 5
“30 A milestone achievement was the development of the University of Virginia-University of Padova (UVa-Padova) T1D Simulator, 31 – 34 accepted by the U.S. Food and Drug Administration (FDA) in 2008, that was underpinned by extensive dynamic pro fi ling of carbohydrate metabolism in over 200 adults…”
Self-citationGlucose Level Control in Type 1 Diabetes Patients
Pintea, P. A., & Mihaly, V. M. (2023) · International Conference on System Theory, Control and Computing (ICSTCC) · doi:10.1109/icstcc59206.2023.10308454 · Cited by 5
“The results will refer to a period of 24 hours [11] - [14].”
BackgroundYoo, J., Rachim, V. P., Jung, S., & Park, S. (2024) · IEEE Access · doi:10.1109/access.2024.3518832 · Cited by 5
“Intra-day SI variation was also introduced, including the dawn phenomenon and insulin sensitivity variations at each meal [28].”
Accounting for Hypoglycemia Treatments in Continuous Glucose Metrics
Pryor, E. C., Fathi, A. E., & Breton, M. D. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968251329952 · Cited by 5
“We use the UVA/Padova Simulator 29 with a virtual population of 100 subjects to simulate the effect of HTs.”
Self-citationEnsuring Stability and Fidelity of Recursively Identified Control-Relevant Models
Hajizadeh, I., Rashid, M. M., & Çınar, A. (2018) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2018.09.075 · Cited by 5
Closed-loop MPC-based artificial pancreas: Handling circadian variability of insulin sensitivity
Abuin, P., Sereno, J. E., Ferramosca, A., & González, A. H. (2020) · Argentine Conference on Automatic Control (AADECA) · doi:10.23919/aadeca49780.2020.9301636 · Cited by 5
“[6] who using minimal model for SI estimation, detected 7 classes of SI patterns.”
MethodInfluentialBanerjee, A., Maity, A., Lamrani, I., & Gupta, S. K. S. (2025) · ACM Journal on Emerging Technologies in Computing Systems · doi:10.1145/3736766 · Cited by 5
Rahmanian, F., Asemani, M. H., Dehghani, M., & Mobayen, S. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103088 · Cited by 5
Gluclas: A software for computer-aided modulation of glucose infusion in glucose clamp experiments
Pavan, J., Man, C. D., Herzig, D., Bally, L., & Favero, S. D. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107104 · Cited by 5
Úbl, M., & Koutný, T. (2022) · Procedia Computer Science · doi:10.1016/j.procs.2022.10.127 · Cited by 5
Glucose-ML: A collection of longitudinal diabetes datasets for development of robust AI solutionsPreprint
Prioleau, T., Lu, B., & Cui, Y. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2507.14077 · Cited by 5
“Conversely, the UVA/Pavoda Type 1 Diabetes simulator has been released in three versions (S2008 [56], S2013 [67], and S2017 [108]) each of which includes virtual T1D subjects (adults, adolescents, and children).”
DCRNet: Hybrid Deep Learning Architecture for Forecasting of Blood Glucose
Lad, K., & Joshi, M. (2025) · Journal of Electronics Electromedical Engineering and Medical Informatics · doi:10.35882/jeeemi.v8i1.1245 · Cited by 4
Maqsood, S., Sarwar, M. A., Belousovienė, E., & Maskeliūnas, R. (2026) · IEEE Access · doi:10.1109/access.2026.3672553 · Cited by 4
“The Bergman minimal model provided a foundation for quantifying insulin sensitivity [24], while compartmental models enabled model predictive control (MPC) strategies such as Hovorka for Type 1 diabetes [25] and validated in silico within the UVA/Padova simulator ecosystem [26], [27], [28].”
Personalized hybrid artificial pancreas using unidirectional sliding-modes control algorithm
Orozco-López, O., Castaneda, C. E., García-Sáez, G., Hernando, M. E., & Rodríguez-Herrero, A. (2022) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2022.10.003 · Cited by 4
HypoTreat: Reducing Hypoglycemia in Artificial Pancreas Simulation
Chlumsky-Harttmann, M., Ayad, A., & Schmeink, A. (2024) · IEEE Conference on Evolving and Adaptive Intelligent Systems (EAIS) · doi:10.1109/eais58494.2024.10569096 · Cited by 4
Virtual therapy using Type 1 Diabetes Direct Simulator
Nowicki, T. J. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1736/1/012031 · Cited by 4
Grammatical Evolution-Based Approach for Extracting Interpretable Glucose-Dynamics Models
Falco, I. D., Cioppa, A. D., Koutný, T., Scafuri, U., Tarantino, E., & Úbl, M. (2021) · IEEE Symposium on Computers and Communications (ISCC) · doi:10.1109/iscc53001.2021.9631483 · Cited by 4
Noaro, G., Cappon, G., Sparacino, G., & Facchinetti, A. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630843 · Cited by 4
“Further development of this work will include the assessment of the methodology in a multi-meal scenario [17], with the addition of variability and multiple sources of error, such as CGM measurement error [18], [19] and CHO counting error [20].”
