Insulin Pump Alarms During Adverse Events: A Qualitative Descriptive Study
Open accessAbstract
OBJECTIVE: Explore alarm signals cited in insulin pump-associated adverse events (AEs), describe the clinical consequences and other root cause informing remarks that cooccurred with the alarm signals, and identify opportunities for improvements to patient education, instructional materials, and alarm systems to prevent future AEs. RESEARCH DESIGN AND METHODS: We explored the type, frequency, and associated clinical consequences of alarm signals cited in a pre-coded data set of 2294 insulin pump-associated AEs involving the MiniMed 670G, MiniMed 630G, and t:slim X2. We also explored the clinical consequences and other root cause informing remarks that cooccurred with the top 10 most frequently cited alarm signals. RESULTS: Overall, 403 AEs narratives cited at least one alarm signal. Of the 40 unique alarm signals cited, 42.5% were "alarms," 25.0% were "alerts," and 32.5% were not referenced in the instructional materials packaged with the corresponding pump. The top 10 most frequently cited alarm signals included two obstruction of flow alarms, which accounted for 49.9% of all AEs citing at least one alarm, and two unreferenced alarms. The most frequent cooccurring root cause informing remark varied across the top 10 alarm signals and revealed valuable insight into why these alarms may have occurred. CONCLUSIONS: Our findings demonstrate the value of analyzing alarm signals cited in insulin pump-associated AEs and reveal multiple opportunities for providers to educate patients on how to respond to alarm signals and manage their pumps to avoid AEs, and for insulin pump manufacturers to update instructional materials and improve alarm systems to support appropriate patient response.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A recent analysis of MAUDE database narratives confirms that the most frequent pump alarms associated with adverse events are for occlusion or insulin flow blocked.
“A recent analysis of MAUDE database narratives confirms that the most frequent pump alarms associated with adverse events are for “occlusion” or “insulin flow blocked” [11].”
From Performance of a Continuous Subcutaneous Insulin Infusion (CSII) Pump With Acoustic Volume and Flow Sensing in Simulated High-Consequence Situations (2024) · cites this paper as [11]
The most frequent pump alarms associated with adverse events in the FDA MAUDE database are for "occlusion" and "insulin flow blocked".
“Adverse event analysis from the FDA MAUDE database confirms that the most frequent pump alarms associated with adverse events are for “occlusion” and “insulin flow blocked” [11].”
From Performance of a Continuous Subcutaneous Insulin Infusion (CSII) Pump With Acoustic Volume and Flow Sensing in Simulated High-Consequence Situations (2024) · cites this paper as [11]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493 · see citing works
Insulin pump-associated adverse events in children and adolescents–a prospective study
Wheeler, B. J., Heels, K., Donaghue, K. C., Reith, D. M., & Ambler, G. R. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0388 · Cited by 64 · see citing works
Insulin Pump Occlusions: For Patients Who Have Been Around the (Infusion) Block
Klonoff, D. C., Freckmann, G., & Heinemann, L. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817700545 · Cited by 41 · cited 1× · see citing works
“7,17,18 For example, we found that only a small proportion of the AEs involving the MiniMed 670G and 630G pumps that cited a bent cannula also mentioned an insulin flow blocked alarm (14%).”
Flagged first, then by citations
Research works printed but not linked: 7
- Ross PL, Milburn J, Reith DM, Wiltshire E, Wheeler BJ. Clinical review: insulin pump-associated adverse events in adults and children. Acta Diabetol. 2015;52(6):1017-1024. doi:10.1007/s00592-015-0784-2 · DOI
- Estock JL, Codario RA, Keddem S, Zupa MF, Rodriguez KL, DiNardo MM. Insulin pump-associated adverse events: a qual- itative descriptive study of clinical consequences and poten- tial root causes. Diabetes Technol Ther. 2023;25:343-355. doi:10.1089/dia.2022.0498 · DOI
- Zhang Y, Jones PL, Klonoff DC. Second insulin pump safety meeting: summary report. J Diabetes Sci Technol. 2010;4(2):488-493. doi:10.1177/193229681000400232 · DOI
- Heinemann L, Fleming GA, Petrie JR, Holl RW, Bergenstal RM, Peters AL. Insulin pump risks and benefits: a clinical appraisal of pump safety standards, adverse event report- ing and research needs. A joint statement of the European Association for the Study of Diabetes and the American Diabetes Association Diabetes Technology Working Group. Diabetologia. 2015;58(5):862-870. doi:10.1007/s00125-015- 3513-z · DOI
- van Bon AC, Dragt D, DeVries JH. Significant time until cath- eter occlusion alerts in currently marketed insulin pumps at two basal rates. Diabetes Technol Ther. 2012;14(5):447-448. doi:10.1089/dia.2011.0259 · DOI · Paper page
- Shivers JP, Mackowiak L, Anhalt H, Zisser H. "Turn it off!": diabetes device alarm fatigue considerations for the present and the future. J Diabetes Sci Technol. 2013;7(3):789-794.
- Roberts R, Walsh J, Heinemann L. Help! someone is beeping . . . J Diabetes Sci Technol. 2014;8(4):627-629. doi:10.1177/1932296814532882 · DOI
Cited by
Sorted by citations
Giza, S., Kotanidou, E. P., Tsinopoulou, V. R., Poukoulidou, T., Ntouma, S., & Galli-Tsinopoulou, A. (2025) · Children · doi:10.3390/children12121668 · Cited by 7 · see citing works
Butterfield, R. D., & Sims, N. M. (2024) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2024.3408092 · Cited by 6 · see citing works
“Adverse event analysis from the FDA MAUDE database confirms that the most frequent pump alarms associated with adverse events are for “occlusion” and “insulin flow blocked” [11].”
Background
- Authors
- Estock, J. L., Codario, R. A., Zupa, M. F., Keddem, S., & Rodriguez, K. L.
- Affiliations
- VA Pittsburgh Healthcare System (US)
- University of Pittsburgh (US)
- Philadelphia VA Medical Center (US)
- Venue
- Journal of Diabetes Science and Technology
- Publisher
- SAGE Publications
- Published
- 2023-10-31
- Volume
- 19
- Issue
- 3
- Pages
- 739-748
- ISSN
- 1932-2968 (ISSN-L)
- PMC
- PMC12035310
- OpenAlex
- W4388033229
- Cited by
- 4
- References
- 3
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2
- FWCI
- 1.35
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Diabetes Science and Technology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Veterans Affairs Veterans Integrated Service Networks (VISN) 4 (EstockCCDF19)
- Topics
- Health Sciences › Health Professions › Emergency Medical Services › Patient Safety and Medication Errors
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- continuous glucose monitoring, MiniMed 670G, root cause analysis, patient education, alarm system design
- MeSH terms
- Diabetes Mellitus, Type 1, Equipment Failure, Female, Humans, Hypoglycemic Agents, Insulin, Insulin Infusion Systems, Male, Patient Education as Topic, Qualitative Research, Clinical Alarms
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review