CoChat

Multicenter Evaluation Study Comparing a New Factory-Calibrated Real-Time Continuous Glucose Monitoring System to Existing Flash Glucose Monitoring System

Open access
Ji, Linong, Guo, Lixin, Zhang, Junqing, Li, Yufeng, Chen, Zhiyan · 2023 · Journal of Diabetes Science and Technology

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

This study reports a clinical evaluation of AiDEX CGM system featuring a 14-day sensor, real-time glucose monitoring and factory-calibration. A multicenter, prospective, masked clinical study was conducted at with a total of 120 participants. Each participant wore 4 studied sensors and had one in-clinic visit for venous blood reference tests. 40 out of the 120 participants wore additional Abbott Libre sensors and performed at least 7 capillary BG tests daily for additional reference and comparison. Continuous glucose error grid analysis (CG-EGA) showed that AiDEX and Abbott Libre had good agreement with venous blood glucose, with 98.69% and 98.96% accurate readings, respectively. Overall MARD of AiDEX CGM systems was 9.08% when compared to venous blood reference and 10.1% when compared to finger capillary BG reference.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/19322968211037991

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 26

Metadata

Authors
Ji, L., Guo, L., Zhang, J., Li, Y., & Chen, Z.
Affiliations
  • Peking University People's Hospital (CN)
  • Beijing Hospital (CN)
  • Peking University First Hospital (CN)
  • Department of Endocrinology, Beijing Pinggu Hospital, Beijing, China
  • Microtech Medical (Hangzhou) Co., Ltd., Hangzhou, Zhejiang Province, China
Corresponding author
  • Ji, Linong
  • Guo, Lixin
Venue
Journal of Diabetes Science and Technology
Published
2021-08-11
Volume
17
Issue
1
Pages
208-213
ISSN
1932-2968 (ISSN-L)
OpenAlex
W3190509407
Cited by
26
References
9
Citations by year
2026: 4 · 2025: 6 · 2024: 7 · 2023: 7 · 2022: 1 · 2021: 1
FWCI
2.98
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Journal of Diabetes Science and Technology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Microtech Medical (Hangzhou) Co. Ltd.
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
Keywords
continuous glucose monitoring, factory calibration, real-time glucose monitoring, flash glucose monitoring, error grid analysis, mean absolute relative difference, venous blood glucose, capillary blood glucose, diabetes management
MeSH terms
Blood Glucose, Diabetes Mellitus, Type 1, Hematologic Tests, Humans, Prospective Studies, Blood Glucose Self-Monitoring, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multicenter Evaluation Study Comparing a New Factory-Calibrated Real-Time Continuous Glucose Monitoring System to Existing Flash Glucose Monitoring System. https://app.cochat.ai/papers/10.1177/19322968211037991
The paper
Ji, L., Guo, L., Zhang, J., Li, Y., & Chen, Z. (2023). Multicenter Evaluation Study Comparing a New Factory-Calibrated Real-Time Continuous Glucose Monitoring System to Existing Flash Glucose Monitoring System. Journal of Diabetes Science and Technology. https://doi.org/10.1177/19322968211037991

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.