Evaluation of Point of Care Analyzer for Hemoglobin A1c
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The systematic review and meta-analysis included 11 studies involving 1,593 participants and 3,285 paired HbA1c measurements comparing POC devices with reference HPLC-based laboratory methods.
“A total of 11 studies involving 1,593 participants and 3,285 paired measurements were included.”
From Comparison of point‑of‑care HbA1c devices with laboratory HPLC methods: A systematic review and meta‑analysis (2026) · cites this paper as [28]
The study description says this paper evaluates a point-of-care HbA1c analyzer against HPLC; it is not a systematic review or meta-analysis. Its comparison paragraph and Table 1 report 110 routine samples, not 11 studies, 1,593 participants, or 3,285 paired measurements. Page numbers are unavailable in our copy. (LLM, conf=0.89)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470 · see citing works
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360 · see citing works
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718 · see citing works
Executive Summary: Standards of Medical Care in Diabetes—2012
(2011) · Diabetes Care · doi:10.2337/dc12-s004 · Cited by 296 · see citing works
Impact of HbA1c Testing at Point of Care on Diabetes Management
Schnell, O., Crocker, J. B., & Weng, J. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816678263 · Cited by 139 · see citing works
Lenters‐Westra, E., & Slingerland, R. J. (2014) · Clinical Chemistry · doi:10.1373/clinchem.2014.224311 · Cited by 130 · see citing works
Evaluation of Three Hemoglobin A1c Point-of-Care Instruments
Criel, M., Jonckheere, S., & Langlois, M. (2016) · Clinical Laboratory · doi:10.7754/clin.lab.2015.150301 · Cited by 9 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Ortiz‐Martínez, M., Flores-DelaToba, R., González‐González, M., & Rito‐Palomares, M. (2021) · Biosensors · doi:10.3390/bios11120482 · Cited by 25 · see citing works
Wei, Y., Gu, M., Ren, Y., & Hu, Z. (2026) · Biomedical Reports · doi:10.3892/br.2026.2120 · Cited by 3 · see citing works
London, B., Hornung, L. N., Elder, D. A., & TELLEZ, S. E. (2026) · Journal of Diabetes Science and Technology · doi:10.1177/19322968261465344
- Authors
- Dupuy, A. M., Badiou, S., Bargnoux, A. S., Russello, J., & Cristol, J. P.
- Affiliations
- Hôpital Lapeyronie (FR)
- Centre National de la Recherche Scientifique (FR)
- Hôpital Saint Eloi (FR)
- Corresponding author
- Cristol, Jean Paul
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2018-11-27
- Volume
- 13
- Issue
- 1
- Pages
- 150-151
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC6313273
- OpenAlex
- W2902743570
- Cited by
- 2
- References
- 7
- Citations by year
- 2026: 1 · 2021: 1
- FWCI
- 0.20
- Type
- journal article
- Language
- en
- Update notices
- correction (2021-07-12)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Advanced Glycation End Products research
- Keywords
- point-of-care testing, HbA1c, diabetes monitoring, blood glucose monitoring
- MeSH terms
- Point-of-Care Testing, Chromatography, High Pressure Liquid, Hematologic Tests, Glycated Hemoglobin, Humans, Immunoassay, Reproducibility of Results
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review