MethodScharbarg, E., Greck, J., Carpentier, É. L., Chaillous, L., & Moog, C. H. (2022) · Scientific Reports · doi:10.1038/s41598-022-11772-x · Cited by 4
Improving Diabetes Conventional Therapy via Machine Learning Modeling
Aiello, E. M., Wu, Z., Christofides, P. D., Toffanin, C., Cobelli, C., & Magni, L. (2019) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2019.8815347 · Cited by 4
“In silico data are used for model identification and testing with the 2018 version of the FDA-accepted UVA/PADOVA simulator [7], which includes intra- and inter-day variability of insulin sensitivity, dawn phenomenon effect, and different distributions of Carbohydrate-to-insulin Ratio (CR) at different day time [8].”
MethodSelf-citationGlucose-Insulin Dynamical Model for Type 2 Diabetic Patients.Preprint
Ahdab, M. A., Leth, J., Knudsen, T., & Clausen, H. G. (2020) · arXiv (Cornell University) · Cited by 4
Maity, A., Banerjee, A., & Gupta, S. K. S. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2309.02603 · Cited by 4
“The model M ( θ ) for the AP was the T1D simulator, which is an FDA-approved simulator and widely used for evaluating AP controllers [16].”
MethodA Real-Time Digital Twin for Type 1 Diabetes Using Simulation-Based Inference
Hoang, T.-D., Bissoto, A., Naik, V. V., Flühmann, T., Shlychkov, A., Garcia‐Tirado, J., & Koch, L. M. (2025) · Lecture notes in computer science · doi:10.1007/978-3-032-07694-6_4 · Cited by 3
Sirael: Virtual Metabolic Machine
Koutný, T. (2024) · Biomedical Materials & Devices · doi:10.1007/s44174-024-00199-9 · Cited by 3
“Reference [9] presents the advancement from a single-meal scenario to a single-day scenario.”
GLP-1 Receptor Agonists Models for Type 1 Diabetes: A Narrative Review
Furió-Novejarque, C., Díez, J.-L., & Bondía, J. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241285925 · Cited by 3
“However, the most widely used simulators for T1D 18-20 do not incorporate the effects of adjunctive therapies such as GLP-1 RA.”
Aligning Insulin Therapy with Individual Preferences: A Multi-objective Decision Support System
Pryor, E. C., Villa-Tamayo, M. F., Pavan, J., & Breton, M. D. (2025) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.06.029 · Cited by 3
Self-citationPOGO: A Method for individualization of Automated Insulin Delivery Systems
Pryor, E. C., Moscoso-Vásquez, M., & Breton, M. D. (2025) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.06.008 · Cited by 3
Self-citationSiket, M., Toth, R., Szász, L., Novák, K., Eigner, G., & Kovács, L. (2023) · IEEE World Symposium on Applied Machine Intelligence and Informatics (SAMI) · doi:10.1109/sami58000.2023.10044485 · Cited by 3
Toffanin, C., & Magni, L. (2023) · Control Engineering Practice · doi:10.1016/j.conengprac.2023.105578 · Cited by 3
Витольдович, П. К., Chuprakov, D. A., Strukova, E. I., & Litinskaia, E. L. (2023) · Ural Symposium on Biomedical Engineering, Radioelectronics and Information Technology (USBEREIT) · doi:10.1109/usbereit58508.2023.10158815 · Cited by 3
“Glucagon secretion is mathematically described in [11].”
BackgroundA Deep-Learning Based Algorithm for the Management of Hyperglycemia in Type 1 Diabetes Therapy
Pellizzari, E., Prendin, F., Cappon, G., Sparacino, G., & Facchinetti, A. (2023) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn58485.2023.10330994 · Cited by 3
“This duration is obtained from a white-box model of patients’ personal glucose-insulin dynamics based on the comprehensive physiological model of the UVa/Padova T1D Simulator [11].”
MethodIdi, E., Facchinetti, A., Sparacino, G., & Favero, S. D. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241248402 · Cited by 3
“…the simulator includes the intra-day insulin sensitivity fluctuation, as modeled in Visentin et al, 18 and dawn effect, as modeled in Visentin et al 17 and Mallad et al, 19 possibly causing unexpected glucose increases and thus posing a challenge for fault detection algorithms monitoring insulin…”
InfluentialVirtual diabetic patient with physical activity dynamics
Islam, M. J., & Hoque, A. S. M. L. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106485 · Cited by 3
Schiavon, M., Man, C. D., & Cobelli, C. (2019) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.2019.8814915 · Cited by 3
“To assess algorithm’s robustness, several scenarios, including suboptimal CR and/or 978-1-5386-7926-5/$31.00 ©2019 AACC 4124 basal insulin infusion, were implemented in the single-day University of Virginia (UVA)/Padova T1D Simulator [16], which incorporates a model for intra-day variability of insulin sensitivity and…”
BackgroundMethodSelf-citationThe Safety Challenges of Deep Learning in Real-World Type 1 Diabetes ManagementPreprint
Emerson, H., McConville, R., & Guy, M. (2023) · arXiv (Cornell University) · doi:10.48550/arxiv.2310.14743 · Cited by 3
“This model describes glucose-insulin dynamics in people with T1D and can replicate intra-day insulin sensitivity variation and model the effect of different administration routes on insulin activity [19].”
