Using Cluster Analysis to Understand Clinician Readiness to Promote Continuous Glucose Monitoring Adoption
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Background: Many people with type 1 diabetes (T1D) report barriers to using continuous glucose monitoring (CGM). Diabetes care providers may have their own barriers to promoting CGM uptake. The goal of this study was to develop clinician “personas” with regard to readiness to promote CGM uptake. Methods: Diabetes care providers who treat people with T1D (N = 209) completed a survey on perceived patient barriers to device uptake, technology attitudes, and characteristics and barriers specific to their clinical practice. K-means cluster analyses grouped the sample by CGM barriers and attitudes. ANOVAs and chi-square tests assessed group differences on provider and patient characteristics. The authors assigned descriptive names for each persona. Results: Analyses yielded three clinician personas regarding readiness to promote CGM uptake. Ready clinicians (20% of sample; 24% physicians, 38% certified diabetes educators/CDEs) had positive technology attitudes, had clinic time to work with patients using CGM, and found it easy to keep up with technology advances. In comparison, Cautious clinicians (41% of sample; 17% physicians, 53% CDEs) perceived that their patients had many barriers to adopting CGM and had less time than the Ready group to work with patients using CGM data. Not Yet Ready clinicians (40% of sample; 9% physicians; 79% CDEs) had negative technology attitudes and the least clinic time to work with CGM data. They found it difficult to keep up with technology advances. Conclusion: Some diabetes clinicians may benefit from tailored interventions and additional time and resources to empower them to help facilitate increased uptake of CGM technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Implicit bias in healthcare professionals: a systematic review
FitzGerald, C., & Hurst, S. (2017) · BMC Medical Ethics · doi:10.1186/s12910-017-0179-8 · Cited by 2,556
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
The use and reporting of cluster analysis in health psychology: A review
Clatworthy, J., Buick, D., Hankins, M., Weinman, J., & Horne, R. (2005) · British Journal of Health Psychology · doi:10.1348/135910705x25697 · Cited by 598
Sabin, J. A., & Greenwald, A. G. (2012) · American Journal of Public Health · doi:10.2105/ajph.2011.300621 · Cited by 525
A systematic review of the impact of physician implicit racial bias on clinical decision making
Dehon, E., Weiss, N., Jones, J., Faulconer, W., Hinton, E., & Sterling, S. (2017) · Academic Emergency Medicine · doi:10.1111/acem.13214 · Cited by 404
Polonsky, W. H., Hessler, D., Ruedy, K. J., & Beck, R. W. (2017) · Diabetes Care · doi:10.2337/dc17-0133 · Cited by 346
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Cited by
Barriers to continuous glucose monitoring in people with type 1 diabetes: clinician perspectives
Lanning, M. S., Tanenbaum, M. L., Wong, J. J., & Hood, K. K. (2020) · Diabetes Spectrum · doi:10.2337/ds19-0039 · Cited by 40
Benefits and limitations of continuous glucose monitoring in type 1 diabetes
Stone, J. Y., & Bailey, T. S. (2020) · Expert Review of Endocrinology & Metabolism · doi:10.1080/17446651.2020.1706482 · Cited by 30
“Other times this can be due to clinicians’ perceptions of their patients’ barriers to adopting CGM [59], which is not always inappropriate, but should be verified in”
BackgroundMacLeod, J., Scher, L., Greenwood, D., Isaacs, D., Albanese-O’Neill, A., O’Neill, M. S., Golden, L., & Scalzo, P. (2021) · ADCES in Practice · doi:10.1177/2633559x211032227 · Cited by 16
Albanese-O’Neill, A. (2023) · Diabetes Spectrum · doi:10.2337/dsi23-0006 · Cited by 9
Metadata
- Authors
- Tanenbaum, M. L., Adams, R. N., Lanning, M. S., Hanes, S. J., Agustin, B. I., Naranjo, D., & Hood, K. K.
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2018-07-11
- Volume
- 12
- Issue
- 6
- Pages
- 1108-1115
- ISSN
- 1932-2968 (ISSN-L)
- OpenAlex
- W2865939819
- Cited by
- 50
- References
- 13
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using Cluster Analysis to Understand Clinician Readiness to Promote Continuous Glucose Monitoring Adoption. https://app.cochat.ai/papers/10.1177/1932296818786486
- The paper
- Tanenbaum, M. L., Adams, R. N., Lanning, M. S., Hanes, S. J., Agustin, B. I., Naranjo, D., & Hood, K. K. (2018). Using Cluster Analysis to Understand Clinician Readiness to Promote Continuous Glucose Monitoring Adoption. Journal of Diabetes Science and Technology. https://doi.org/10.1177/1932296818786486
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.