The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index; 2 of the 132 sources its claims cite were checked for support.
Can Glucose Alarm Fatigue Threaten the Absolute Clinical Benefit of Continuous Glucose Monitoring in Optimal Glucose Management in Children and Adolescents with Type 1 Diabetes? A Narrative Review
Open accessAbstract
Technology has brought about a revolution in the management of type 1 diabetes (T1D). The adoption of continuous glucose monitoring (CGM) and insulin pump therapy in the everyday life of children and adolescents with T1D is a real innovation and the most promising choice for optimizing glycemic control in this population. The incorporation of an alarm system, including notifications, alerts and alarms and warning patients and their parents about glucose levels and upcoming events interfering with safety, is an invaluable additional tool for better targeting euglycemia. However, in parallel with the clinical benefits of alarm systems in ameliorating metabolic control parameters, alarm fatigue was recorded as a phenomenon, negatively affecting the everyday lives of patients and their caregivers, and as a cause for rejecting or abandoning CGM or pump therapy treatment. There are a few data concerning the frequency, consequences and methods of eliminating alarm fatigue among children. As a result, we have conducted a narrative review to briefly present the basic philosophy of the existing CGM alarm systems and their positive effect on glycemic management, and focus on alarm fatigue; definition, frequency, effect on quality of life and sleep, not only of T1D pediatric patients but also of their families, and methods of elimination. Efforts to achieve a more reliable and accurate alarm system and educate on adapting personalized limits and positively interpreting them may protect the T1D pediatric population from alarm fatigue and prevent rejection or incomplete use of CGM and insulin pump as the therapeutic choice, ensuring the best glycemic control.
Overview
CoChat Summary
TL;DR
This narrative review argues that CGM/pump/HCL alarms improve glycemic management in children and adolescents with type 1 diabetes, but alarm fatigue is common and can undermine adherence, quality of life, and sleep. The authors conclude that despite this problem, alarm fatigue is “not able to threaten the undeniable positive effect on glycemic control.”
Key findings
- The search identified 1496 records; after removing 915 duplicates and screening, the review included 30 articles.
- Reported alarm-fatigue frequency was highly variable: 0 in some studies, 26–50% in others, and technology discontinuation used as an indirect marker ranged from 12% to 62%.
- In the only study that estimated parental sleep, alarm-fatigue frequency was 60%.
- A prospective observational study of 47 children and adolescents found that switching from FreeStyle Libre to FreeStyle Libre 2 for 14 days increased time in range (TIR) and reduced time above range (TAR), weekly hypoglycemic events, and coefficient of variation.
Methods
- Narrative review of literature published from 1 January 2000 to 30 September 2025.
- Database searched: PubMed/Medline; included studies of children/adolescents with T1D and/or their parents/caregivers using CGM, insulin pump, or HCL systems.
- Included observational and qualitative studies in English; excluded adult-only studies, type 2 diabetes, case reports/series, editorials, and letters. Full texts were reviewed and findings synthesized narratively.
Limitations
- The paper states it is a narrative review, and it notes that prior data on alarm fatigue were “scarce and scattered”; it does not report a formal meta-analysis or quantitative pooled estimate.
- The evidence base was heterogeneous: studies varied in how alarm fatigue was defined or measured, and many did not record frequency directly; this limits comparability (stated in the paper).
- Evident from the text: the review is restricted to PubMed/Medline and English-language studies, so relevant evidence outside those bounds may have been missed.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
2 Valid · 0 Not valid · 97 Not checked · 16 Own results and interpretations
The sources with a verdict support this claim; the rest weren’t checked yet, have no full text we could read, or their verdicts aren’t rated yet.
In the paper
“Among 85 children and adolescents between 5 and 18 years old with T1D, alarm fatigue was found to be the main reason for discontinuing CGM [ 43 ], or at least one of the reasons [ 32 , 67 ].”
What the sources say
- Not checked yetcites [32] Barnard, 2016, Impact of Type 1 Diabetes Technology on Family Members/Significant Others of People With Diabetes, J. Diabetes Sci. Technol. source
- Supportedcites [67] Choudhary, 2018, Hypoglycaemia in type 1 diabetes: Technological treatments, their limitations and the place of psychology, Diabetologia source
The Treatment adherence section (Limitations of technology) states that in a representative paediatric cohort, reasons for discontinuing CGM included 'too many alarms' (27%), i.e. one of several reasons, and the Alarm fatigue section states that 'many individuals give alarm fatigue as a reason for discontinuing sensor use'. The review reports these as findings of the cohort it cites (ref 69), which is sufficient for a review source; our copy does not give the sample size or 5-18 age range, but the paraphrase attributed here — that among children and adolescents alarm fatigue was at least one reason for CGM discontinuation — is stated. (LLM, conf=0.85)
plainstates a causen = 85- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
None of the sources cited for this claim have been checked yet.