BackgroundSafety Generalization Under Distribution Shift in Safe Reinforcement Learning: A Diabetes TestbedPreprint
Kwon, M., Lamp, J., & Feng, L. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2601.21094 · Cited by 3
“Following the UVA/Padova logic, gastric emptying is governed by a nonlinear rate k gut ( q sto ; D bar ) , which depends on the total ingested glucose D bar to account for stacking effects from prior meals (Visentin et al., 2018).”
InfluentialKimmig, F. (2019) · theses.fr (ABES) · doi:10.70675/036592a9zb3d7z41fcza827zb499122a6fae · Cited by 3
Villa-Tamayo, M. F., Colmegna, P. H., & Breton, M. D. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231212205 · Cited by 2
“24 Rebound hypoglycemia events and glucose outcome metrics are reported for two different simulation scenarios: one including unannounced meals and another including an over-sized manual bolus.”
BackgroundSelf-citationLongo, I., D’Antoni, F., Petrosino, L., Piemonte, V., Merone, M., & Pecchia, L. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-61625-9_34 · Cited by 2
Mathematical Modeling in Diabetes Care and Innovation
Maamar, M. H. (2025) · Industrial and applied mathematics · doi:10.1007/978-981-96-1925-2_4 · Cited by 2
Villa-Tamayo, M. F., Pavan, J., & Breton, M. D. (2025) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2025.06.022 · Cited by 2
Self-citationNew physics-LSTM hybrid models for control-oriented glucose prediction in Type 1 Diabetes*
Mongini, P. A., Drecogna, M., & Toffanin, C. (2025) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc63710.2025.11107934 · Cited by 2
“The proposed work has been developed using the UVA/Padova simulator [20], [21], a metabolic simulator approved by the Food and Drugs Administration (FDA) as an alternative to animal trials in the pre-clinical testing of control strategies for diabetes management.”
Reducing exercise-related hypoglycemia in automated insulin delivery with reinforcement learning
Zimmermann, D., & Kaltenbach, H. (2025) · IFAC Journal of Systems and Control · doi:10.1016/j.ifacsc.2025.100337 · Cited by 2
Biester, T., Reschke, F., Danne, T., Julien, M., Lutsar, I., Cheng, K. Y., Cavaller-Bellaubi, M., Katz, M., Niemöller, E., Renard, É., et al. (2025) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2025-0327 · Cited by 2
Validating medical digital twins for clinical decision support: beyond predictive accuracy
Vallée, A. (2026) · JAMIA Open · doi:10.1093/jamiaopen/ooag160 · Cited by 2
Modeling ovarian hormone effects on glucose–insulin control in type 1 diabetes
ALBALADEJO, N., Furió-Novejarque, C., Nattero‐Chávez, L., Bondía, J., & Díez, J.-L. (2026) · Bioengineering & Translational Medicine · doi:10.1002/btm2.70168 · Cited by 2
“Later extensions, such as Kovatchev 44 and Visentin et al., 48 validated these models in silico and clinically to support closed-loop control algorithms.”
Lv, D., Garcia‐Tirado, J., & Fabris, C. (2018) · OBM Transplantation · doi:10.21926/obm.transplant.1803019 · Cited by 2
Self-citationMustaffa, M. S., Sapiee, N. H., Som, A. M., & Ali, S. A. (2023) · IEEE Control and System Graduate Research Colloquium (ICSGRC) · doi:10.1109/icsgrc57744.2023.10215439 · Cited by 2
“Therefore, this constant CHO also keeps in for a Hovorka model [6] [7].”
Background
Metadata
- Authors
- Visentin, R., Campos-Náñez, E., Schiavon, M., Lv, D., Vettoretti, M., Breton, M., Kovatchev, B. P., Dalla Man, C., & Cobelli, C.
- Affiliations
- University of Padua (IT)
- University of Virginia (US)
- Department of Information Engineering, University of Padova, Padova, Italy
- ORCID
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2018-02-16
- Volume
- 12
- Issue
- 2
- Pages
- 273-281
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC5851236
- OpenAlex
- W2790915589
- Semantic Scholar
- 55662e5d64d6d59abe32634a0272c0c17b04c13a
- Cited by
- 280
- References
- 39
- Citations by year
- 2026: 21 · 2025: 43 · 2024: 39 · 2023: 45 · 2022: 36 · 2021: 34 · 2020: 32 · 2019: 22 · 2018: 8
- FWCI
- 19.08
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- type 1 diabetes, in silico modeling, insulin-to-carbohydrate ratio, dawn phenomenon, subcutaneous insulin administration, inhaled insulin, self-monitoring of blood glucose, artificial pancreas, glucose sensor
- MeSH terms
- Adolescent, Adult, Blood Glucose, Child, Computer Simulation, Diabetes Mellitus, Type 1, Humans, Insulin Resistance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.