Evaluating the Accuracy of Continuous Glucose-Monitoring Sensors
Open accessAbstract
OBJECTIVE—The objective of this study was to introduce continuous glucose–error grid analysis (CG-EGA) as a method of evaluating the accuracy of continuous glucose-monitoring sensors in terms of both accurate blood glucose (BG) values and accurate direction and rate of BG fluctuations and to illustrate the application of CG-EGA with data from the TheraSense Freestyle Navigator. RESEARCH DESIGN AND METHODS—We approach the design of CG-EGA from the understanding that continuous glucose sensors (CGSs) allow the observation of BG fluctuations as a process in time. We account for specifics of process characterization (location, speed, and direction) and for biological limitations of the observed processes (time lags associated with interstitial sensors). CG-EGA includes two interacting components: 1) point–error grid analysis (P-EGA) evaluates the sensor’s accuracy in terms of correct presentation of BG values and 2) rate–error grid analysis (R-EGA) assesses the sensor’s ability to capture the direction and rate of BG fluctuations. RESULTS—CG-EGA revealed that the accuracy of the Navigator, measured as a percentage of accurate readings plus benign errors, was significantly different at hypoglycemia (73.5%), euglycemia (99%), and hyperglycemia (95.4%). Failure to detect hypoglycemia was the most common error. The point accuracy of the Navigator was relatively stable over a wide range of BG rates of change, and its rate accuracy decreased significantly at high BG levels. CONCLUSIONS—Traditional self-monitoring of BG device evaluation methods fail to capture the important temporal characteristics of the continuous glucose-monitoring process. CG-EGA addresses this problem, thus providing a comprehensive assessment of sensor accuracy that appears to be a useful adjunct to other CGS performance measures.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Accuracy of CGM should be assessed from three viewpoints: the analytical viewpoint, clinical accuracy, and accuracy of the trend.
“Other authors have emphasized the need to assess accuracy from 3 viewpoints: the analytical viewpoint (i.e., evaluation of deviations between CGM values and blood glucose concentrations measured with a suitable comparator), the clinical accuracy, and the accuracy of the trend (i.e., the characterization of deviations between the glucose concentration rate of change and blood glucose concentrations”
From Importance of FDA-integrated continuous glucose monitors to ensure accuracy of continuous glucose monitoring (2025) · cites this paper as [30]
The continuous glucose-error grid comprises a point-error grid analysis for blood glucose measurement accuracy and a rate-error grid analysis for prediction capability.
“Because CGM systems also provide information on glucose fluctuations, the continuous glucose-error grid (CG-EGA) has been introduced comprising of (1) a point-error grid analysis (P-EGA) that evaluates the sensor accuracy in terms of accurate blood glucose measurements; and, (2) a rate-error grid analysis (R-EGA) that assesses the prediction capability of the sensor.77”
From Biocompatible Materials for Continuous Glucose Monitoring Devices (2013) · cites this paper as [77]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
On Information and Sufficiency
Kullback, S., & Leibler, R. A. (1951) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729694 · Cited by 20,193 · see citing works
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435 · see citing works
Self-citationParkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620 · see citing works
Distance measures for effective clustering of ARIMA time-series
Kalpakis, K., Gada, D., & Puttagunta, V. (2002) · Proceedings · doi:10.1109/icdm.2001.989529 · Cited by 444 · see citing works
Boyne, M. S., Silver, D. M., Kaplan, J., & Saudek, C. D. (2003) · Diabetes · doi:10.2337/diabetes.52.11.2790 · Cited by 404 · see citing works
Performance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., EINHORN, D. F., Kayne, D. M., Reed, J. H. C., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303 · see citing works
Feldman, B., Brazg, R., Schwartz, S. L., & Weinstein, R. L. (2003) · Diabetes Technology & Therapeutics · doi:10.1089/152091503322526978 · Cited by 184 · see citing works
Accuracy of Perceiving Blood Glucose in IDDM
Cox, D. J., Clarke, W. L., Gonder-Frederick, L. A., Pohl, S. L., Hoover, C. W., Snyder, A. L., Zimbelman, L. K., Carter, W. R., Bobbitt, S. A., & Pennebaker, J. W. (1985) · Diabetes Care · doi:10.2337/diacare.8.6.529 · Cited by 169 · see citing works
Self-citationUnderstanding Error Grid Analysis
Cox, D. J., Gonder-Frederick, L. A., Kovatchev, B. P., Julian, D. M., & Clarke, W. L. (1997) · Diabetes Care · doi:10.2337/diacare.20.6.911 · Cited by 73 · see citing works
Self-citationKlonoff, D. C. (2004) · Diabetes Care · doi:10.2337/diacare.27.3.834 · Cited by 56 · see citing works
Reservations on the Use of Error Grid Analysis for the Validation of Blood Glucose Assays
Gough, D., & Botvinick, E. L. (1997) · Diabetes Care · doi:10.2337/diacare.20.6.1034 · Cited by 35 · see citing works
Struzik, Z. R., & Siebes, A. P. J. M. (1999) · Proceedings - International Workshop on Database and Expert Systems Applications/Proceedings · doi:10.1109/dexa.1999.795160 · Cited by 34 · see citing works
Amitriptyline Treatment of Painful Diabetic Neuropathy: An Inadvertent Single-Patient Clinical Trial
Hoogwerf, B. J. (1985) · Diabetes Care · doi:10.2337/diacare.8.5.526 · Cited by 14 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
<i>In Silico</i> Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760 · see citing works
Self-citationBiosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660 · see citing works
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584 · see citing works
Non-invasive glucose monitoring technology in diabetes management: A review
Vashist, S. K. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.03.043 · Cited by 575 · see citing works
Biocompatible Materials for Continuous Glucose Monitoring Devices
Nichols, S. P., Koh, A., Storm, W. L., Shin, J. H., & Schoenfisch, M. H. (2013) · Chemical Reviews · doi:10.1021/cr300387j · Cited by 347 · see citing works
Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises
Vaddiraju, S., Burgess, D. J., Tomazos, I., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400632 · Cited by 285 · see citing works
Assessing Sensor Accuracy for Non-Adjunct Use of Continuous Glucose Monitoring
Kovatchev, B. P., Patek, S. D., Ortiz, E. A., & Breton, M. D. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0272 · Cited by 234 · see citing works
Self-citationMeasures of Accuracy for Continuous Glucose Monitoring and Blood Glucose Monitoring Devices
Freckmann, G., Pleus, S., Grady, M., Setford, S., & Levy, B. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818812062 · Cited by 202 · see citing works
In-Vivo Electrochemistry: What Can We Learn about Living Systems?