In the paper
“Studies recorded the impact of alarm fatigue among patients [ 18 , 29 , 31 , 33 , 34 , 36 , 43 , 44 , 45 , 47 , 49 , 53 , 55 ], their parents [ 22 , 27 , 32 , 35 , 38 , 42 , 46 , 50 ] or both [ 25 , 37 , 39 , 40 , 41 , 48 , 51 , 52 , 54 ].”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“In the only study [ 48 ] that estimated parental sleep, alarm fatigue frequency was rather high (60%).”
What the sources say
- Not checked yetcites [48] Macaulay, 2020, Sleep and Night-time Caregiving in Parents of Children and Adolescents with Type 1 Diabetes Mellitus—A Qualitative Study, Behav. Sleep Med. source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“In a study, among CGM ex-users, 50% reported too many alarms as the cause of CGM discontinuation.”
What the sources say
- Not checked yetcites [43] Farfel, 2020, Executive Functions and Adherence to Continuous Glucose Monitoring in Children and Adolescents with Type 1 Diabetes, Diabetes Technol. Ther. source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“Among 85 children and adolescents between 5 and 18 years old with T1D, alarm fatigue was found to be the main reason for discontinuing CGM [ 43 ], or at least one of the reasons [ 32 , 67 ].”
What the sources say
- Not checked yetcites [43] Farfel, 2020, Executive Functions and Adherence to Continuous Glucose Monitoring in Children and Adolescents with Type 1 Diabetes, Diabetes Technol. Ther. source
hedgedstates a causen = 85- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
47 more claims
Create a free account to see all 115 claims and to verify the 130 references still open.
- Probably not a substantial claim. 28
- It may state two separate claims as one. 44
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
“There were two studies being conducted with parental sleep [ 48 ] and QoL [ 42 ].”
“Overnight awakening due to CGM alerts and notifications was also reported in two other studies, performing qualitative narrative analysis of CGM and evaluating its impact on parental sleep [ 27 , 35 ].”
Citations
Cites
Maiorino, M. I., Signoriello, S., Maio, A., Chiodini, P., Bellastella, G., Scappaticcio, L., Longo, M., Giugliano, D., & Esposito, K. (2020) · Diabetes Care · doi:10.2337/dc19-1459 · Cited by 364
Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry
Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., et al. (2014) · Diabetes Care · doi:10.2337/dc14-0303 · Cited by 318 · cited 2×
“Studies recorded the impact of alarm fatigue among patients [18,29,31,33,34,36,43– 45,47 ,49 ,53 , 55 ], their parents [22 ,27 ,32,35,38,42,46, The main reasons responsible for alarm fatigue concerned either everyday life [22,25,29,31,33,34,37,39,41,43,45,46,49,51,52] or sleep [18,25,27,29,31–38,…”
for the T1D Exchange Clinic Network, T. D. I., Sherr, J. L., Hermann, J. M., Campbell, F., Foster, N. C., Hofer, S. E., Allgrove, J., Maahs, D. M., Kapellen, T. M., Holman, N., et al. (2016) · Diabetologia · doi:10.1007/s00125-015-3790-6 · Cited by 237
One year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215 · cited 1×
“Studies recorded the impact of alarm fatigue among patients [18,29,31,33,34,36,43– 45,47 ,49 ,53 , 55 ], their parents [22 ,27 ,32,35,38,42,46, The main reasons responsible for alarm fatigue concerned either everyday life [22,25,29,31,33,34,37,39,41,43,45,46,49,51,52] or sleep [18,25,27,29,31–38,…”
Pickup, J. C., Ford Holloway, M., & Samsi, K. (2015) · Diabetes Care · doi:10.2337/dc14-1855 · Cited by 189
Bidargaddi, N., Almirall, D., Murphy, S., Nahum-Shani, I., Kovalcik, M., Pituch, T., Maaieh, H., & Strecher, V. (2018) · JMIR mHealth and uHealth · doi:10.2196/10123 · Cited by 189
Lawton, J., Blackburn, M., Allen, J., Campbell, F., Elleri, D., Leelarathna, L., Rankin, D., Tauschmann, M., Thabit, H., & Hovorka, R. (2018) · BMC Endocrine Disorders · doi:10.1186/s12902-018-0239-1 · Cited by 174
Alva, S., Bailey, T., Brazg, R., Budiman, E. S., Castorino, K., Christiansen, M. P., Forlenza, G., Kipnes, M., Liljenquist, D. R., & Liu, H. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820958754 · Cited by 164
Messer, L. H., Berget, C., Vigers, T., Pyle, L., Geno, C., Wadwa, R. P., Driscoll, K. A., & Forlenza, G. P. (2020) · Pediatric Diabetes · doi:10.1111/pedi.12971 · Cited by 161
“Turn it Off!”: Diabetes Device Alarm Fatigue Considerations for the Present and the Future
Shivers, J. P., Mackowiak, L., Anhalt, H., & Zisser, H. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700324 · Cited by 158
Research works printed but not linked: 3
- Varughese, 2021, The Value of Optional Alarms in Continuous Glucose Monitoring Devices: A Survey on Patients and their Physicians, Diabetes Stoffwechs. Herz, 30, 231
- Aljuhani, 2024, Comparing Real-Time Continuous Glucose Monitoring to Self-Monitoring of Blood Glucose: Advantages and Limitations for Children and Adolescents With Type 1 Diabetes, Cureus, 16, e51496
- Kaylor, 2022, Alarm fatigue and sleep deprivation in carers of children using continuous glucose monitors, Diabetes Care Child. Young People DCCYP, 11, 103
Cited by
Wang, Q., Pan, F., Li, B., Liu, X., & Zhang, J. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1862387 · Cited by 1
Advances in diabetes technology: clinical implications, limitations, and future perspectives
Apostolopoulou, M., & Effraimidis, G. (2026) · HORMONES · doi:10.1007/s42000-026-00797-w · Cited by 2
Ayhan, D. B., & Özdemir, S. (2026) · Journal of Pediatric Nursing · doi:10.1016/j.pedn.2026.08.011 · Cited by 1
Dennis, C., & Bouhairie, V. E. (2026) · Diabetes Therapy · doi:10.1007/s13300-026-01894-0
Insulin pens and the digital ecosystem
JENDLE, J. H., Adolfsson, P., Cardona‐Hernandez, R., Crenier, L., Molfetta, S. D., Ehrmann, D., Giorgino, F., Haluzík, M., Hirsch, I. B., Irace, C., et al. (2026) · Diabetologia · doi:10.1007/s00125-026-06858-4 · Cited by 1
Metadata
- Authors
- Giza, S., Kotanidou, E. P., Tsinopoulou, V. R., Poukoulidou, T., Ntouma, S., & Galli-Tsinopoulou, A.
- Affiliations
- Aristotle University of Thessaloniki (GR)
- Unit of Pediatric Endocrinology, Diabetes and Metabolism–Collaborative Sweet Center, 2nd Department of Paediatrics, School of Medicine, Faculty of Health Sciences, Aristotle University of Thessaloniki, AHEPA University General Hospital, Stilponos Kyriakidi 1, 54636 Thessaloniki, Greece
- ORCID
- Venue
- Children
- Publisher
- MDPI AG
- Published
- 2025-12-08
- Volume
- 12
- Issue
- 12
- Pages
- 1668
- ISSN
- 2227-9067 (ISSN-L)
- PMC
- PMC12731774
- OpenAlex
- W4417120559
- Cited by
- 7
- References
- 75
- Citations by year
- 2026: 7
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Children (publishedVersion, cc-by)
- Preprints.org (acceptedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- alarm fatigue, continuous glucose monitoring, type 1 diabetes, children and adolescents, insulin pump therapy, glycemic control, sleep, quality of life, treatment discontinuation, normoglycemia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Can Glucose Alarm Fatigue Threaten the Absolute Clinical Benefit of Continuous Glucose Monitoring in Optimal Glucose Management in Children and Adolescents with Type 1 Diabetes? A Narrative Review. https://app.cochat.ai/papers/10.3390/children12121668
- The paper
- Giza, S., Kotanidou, E. P., Tsinopoulou, V. R., Poukoulidou, T., Ntouma, S., & Galli-Tsinopoulou, A. (2025). Can Glucose Alarm Fatigue Threaten the Absolute Clinical Benefit of Continuous Glucose Monitoring in Optimal Glucose Management in Children and Adolescents with Type 1 Diabetes? A Narrative Review. Children. https://doi.org/10.3390/children12121668
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