Wilson, G. S., & Johnson, M. A. (2008) · Chemical Reviews · doi:10.1021/cr068082i · Cited by 178 · see citing works
Visentin, R., Dalla Man, C., Kovatchev, B., & Cobelli, C. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0377 · Cited by 103 · see citing works
Self-citationPeng, B., Lu, J., Balijepalli, A. S., Major, T. C., Cohan, B. E., & Meyerhoff, M. E. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.05.014 · Cited by 103 · see citing works
Freckmann, G., Eichenlaub, M., Waldenmaier, D., Pleus, S., Wehrstedt, S., Haug, C., Witthauer, L., Jendle, J., Hinzmann, R., Thomas, A., et al. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231190941 · Cited by 86 · see citing works
Continuous Glucose Sensors: Continuing Questions about Clinical Accuracy
Clarke, W. L., & Kovatchev, B. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100510 · Cited by 71 · see citing works
Self-citationClinical Implications of Accuracy Measurements of Continuous Glucose Sensors
Bailey, T. S. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0050 · Cited by 60 · see citing works
Gosby, A. K., Lau, N. S., Tam, C. S., Iglesias, M. A., Morrison, C. D., Caterson, I. D., Brand-Miller, J., Conigrave, A. D., Raubenheimer, D., & Simpson, S. J. (2016) · PLoS ONE · doi:10.1371/journal.pone.0161003 · Cited by 51 · see citing works
Pemberton, J. S., Wilmot, E. G., Barnard‐Kelly, K., Leelarathna, L., Oliver, N., Randell, T., Taplin, C. E., Choudhary, P., & Adolfsson, P. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14962 · Cited by 44 · see citing works
Limits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials
Schrangl, P., Reiterer, F., Heinemann, L., Freckmann, G., & Del Re, L. (2018) · Biosensors · doi:10.3390/bios8020050 · Cited by 46 · see citing works
Klonoff, D. C., Gabbay, M., Moon, S. J., & Wilmot, E. G. (2025) · Journal of Diabetes Science and Technology · doi:10.1177/19322968241250357 · Cited by 36 · see citing works
Ji, L., Guo, L., Zhang, J., Li, Y., & Chen, Z. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211037991 · Cited by 26 · see citing works
Performance of a new real‐time continuous glucose monitoring system: A multicenter pilot study
Zhou, J., Zhang, S., Li, L., Wang, Y., Lu, W., Sheng, C., Li, Y., Bao, Y., & Jia, W. (2018) · Journal of Diabetes Investigation · doi:10.1111/jdi.12699 · Cited by 22 · see citing works
Tian, T., Aaron, R. E., Kohn, M. A., & Klonoff, D. C. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231214281 · Cited by 16 · see citing works
Performance Assessment of Three Continuous Glucose Monitoring Systems in Adults With Type 1 Diabetes
Kölle, J., Eichenlaub, M., Mende, J., Link, M., Vetter, B., Safary, E., Pleus, S., Haug, C., & Freckmann, G. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231159657 · Cited by 9 · see citing works
- Authors
- Kovatchev, B. P., Gonder-Frederick, L. A., Cox, D. J., & Clarke, W. L.
- Affiliations
- University of Virginia Health System (US)
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2004-08-01
- Volume
- 27
- Issue
- 8
- Pages
- 1922-1928
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2116146322
- Cited by
- 312
- References
- 13
- Citations by year
- 2026: 8 · 2025: 10 · 2024: 11 · 2023: 7 · 2022: 5 · 2021: 8 · 2020: 9 · 2019: 12 · 2018: 12 · 2017: 13 · 2016: 10 · 2015: 15 · 2014: 15 · 2013: 26 · 2012: 23
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk051562-23)
- National Institute of Diabetes and Digestive and Kidney Diseases (R01DK 51562, RO1 DK 51562)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Keywords
- continuous glucose monitoring, sensor accuracy, error grid analysis, blood glucose fluctuation, hypoglycemia detection, time delay, self-monitoring of blood glucose
- MeSH terms
- Adult, Aged, Blood Glucose, Clinical Trials as Topic, Diabetes Mellitus, Type 1, Female, Humans, Male, Middle Aged, Reproducibility of Results, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review